VECTRON TFS125C

Tfs125C.doc
version 1.2
VI TELEFILTER
12.07.00
Filter Specification
TFS 125C
1/5
Measurement condition
Ambient temperature TA:
Input power level:
Terminating impedances at fc:
23 °C
0 dBm
input:
output:
605 Ω  -11 pF
620 Ω  -11 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 125C is the maximum of the pass band attenuation amax. The maximum of the pass
band attenuation amax is defined as the insertion loss ae. The centre frequence fc is the arithmetic mean value of the upper and lower frequencies
at the 1 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 125 MHz without tolerance. The given values
for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is
shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre
frequency fc.
Data
typ. value
tolerance / limit
Insertion loss (Reference level)
ae
max.
min.
Nominal frequency
fN
-
Centre frequency
fc
125,0
dB Passband ripple
within ± 150 kHz
Relative attenuation
arel
fN
..... fN ± 150
fN ± 0,4 MHz...fN ± 0,6
fN ± 0,6 MHz...fN ± 1,2
fN ± 1,2 MHz...fN ± 1,8
fN ± 1,8 MHz...fN ±3,4
fN ± 3,4 MHz...fN ±9,5
fN ± 9,5 MHz.. fN ±13
fN ± 13 MHz...fN +450
KHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
125,0
-
± 150 kHz
1,25
max.
min.
min.
min.
min.
min.
min.
min.
1,25
2,0
.8,0
20,0
25,0
30,0
43,0
55,0
max.
1,7
µs
max. 150,0
ns
max.
IP3 ***)
min.
Input power level:
MHz
min.
VSWR:
Operating temperature range
Temperature coefficient of frequency ( Tcf ) ****)
Frequency inversion temperature To
dB
dB
MHz
Group delay **)
Group delay rippel **) within
8,0
5,0
dB
dB
dB *)
dB
dB
dB
dB
dB
dB
2,3: 1
60,0
dB
- 10 °C ... + 85 °C
T.B.D
T.B.D
max.
10,0
dBm
*) The rejection is relative to the point of maximum insertion at centre frequency
**) measured with smoothing; smoothing aperture ≤ 30 KHz
***) modulation signals: fN and fN-28 MHz each of 10 dBm
****) ∆fc(Hz) = Tcf(ppm/K²) x (To - TA) ² x fCAT (MHz)
Generated:
Sabah
Checked/Approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs125C.doc
version 1.2
VI TELEFILTER
12.07.00
Filter Specification
TFS 125C
2/5
Construction and pin connection
(All dimensions in mm)
13.3
10
11
12
9
7
8
TFS 125C
M46
1
2
3
1
2
3
4
5
6
7
8
9
10
11
12
6
6.5 MAX.
5
4
10
Datecode
Ground
Ground
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Ground
Input
Input RF Return
Date code: Year+week
K
1998
L
1999
M
2000
N
2001
......
50 Ω matching network:
L2
L1
11
Input
50 Ohm
5
Output
SAW
C1
C2
50 Ohm
6
12
1,2,3,4,7,8,9,10
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs125C.doc
version 1.2
VI TELEFILTER
12.07.00
Filter Specification
TFS 125C
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
Do
E
:
:
:
:
24
± 0,3
4
± 0,1
1,5 + 0,1
1,75 ± 0,1
F
:
G (min) :
11,5 ± 0,1
0,60
P2
:
P1
:
D1(min) :
2
12
1,5
± 0,1
± 0,1
± 0,2
± 0,2
1700
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
F
D1
CT
W
Bo
G
Ao
Bo
:
:
7,1
13,9
CT
:
21,5 ± 0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
24,40 +2,0
30,4
60
C
C
:
13
A
± 0,5/-0.2
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the left side of the tape.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs125C.doc
version 1.2
VI TELEFILTER
12.07.00
Filter Specification
TFS 125C
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Tfs125C.doc
version 1.2
VI TELEFILTER
Filter Specification
12.07.00
TFS 125C
5/5
History
Version
Reason of Changes
1.0
1.1
- generation of specification according to hudson specification
Sabah
- correction according to customer specification (Nokia)
Sabah
- IP3: instead of ‘No statement’ is ≥ 60 dBm
- VSWR (max): instead of ≤ 2.0:1 is ≤ 2.3:1
min. 55 dB
- Rejection (f ≥ fN ± 13000 KHz): instead of min. 60 dB is
- Operational temperature range changed from -10 .... 80 °C to -10 ..... 85 °C
- The sprocket holes: instead of the right side of the tape is on the left
side of the tape (according to customer requirement, e mail from: 7. Juli.00)
Sabah
1.2
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Name
Date
07.10.1999
27.03.2000
12.07.2000
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information