tfs140e.doc version 1.3 06.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 140E - 1/4 ______________________________________________________________________________________________________ Measurement Condition Ambient Temperature: 23 Input Power Level: 0 Terminating Impedances: for Input: for Output: °C dBm 860 Ω - 1,2 pF 860 Ω - 1,2 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 140 E is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 140,455 MHz without tolerance. The given values for the relative attenuation arel have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo. Data typ. Value Variation/ Limitation ______________________________________________________________________________________________________ Insertion Loss ae max 5 dB (Reference Level) ______________________________________________________________________________________________________ Nominal Frequency 140,455 MHz fN ______________________________________________________________________________________________________ Relative Attenuation arel fN ± 25 kHz max 3 dB kHz ... fN ± 125 kHz min 8 dB fN ± 75 kHz ... fN ± 455 kHz min 20 dB fN ± 125 min 60 dB @ fN ± 455 kHz ______________________________________________________________________________________________________ Intermodulation (third order IM products) Intermodulation in the composit signal by max. -88 dBm fN ± 60 kHz and fN ± 120 kHz each of – 20 dBm ______________________________________________________________________________________________________ Operating Temperature Range - 40 °C ... + 85 °C Storage Temperature Range - 54 °C ... + 100 ° ______________________________________________________________________________________________________ Temperature Coefficient - 0,036 ppm/K2 TC ______________________________________________________________________________________________________ Frequency Inversion Temperature + 25 °C ______________________________________________________________________________________________________ Generated: Checked / Approved: ______________________________________________________________________________________________________ VI TELEFILTER Vectron Technologies, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs140e.doc version 1.3 06.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 140E - 2/4 ______________________________________________________________________________________________________ Construction and Pin Configuration (All Dimensions in mm) Remark: Only in the development stage the name of the filter is TFD 140 E. TFS 140 E tft L5 - Pin 4 - Output Pin 5 - Output RF Return Pin 9 - Input Pin 10 - Input RF Return Pin 1,2,3,6,7,8 - Ground R0.15 L1 9 4 10 5 C1 L2 C2 1,2,3,6,7,8 ______________________________________________________________________________________________________ VI TELEFILTER Vectron Technologies, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs140e.doc version 1.3 06.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 140E - 3/4 ______________________________________________________________________________________________________ Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 30g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,075 mm or 1g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (steady state) 90 % to 95 % rel. humidity, 40 °C, 10 days; DIN IEC 68 - 2 - 3 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on sheet 4; Packing Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 1700 Tape (all dimensions in mm) W Po Do D1 E F : : : : : : G (min) : P2 : P1 : D1(min) : Ao : Bo : 24 ± 0,3 4 ± 0,1 1,5 + 0,5 1,5 + 0,5 1,75 ± 0,1 11,5 ± 0,1 EMBOSSED CARRIER TAPE Do Po P2 E Ao ± 0,1 W Bo 0,75 2 ± 0,1 12 ± 0,1 1,5 7,1 ± 0,2 13,9 F D1 21,4 G P1 COVER TAPE ± 0,2 W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 24,4 +2 30,4 >= 90 C C : 13 ± 0,25 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. ______________________________________________________________________________________________________ VI TELEFILTER Vectron Technologies, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs140e.doc version 1.3 06.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 140E - 4/4 ______________________________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER Vectron Technologies, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.