VECTRON TFS471C

tfs471C.doc
version 1.2
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter Specification
TFS 471 C 1/4
______________________________________________________________________________________________________
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
23 °C
0 dBm
TBD
Construction and pin connection
see page 2
50 Ω test circuit
see page 2
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 471 C is the maximum of the attenuation amax. The maximum of the attenuation within
the usable signal bandwidth is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower
frequencies at the 3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 471,55 MHz without tolerance.
The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre
frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for
the centre frequency fo
D a t a
typ. value
Variation/ Limitation
______________________________________________________________________________________________________
3,5 dB
max.
5 dB
ae = amax
Insertion loss
(Reference level)
______________________________________________________________________________________________________
fN
Nominal frequency
471,55 MHz
______________________________________________________________________________________________________
f0
Centre frequency
471,55 MHz
______________________________________________________________________________________________________
150
kHz
BW
3 dB - bandwidth
______________________________________________________________________________________________________
Usable signal bandwidth
min. fN ± 25 kHz
______________________________________________________________________________________________________
Relative attenuation
arel
fN + 910 kHz
min. 52
dB
______________________________________________________________________________________________________
-0,036 ppm/K2
TCf
Temperature coefficient of frequency
______________________________________________________________________________________________________
Frequency inversion temperature
+ 25 °C
______________________________________________________________________________________________________
Operating temperature range
- 30°C ... + 70°C
______________________________________________________________________________________________________
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs471C.doc
version 1.2
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter Specification
TFS 471 C 2/4
______________________________________________________________________________________________________
Construction and pin connection
(All dimensions in mm)
8
9
10
7
6
TFS 471 C
tft
L1
1
2
5
1
2
3
4
5
6
7
8
9
10
4
3
Ground
Ground
Ground
Ground
Output
Ground
Ground
Ground
Ground
Input
50 Ω test circuit 1
L2
L1
10
5
C1
C2
1,2,3,4
6,7,8,9
50 Ω test circuit 2
C1
C2
10
5
L1
L2
1,2,3,4
6,7,8,9
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs471C.doc
version 1.2
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter Specification
TFS 471 C 3/4
______________________________________________________________________________________________________
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
100g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,075 mm or 1g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(steady state)
90 % to 95 % rel. humidity, 40 °C, 10 days;
DIN IEC 68 - 2 - 3
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on sheet 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel: 3000
Tape (all dimensions in mm)
W
:
Po
:
Do
:
D1
:
E
:
F
:
G (min) :
P2
:
P1
:
D1(min) :
Ao
:
Bo
:
16
± 0,3
4
± 0,1
1,5 + 0,5
1,5 + 0,5
1,75 ± 0,1
7,5 ± 0,1
0,75
2 ± 0,05
8 ± 0,1
1,5
5,3 ± 0,1
9,7 ± 0,1
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
F
D1
13,4
± 0,1
W
Bo
G
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
>= 90
C
C
:
13
± 0,25
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs471C.doc
version 1.2
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter Specification
TFS 471 C 4/4
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.