VECTRON TFS210F

tfs210f.doc
VI TELEFILTER
Filter specification
version 2.0
28.07.2000
TFS 210 F
1/5
Measurement Condition
Ambient Temperature:
Input Power Level:
Source impedance:
Load impedance:
Terminating impedances:
input:
output:
23 °C
0 dBm
50 Ω single ended
50 Ω single ended
480 Ω || -9,8pF
1030 Ω || -5,95pF
Characteristics
Remark:
Reference level for the relative attenuation arel is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin
is defined as the insertion loss ae. The nominal frequency fN is fixed to 210,38 MHz. The given values for the relative attenuation arel and for the
phase ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of
frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
Data
typ. Value
Limit
Insertion Loss
(Reference level)
ae = amin
8
Nominal Frequency
fN
-
5 dB - Bandwidth
BW
1,6 MHz
min.
1,26 MHz
Relative Attenuation
arel
-
max.
5
fN ± 0,63 MHz
fN ± 1,25 MHz ... fN ± 20 MHz
dB
max.
45
45
40
dB
210,38 MHz
-
fN - 1,25 MHz
fN + 1,25 MHz
fN ± 2,05 MHz
10
min.
dB
dB
dB
min.
min.
min.
35
35
37
dB
35 dB
dB
dB
dB
Pass Band Ripple
fN ± 0,300 MHz
-
0,3 dB
max.
1,2 dB
Phase linearity
fN ± 0,300 MHz
fN ± 0,630 MHz
-
ϕ
0,5 °rms
2,9 °rms
max.
max.
1,5 °rms
3,75 °rms
Operating Temperature Range
- 30 °C ... + 80 °C
Generated:
Checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs210f.doc
VI TELEFILTER
Filter specification
version 2.0
28.07.2000
TFS 210 F
2/5
Construction and pin connection
8
9
10
6
Datecode
5
S 210 F
M30
1
1
4
3
3
10
4
9
5
8
6
1
2
3
4
5
6
7
8
9
10
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Input
Input RF Return
Datecode:
K
L
M
...
Year+week
1998
1999
2000
50 Ω single ended test circuit
L2
L1
9
Input
50 Ohm
4
Output
SAW
C1
50 Ohm
C2
1,2,3,5,6,7,8
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs210f.doc
VI TELEFILTER
Filter specification
version 2.0
28.07.2000
TFS 210 F
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing:
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
Do
:
:
:
16
4
1,5
E
F
:
:
1,75 ± 0,1
7,5 ± 0,1
G (min) :
P2
:
P1
:
0,6
2 ± 0,1
8 ± 0,1
3000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
± 0,3
± 0,1
+ 0,5
Do
Po
P2
E
Ao
F
D1
W
Bo
Ct
G
D1(min) :
Ao
:
1,5
5,5
± 0,1
Bo
:
7,5
± 0,1
Ct
:
13,5+/-0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
50
C
C
:
13
+ 0,5
- 0,2
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the
sprocket holes.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs210f.doc
VI TELEFILTER
Filter specification
version 2.0
28.07.2000
TFS 210 F
4/5
Air Reflow Temperature Conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs210f.doc
VI TELEFILTER
Filter specification
version 2.0
28.07.2000
TFS 210 F
5/5
History
Version
Reason of Changes
Name
Date
1.0
- development specification
Steiner
06.99.2000
2.0
- complete specification
Steiner
(tape&reel,terminating impedances matching, soldering profile, new date code added)
07.07.2000
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.