VECTRON TFS420B

file: TFS420b.doc
version 1.1
01/99
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 420 B
1/4
______________________________________________________________________________________________________
Measurement condition
Ambient temperature:
23 °C
Input power level:
0 dBm
Source impedance:
162 Ω || -0,39 pF
Load impedance:
162 Ω || -0,39 pF
Construction, pin connection and 50 Ω test circuit
See page 2
Stability characteristics and packing
See page 3
Air reflow temperature conditions
See page 4
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 420 B is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the
2 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 420 MHz without tolerance. The given values for
the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted
due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo
Data
typ. value
tolerance / limit
______________________________________________________________________________________________________
3
dB
max. 5
dB
ae = amin
Insertion loss
(Reference level)
______________________________________________________________________________________________________
420
MHz
fN
Nominal frequency
_____________________________________________________________________________________________________
420
MHz
Centre frequency
fo
______________________________________________________________________________________________________
Pass band ripple
fN ± 10 MHz
1
dB
max. 2
dB
______________________________________________________________________________________________________
Relative attenuation
arel
320 MHz ... 340 MHz
60
dB
min. 50
dB
365 MHz ... 385 MHz
> 40
dB
min. 40
dB
______________________________________________________________________________________________________
Operating temperature range
- 25 °C ... + 75 °C
______________________________________________________________________________________________________
- 65
ppm/K
Temperature coefficient of frequency TCf
______________________________________________________________________________________________________
Input power level
max. 10
dBm
______________________________________________________________________________________________________
*) At the moment we are carrying out tests to check the possibility of guaranteing higher limiting values.
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: TFS420b.doc
version 1.1
01/99
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 420 B
2/4
______________________________________________________________________________________________________
Construction and pin connection
S 420B
L1
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Output RF Return
Output
Package Ground
Ground
Ground
Ground
Input RF Return
Input
Package Ground
Ground
50 Ω test circut 1
L1
IN
10
SAW
C1
L2
4
OUT
C2
1,2,3,5,6,7,8,9,11,12
50 Ω test circut 2
C1
10
IN
L1
C2
4
SAW
L2
OUT
1,2,3,5,6,7,8,9,11,12
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: TFS420b.doc
version 1.1
01/99
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 420 B
3/4
______________________________________________________________________________________________________
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
30g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 150 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes;
DIN IEC 68 T2 - 6
3. Damp heat:
90 % to 95 % rel. humidity, 40 °C, 10 days;
IEC Pub. 68 - 2 - 3
4. Resistance to
solder heat (Reflow):
260 °C for 10 sec;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel: 3000
Tape (all dimensions in mm)
W
Po
Do
:
:
:
16
4
1,5
D1
E
:
:
1,5 + 0,5
1,75 ± 0,1
F
:
G (min) :
7,5 ± 0,1
0,75
P2
P1
:
:
2
8
D1(min) :
Ao
:
Bo
:
1,5
5,4
7,4
EMBOSSED CARRIER TAPE
± 0,3
± 0,1
+ 0,5
Do
Po
P2
E
Ao
F
D1
13,4
± 0,1
W
Bo
± 0,05
± 0,1
G
P1
± 0,1
± 0,1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
>= 90
C
C
:
13
± 0,25
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: TFS420b.doc
version 1.1
01/99
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 420 B
4/4
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.