Version 4.0 tfs199d.doc VI TELEFILTER Filter specification 15.02.2001 TFS 199 D 1/5 Measurement condition Ambient temperature: Input power level: terminating impedances 20 ... 25 5±2 input: output: °C dBm 740 Ω || -7.9pF single ended 880 Ω || -6.2pF single ended Characteristics Remark: Reference level for the relative attenuation arel of the TFS 199 D is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 0,5 dB filter attenuation level relative to the insertion loss ae. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss fN Relative attenuation fN - 100 kHz ... fN + arel 80 30 ± 600 + 800 + 17 max. ae = amin Nominal frequency fN fN fN fN fN limit 100 MHz ... fN 30 MHz ... fN - 800 kHz ... fN ± 800 kHz ... fN + 17 kHz ... fN + 80 - 199,0 MHz kHz max. MHz kHz kHz MHz MHz min. min. min. min. min. Group delay ripple GD fC - 100 kHz ... fC + 100 kHz - Input power level short test standard operation Permissible DC voltage 7,0 dB - 0,5 dB 30 25 20 25 35 dB dB dB dB dB max. 500 ns max. + 18 max. + 10 dBm dBm max. V 10 -35 °C ... + 85 °C -35 °C ... + 85 °C Operating temperature range Storage temperature range Temperature coefficient TC - 0,036 ppm/K² Frequency inversion temperature To 23 °C Generated: Checked / approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 0075 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 4.0 tfs199d.doc VI TELEFILTER Filter specification 15.02.2001 TFS 199 D 2/5 Construction and pin connection (All dimensions in mm) 6 TFS199D M30 6,50 +/-0,20 13,31 +/-0,20 10 1 2 3 4 5 6 7 8 9 Datecode 1,80+/-0.2 5 1 Datecode: K L M Year+week 1998 1999 2000 ... 1,9+/-0.2 1,02+/-0.2 10 Input RF Return Ground Ground Ground Output Output RF Return Ground Ground Ground Input 1,91+/-0.2 7,62+/-0.2 50 Ω test circuit L1 L3 10 Input 50 Ohm 5 Output SAW L4 L2 50 Ohm 6 1 2,3,4,7,8,9 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 0075 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 4.0 tfs199d.doc VI TELEFILTER 15.02.2001 Filter specification TFS 199 D 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer Tape (all dimensions in mm) W Po Do E : : : : 24 ± 0,3 4 ± 0,1 1,5 + 0,1 1,75 ± 0,1 F : G (min) : 11,5 ± 0,1 0,60 P2 : P1 : D1(min) : Ao : 2 12 1,5 7,1 ± 0,1 ± 0,1 13,9 21,5 ± 0,2 ± 0,1 Bo Ct : : 2000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Do Po P2 E Ao F D1 Ct W Bo G ± 0,2 P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 24,40 +2,0 30,4 60 C C : 13 A ± 0,5/-0.2 N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 0075 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 4.0 tfs199d.doc VI TELEFILTER 15.02.2001 Filter specification TFS 199 D 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 0075 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 4.0 tfs199d.doc VI TELEFILTER Filter specification 15.02.2001 TFS 199 D 5/5 History Version Reason of Changes Name Date 1.0 2.0 Steiner Steiner 05.11.1999 16.06.2000 3.0 -generation of specification - change to single ended pinning - new impedances according to single ended design - change attenuation from 30 dB to 25 dB at fN- 30MHz...fN-800kHz fN+800kHz...fN+17MHz - change the filter name to TFS199D Steiner 04.07.2000 3.1 - correct the package dimensions Steiner 28.07.2000 4.0 - change the insertion loss limit from max. 8dB to max. 7dB as agreed with the customer Steiner 15.02.2001 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 0075 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.