VECTRON TFS210E

tfs210e.doc
version 1.4
6/99
______________________________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 210 E
1/4
______________________________________________________________________________________________________
Measurement Condition
Ambient Temperature:
Input Power Level:
Source impedance:
Load impedance:
Terminating impedances:
input:
output:
23 °C
0 dBm
50 Ω single ended
50 Ω single ended
630 Ω || -9.2 pF
915 Ω || -5.7pF
Construction, pin connection and 50 Ω test circuit
see page 2
Stability characteristics and packing
see page 3
Air reflow temperature conditions
see page 4
Characteristics
Remark:
Reference level for the relative attenuation arel is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin
is defined as the insertion loss ae. The nominal frequency fN is fixed to 210,38 MHz. The given values for the relative attenuation arel and for the
phase ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of
frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
Data
typ. Value
Limit
______________________________________________________________________________________________________
Insertion Loss
8
dB
max. 10
dB
ae = amin
(Reference level)
______________________________________________________________________________________________________
Nominal Frequency
fN
210,38 MHz
______________________________________________________________________________________________________
5 dB - Bandwidth
1,6 MHz
min.
1,26 MHz
BW
______________________________________________________________________________________________________
Relative Attenuation
arel
fN ± 0,63 MHz
-
fN ± 1,25 MHz ... fN ± 20 MHz
fN - 1,25 MHz
fN + 1,25 MHz
fN ± 2,05 MHz
max.
-
45
45
40
dB
dB
dB
5
min.
min.
min.
min.
35
35
37
dB
35 dB
dB
dB
dB
______________________________________________________________________________________________________
Pass Band Ripple
fN ± 0,300 MHz
0,3 dB
max.
1,2 dB
______________________________________________________________________________________________________
Phase linearity
ϕ
fN ± 0,300 MHz
0,5 °rms
max.
1,5 °rms
fN ± 0,630 MHz
2,9 °rms
max.
3,75 °rms
_____________________________________________________________________________________________________
Operating Temperature Range
- 30 °C ... + 80 °C
______________________________________________________________________________________________________
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs210e.doc
version 1.4
6/99
______________________________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 210 E
2/4
______________________________________________________________________________________________________
Construction and pin connection
S 210 E
KN
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Ground
Input RF Return
Input
Ground
Ground
50 Ω single ended test circuit
L2
L1
10
Input
50 Ohm
4
Input
SAW
C1
50 Ohm
C2
1,2,3,5,6,7,
8,9,11,12
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs210e.doc
version 1.4
6/99
______________________________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 210 E
3/4
______________________________________________________________________________________________________
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
30g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 150 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes;
DIN IEC 68 T2 - 6
3. Damp heat:
(steady state)
90 % to 95 % rel. humidity, 40 °C, 10 days;
DIN IEC 68 - 2 - 3
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on sheet 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel: 3400
Tape (all dimensions in mm)
W
:
16
± 0,3
Po
:
4
± 0,1
Do
:
1,5
+ 0,5
D1
E
F
:
:
:
1,5 + 0,5
1,75 ± 0,1
7,5 ± 0,1
G (min) :
P2
:
Do
Po
P2
E
Ao
8
1,5
± 0,1
Ao
Bo
5,4
7,4
± 0,1
± 0,1
F
D1
13,4
± 0,1
W
Bo
0,75
2 ± 0,05
P1
:
D1(min) :
:
:
EMBOSSED CARRIER TAPE
G
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
>= 90
C
C
:
13
± 0,25
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs210e.doc
version 1.4
6/99
______________________________________________________________________________________________________
VI TELEFILTER
Filter specification
TFS 210 E
4/4
______________________________________________________________________________________________________
Air Reflow Temperature Conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.