tfs210f.doc VI TELEFILTER Filter specification version 2.0 28.07.2000 TFS 210 F 1/5 Measurement Condition Ambient Temperature: Input Power Level: Source impedance: Load impedance: Terminating impedances: input: output: 23 °C 0 dBm 50 Ω single ended 50 Ω single ended 480 Ω || -9,8pF 1030 Ω || -5,95pF Characteristics Remark: Reference level for the relative attenuation arel is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The nominal frequency fN is fixed to 210,38 MHz. The given values for the relative attenuation arel and for the phase ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo. Data typ. Value Limit Insertion Loss (Reference level) ae = amin 8 Nominal Frequency fN - 5 dB - Bandwidth BW 1,6 MHz min. 1,26 MHz Relative Attenuation arel - max. 5 fN ± 0,63 MHz fN ± 1,25 MHz ... fN ± 20 MHz dB max. 45 45 40 dB 210,38 MHz - fN - 1,25 MHz fN + 1,25 MHz fN ± 2,05 MHz 10 min. dB dB dB min. min. min. 35 35 37 dB 35 dB dB dB dB Pass Band Ripple fN ± 0,300 MHz - 0,3 dB max. 1,2 dB Phase linearity fN ± 0,300 MHz fN ± 0,630 MHz - ϕ 0,5 °rms 2,9 °rms max. max. 1,5 °rms 3,75 °rms Operating Temperature Range - 30 °C ... + 80 °C Generated: Checked / approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs210f.doc VI TELEFILTER Filter specification version 2.0 28.07.2000 TFS 210 F 2/5 Construction and pin connection 8 9 10 6 Datecode 5 S 210 F M30 1 1 4 3 3 10 4 9 5 8 6 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Output Output RF Return Ground Ground Ground Input Input RF Return Datecode: K L M ... Year+week 1998 1999 2000 50 Ω single ended test circuit L2 L1 9 Input 50 Ohm 4 Output SAW C1 50 Ohm C2 1,2,3,5,6,7,8 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs210f.doc VI TELEFILTER Filter specification version 2.0 28.07.2000 TFS 210 F 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing: Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer Tape (all dimensions in mm) W Po Do : : : 16 4 1,5 E F : : 1,75 ± 0,1 7,5 ± 0,1 G (min) : P2 : P1 : 0,6 2 ± 0,1 8 ± 0,1 3000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE ± 0,3 ± 0,1 + 0,5 Do Po P2 E Ao F D1 W Bo Ct G D1(min) : Ao : 1,5 5,5 ± 0,1 Bo : 7,5 ± 0,1 Ct : 13,5+/-0,1 P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 16,4 +2 22,4 50 C C : 13 + 0,5 - 0,2 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the sprocket holes. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs210f.doc VI TELEFILTER Filter specification version 2.0 28.07.2000 TFS 210 F 4/5 Air Reflow Temperature Conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs210f.doc VI TELEFILTER Filter specification version 2.0 28.07.2000 TFS 210 F 5/5 History Version Reason of Changes Name Date 1.0 - development specification Steiner 06.99.2000 2.0 - complete specification Steiner (tape&reel,terminating impedances matching, soldering profile, new date code added) 07.07.2000 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.