file: TFS420b.doc version 1.1 01/99 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 420 B 1/4 ______________________________________________________________________________________________________ Measurement condition Ambient temperature: 23 °C Input power level: 0 dBm Source impedance: 162 Ω || -0,39 pF Load impedance: 162 Ω || -0,39 pF Construction, pin connection and 50 Ω test circuit See page 2 Stability characteristics and packing See page 3 Air reflow temperature conditions See page 4 Characteristics Remark: Reference level for the relative attenuation arel of the TFS 420 B is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 2 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 420 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo Data typ. value tolerance / limit ______________________________________________________________________________________________________ 3 dB max. 5 dB ae = amin Insertion loss (Reference level) ______________________________________________________________________________________________________ 420 MHz fN Nominal frequency _____________________________________________________________________________________________________ 420 MHz Centre frequency fo ______________________________________________________________________________________________________ Pass band ripple fN ± 10 MHz 1 dB max. 2 dB ______________________________________________________________________________________________________ Relative attenuation arel 320 MHz ... 340 MHz 60 dB min. 50 dB 365 MHz ... 385 MHz > 40 dB min. 40 dB ______________________________________________________________________________________________________ Operating temperature range - 25 °C ... + 75 °C ______________________________________________________________________________________________________ - 65 ppm/K Temperature coefficient of frequency TCf ______________________________________________________________________________________________________ Input power level max. 10 dBm ______________________________________________________________________________________________________ *) At the moment we are carrying out tests to check the possibility of guaranteing higher limiting values. Generated: Checked / approved: ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: TFS420b.doc version 1.1 01/99 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 420 B 2/4 ______________________________________________________________________________________________________ Construction and pin connection S 420B L1 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Output RF Return Output Package Ground Ground Ground Ground Input RF Return Input Package Ground Ground 50 Ω test circut 1 L1 IN 10 SAW C1 L2 4 OUT C2 1,2,3,5,6,7,8,9,11,12 50 Ω test circut 2 C1 10 IN L1 C2 4 SAW L2 OUT 1,2,3,5,6,7,8,9,11,12 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: TFS420b.doc version 1.1 01/99 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 420 B 3/4 ______________________________________________________________________________________________________ Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 30g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 150 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes; DIN IEC 68 T2 - 6 3. Damp heat: 90 % to 95 % rel. humidity, 40 °C, 10 days; IEC Pub. 68 - 2 - 3 4. Resistance to solder heat (Reflow): 260 °C for 10 sec; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 3000 Tape (all dimensions in mm) W Po Do : : : 16 4 1,5 D1 E : : 1,5 + 0,5 1,75 ± 0,1 F : G (min) : 7,5 ± 0,1 0,75 P2 P1 : : 2 8 D1(min) : Ao : Bo : 1,5 5,4 7,4 EMBOSSED CARRIER TAPE ± 0,3 ± 0,1 + 0,5 Do Po P2 E Ao F D1 13,4 ± 0,1 W Bo ± 0,05 ± 0,1 G P1 ± 0,1 ± 0,1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 16,4 +2 22,4 >= 90 C C : 13 ± 0,25 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: TFS420b.doc version 1.1 01/99 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 420 B 4/4 ______________________________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.