VECTRON TFS244B

tfs244b.eng
version 1.1
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS244 B
1/4
______________________________________________________________________________________________________
Measurement condition
Ambient temperature:
Input power level:
terminating impedances:
23 C
0 dBm
t.b.d, near 500 Ohm
Construction and pin connection
see page 2
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 244 B is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 3
dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 244 MHz without tolerance. The given values for the
relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted
due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
Data
typ. value
limit
______________________________________________________________________________________________________
3.5
dB
max 5
dB
ae = amin
Insertion loss
(Reference level)
______________________________________________________________________________________________________
244
MHz
fN
Norminal frequency
______________________________________________________________________________________________________
1,0 dB
In band ripple
in fo ± 80 kHz
______________________________________________________________________________________________________
Relative attenuation
244,0 MHz ± 80
arel
kHz
max 3
dB
244,0 MHz ± 400
kHz ... 244,0 MHz ± 600
kHz
min 25
dB
244,0 MHz ± 600
kHz ... 244,0 MHz ± 800
kHz
min 40
dB
244,0 MHz ± 800
kHz ... 244,0 MHz ± 1,6 MHz
min 45
dB
244,0 MHz ± 1,6 MHz ... 244,0 MHz ± 10
MHz
min 50
dB
______________________________________________________________________________________________________
GDD
Group delay distortion
244,0 MHz ± 80
kHz
1
µs
max 1,5
µs
______________________________________________________________________________________________________
Operating temperature range
- 20 C ... + 85 C
______________________________________________________________________________________________________
ca. - 0,036 ppm/K²
Temperature coefficient of frequency TC
______________________________________________________________________________________________________
Frequency inversion temperature
+ 20 ... + 30 C
______________________________________________________________________________________________________
generated:
checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs244b.eng
version 1.1
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS244 B
2/4
______________________________________________________________________________________________________
Construction, pin connection and 50 Ω matching network
8
9
7
6
5
TFS 244 B
tft
G1
10
1
2
4
3
Pinning - unballanced
1 Ground
6 Ground
2 Ground
7 Ground
3 Ground
8 Ground
4 Ground
9 ext. Coil
5 Output
10 Input
50 Ω test circuit (unballanced)
C1
10
C2
5
SAW
9
L1
L2
L3
1,2,3,4,6,7,8
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs244b.eng
version 1.1
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS244 B
3/4
______________________________________________________________________________________________________
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
100g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,075 mm or 1g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(steady state)
90 % to 95 % rel. humidity, 40 °C, 10 days;
DIN IEC 68 - 2 - 3
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on sheet 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel: 3400
Tape (all dimensions in mm)
W
:
Po
:
Do
:
D1
:
E
:
F
:
G (min) :
P2
:
P1
:
D1(min) :
Ao
:
Bo
:
16
± 0,3
4
± 0,1
1,5 + 0,5
1,5 + 0,5
1,75 ± 0,1
7,5 ± 0,1
0,75
2 ± 0,05
8 ± 0,1
1,5
5,3 ± 0,1
9,7 ± 0,1
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
F
D1
13,4
± 0,1
W
Bo
G
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
>= 90
C
C
:
13
± 0,25
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs244b.eng
version 1.1
06.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS244 B
4/4
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.