VECTRON TFS71H

File name: Tfs71H.doc
version 1.1
VI TELEFILTER
1.
Filter specification
11.01.2002
TFS 71H
1/5
Measurement condition :
Ambient temperature TA:
Input power level:
Terminating impedances in fc *) :
25
°C
0
dBm
for input:
for output:
440 Ω  - 29,12 pF.
450 Ω  - 33,11 pF.
2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 71H is the minimum of the pass band attenuation amin. The minimum of
the pass band attenuation amin is defined as the insertion loss ae. The centre frequence fc is the arithmetic mean value of the upper and lower
frequencies at the 3,75 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 71,100 MHz without
tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also
if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production
tolerance for the centre frequency fc. All specified values are guarantied in operating temperature range.
Data
Insertion loss (Reference level)
Nominal frequency
Centre frequency
typ. value
16
dB
ae
fN
fc at ambient temperature (fCTA)
Pass band
Amplitude ripple (p-p) in
71,100
PB
fN .... fN ± 500 kHz
fN - 525 kHz ... fN + 525 kHz
0,5
dB
dB
dB
dB
Relative attenuation
arel
fN
...... fN ± 525 kHz
fN ± 525 kHz .... fN ± 590 kHz
fN ± 750
fN ± 900
dB
1120
1150
1205
1215
kHz
kHz
kHz
MHz
min.
1050
min.
1180
kHz
1445
1520
1540
1555
MHz
kHz
kHz
kHz
max. 1500
kHz
max. 1800
kHz
-
kHz .... fN ± 900 kHz
kHz .... fN ± 40 MHz
Group delay ( mean value in PB ):
Group delay ripple in PB (p-p):
Deviation from linear phase (p-p) in
Deviation from linear phase ( r.m.s.) in
fN .... fN ± 630 kHz
fN .... fN ± 630 kHz
Input/Output return loss with matching network (S11/S22):
Frequency inversion temperature ( To ) :
Temperature coefficient of frequency ( Tcf ) :
Frequency deviation of fc over temperature: ** )
MHz
71,110 MHz
Bandwidth :
1
dB
1,5
dB
3,0
dB
3,75
dB
25
40
45
50
tolerance / limit
max. 17
dB
max.
max.
kHz
1
dB
3,75 dB
32
55
dB
dB
min.
min.
25
45
dB
dB
7,1
550
6°
1,6°
µs
ns
6,0 .... 7,75
max.
1
µs
µs
max.
2
degree
9...12
dB
min.
8
dB
20...30 °C
- 0,036
ppm/K²
∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz)
Operating temperature range ( OTR ) :
Storage temperature range :
0 °C ... + 85 °C
- 30 °C ... + 85 °C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) fTo is reference frequence fc at frequency inversion temperature (To )
Generated:
Wadim Dunzow
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Phone: (603) 598-0070 Fax: (603) 598-0075
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs71H.doc
version 1.1
VI TELEFILTER
Filter specification
TFS 71H
11.01.2002
2/5
3. Package, pin grid 2,54 mm
TFS
71H
P22
Date code
Datecode:
M
N
P
Year+week
2000
2001
2002
...
...
Pin 1 - Input.
Pin 9 - Input RF Return.
Pin 5 - Output.
Pin 6 - Output RF Return.
Pin 2 - 4, 7, 8 PackageGround.
4. 50 Ω matching network ( see Application Note ):
Scheme 1.
1
L11 + L12
2
3
4
5
L21 + L22
50 Ω
50 Ω
L3 ║ R1
9
8
7
6
R2 ║ L4
Scheme 2.
C1
1
L1
2
3
4
L2
5
C2
50 Ω
R1
9
8
7
6
R2
For final test we use scheme 1.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Phone: (603) 598-0070 Fax: (603) 598-0075
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs71H.doc
version 1.1
VI TELEFILTER
Filter specification
TFS 71H
11.01.2002
3/5
5. Stability Characteristics :
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Phone: (603) 598-0070 Fax: (603) 598-0075
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs71H.doc
version 1.1
VI TELEFILTER
Filter specification
11.01.2002
TFS 71H
4/5
6. Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Phone: (603) 598-0070 Fax: (603) 598-0075
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: Tfs71H.doc
VI TELEFILTER
version 1.1
Filter specification
TFS 71H
11.01.2002
5/5
7. History :
Version
Reason of Changes
Name
Date
1.0
Generate development specification according to customer requirements.
Pfeiffer W.
18.07.2001
1.1
Generate filter specification.
Dunzow W.
11.01.2002
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Phone: (603) 598-0070 Fax: (603) 598-0075
e-mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of
their use or application. No rights under any patent accompany the sale of any such product(s) or information.