tfs225A.doc version 2.1 VI TELE FILTER 29.09.2000 Filter Specification TFS 225A 1/4 Measurement Condition Ambient temperature: Input power level: Terminating impedances 23 °C 0 dBm for input: 440 Ω || -2.6 pF for output: 440 Ω || -2.6 pF 170 nH Coupling coil: Characteristics Remark: Reference level for the relative attenuation arel of the TFS 225 A is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. Value Insertion Loss (Reference Level) ae = amin Center Frequency fc Relative Attenuation arel 225,0 MHz 225,0 MHz 225,0 MHz 225,0 MHz 225,0 MHz 225,0 MHz ± ± ± ± ± ± 80 200 400 600 1,6 3,0 Group Delay GD Group Delay Ripple Group Delay Ripple 3,0 225,0 kHz kHz ... 225,0 MHz kHz ... 225,0 MHz kHz ... 225,0 MHz kHz ... 225,0 MHz MHz ...225,0 MHz ± 400 ± 600 ± 1,6 ± 3,0 ± 25,0 (p-p) 225,0 MHz ± 50 kHz 225,0 MHz ± 85 kHz kHz kHz kHz MHz MHz dB MHz 1 1 Limit max 5,5 - max 2 min 8 min 28 min 38 min 48 min 50 µs µs dB max 1,2 max 2,0 dB dB dB dB dB dB µs µs Operating Temperature Range - 25 °C ... + 80 °C Storage Temperature Range - 30 °C ... + 85 °C Temperature Coefficient of Frequency Frequency Inversion Temperature TCf ca. - 0,036 25 ppm/K² °C Generated: Checked / Approved: VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs225A.doc version 2.1 VI TELE FILTER 29.09.2000 Filter Specification TFS 225A 2/4 Construction, pin configuration and 50 Ω - matching network (All dimensions in mm) Datecode: K L M ... S 225 A M36 1 2 3 4 5 6 7 8 9 10 11 12 Year+week 1998 1999 2000 Input Input Ground Coupling coil Package Ground Ground Output Output Ground Ground Package Ground Ground 50 Ohm Test circuit LB-IN L1 8 SAW C1 L3 L2 1 LB-OUT C2 2 7 L4 4 3,5,6,9,10,11,12 L5 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs225A.doc version 2.1 VI TELE FILTER 29.09.2000 Filter Specification TFS 225A 3/4 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer Tape (all dimensions in mm) W Po Do E F : : : : : 0,6 2 8 1,5 5,5 7,5 Ct 13,5 ± 0,1 : EMBOSSED CARRIER TAPE 16 ± 0,3 4 ± 0,1 1,5 + 0,1 1,75 ± 0,1 7,5 ± 0,1 G (min) : P2 : P1 : D1(min) : Ao : Bo : 3000 min 300 mm min 500 mm min 300 mm Do Po P2 E Ao F D1 Ct W Bo ± 0,1 ± 0,1 G ± 0,1 ± 0,1 P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 16,4 +2 22,4 50 C C : A 13,0 +0,5/-0,2 N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs225A.doc version 2.1 VI TELE FILTER 29.09.2000 Filter Specification TFS 225A 4/4 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.