tfs210c.doc version 1.6 09.08.2001 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 210 C 1/5 ______________________________________________________________________________________________________ Measurement Condition 23 C 0 dBm Ambient temperature: Input power level: Terminating impedances * Input: Output: 295 295 || 1,15 pF || 1,15 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 210 C is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae . The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss a e. The nominal frequency fN is fixed on 210,38 MHz without tolerance. The given values for the relative attenuation a rel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. D a t a typ. Value Insertion Loss (Reference level) ae = amin Nominal Frequency fN 3 dB - Band Width BW Relative Attenuation fN ± 0 kHz ... fN ± 13 fN ± 13 kHz ... fN ± 15 kHz kHz fN fN fN fN fN fN kHz kHz MHz MHz MHz ± 60 ± 60 ± 120 + 420 + 1,25 - 420 kHz kHz ... kHz ... kHz ... MHz ... kHz ... fN fN fN fN fN ± 120 ± 420 + 1,25 + 2,05 2,05 Group Delay Distortion fN ± 0 kHz ... fN ± 11 arel Variation/ Limitation 6,6 dB max. 8,0 dB 54 210,38 MHz kHz min. 30 23 - kHz max. 1,5 dB max. 3 dB dB min. min. min. min. min. min. 20 20 40 50 55 60 dB dB dB dB dB dB max. 9 µs GDD kHz - Temperature Coefficient of Frequency TCf ** Frequency Inversion Temperature T0 Operating Temperature Range - 0,036 ppm/K + 25 °C 2 - 10°C ... + 60°C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as **) reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz) Generated: Checked / approved: ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs210c.doc version 1.6 09.08.2001 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 210 C 2/5 ______________________________________________________________________________________________________ Construction and Pin Configuration (All dimensions in mm) 1 2 3 4 5 6 7 8 9 10 S 210 C N32 Datecode Output Ground Ground Ground Ground Ground Input Ground Ground Ground Datecode L M N ... 50 Year + week 1999 2000 2001 test circuit 1 L1 L2 7 1 C1 C2 2,3,4,5,6,8, 9,10,11,12 50 test circuit 2 C1 C2 1 7 L1 L2 2,3,4,5,6,8, 9,10,11,12 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs210c.doc version 1.6 09.08.2001 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 210 C 3/5 ______________________________________________________________________________________________________ Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 1,5 mm or 20g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each. / 10 cycles DIN IEC 68 part 2 14 Test N 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer Tape (all dimensions in mm) W : 16 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,5 + 0,5 D1 : 1,5 E : 1,75 ± 0,1 F : 7,5 ± 0,1 G (min) : P2 : 2 ± 0,05 : 8 ± 0,1 D1(min) : 1,5 Ao 5,5 Bo EMBOSSED CARRIER TAPE Do Po P2 E Ao : : F D1 13,4 ± 0,1 W Bo 0,6 P1 3000 min 300 mm min 500 mm min 300 mm G P1 ± 0,1 7,5 ± 0,1 COVER TAPE W 2 Reel (all dimensions in mm): A : 330 W1 : W2 (max) : 16,4 +2 22,4 N (min) : 50 C : 13 + 0,5 / - 0,2 C A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs210c.doc version 1.6 09.08.2001 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 210 C 4/5 ______________________________________________________________________________________________________ Air reflow Temperature Conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs210c.doc version 1.6 09.08.2001 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 210 C 5/5 ______________________________________________________________________________________________________ History Version Reason of Changes Name Date 1.6 Add History Add 50 test circuit Correct Tape and reel information Herrler 09.08.2001 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.