Filter Specification
TFS 236
1/5
Measurement condition
23 °C
0 dBm
360 Ohm || -2.2 pF,
360 Ohm || -2.2 pF,
89 nH
Ambient temperature:
Input power level:
Source impedance
Load impedance:
Ext. Coil:
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 236 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3
dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 236,6 MHz without tolerance. The given values for
the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted
due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
(Reference level)
ae = amin
2,5
Nominal frequency
fN
-
Pass band ripple
fN - 85 kHz ... fN + 93 kHz
-
Relative attenuation
arel
236,0 MHz ± 120
kHz
1,5
236,0 MHz
236,0 MHz
236,0 MHz
236,0 MHz
236,0 MHz
236,0 MHz
236,0 MHz
±
±
±
±
±
±
±
330
400
600
800
1,6
3,0
20
kHz ... 236,6 MHz
kHz ... 236,6 MHz
kHz ... 236,6 MHz
kHz ... 236,6 MHz
MHz ... 236,6 MHz
MHz ... 236,6 MHz
MHz ...236,6 MHz
±
±
±
±
±
±
±
400
600
800
1,6
3,0
20
100
Group delay distortion
GDD
236,0 MHz ± 50
kHz
236,0 MHz ± 70
kHz
236,0 MHz ± 100
kHz
kHz
kHz
MHz
MHz
MHz
MHz
MHz
22
33
50
55
55
55
55
0,5
0,8
1,2
dB
dB
max 1,5
dB
dB
max
3
dB
dB
dB
dB
dB
dB
dB
dB
min
min
min
min
min
min
min
18
25
40
45
45
46
45
dB
dB
dB
dB
dB
dB
dB
µs
µs
µs
max 1,2
max 1,5
max 2,5
µs
µs
µs
- 20 °C ... + 70 °C
- 30 °C ... + 85 °C
Storage temperature range
Frequency inversion temperature
max 5
236,000 MHz
Operating temperature range
Temperature coefficient of frequency
tolerance / limit
TCf
- 0,036 ppm/K²
+ 25
-
°C
Generated:
Checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Version 1.1
tfs236.doc
VI TELEFILTER
11.10.2000
Filter Specification
TFS 236
2/5
Construction and pin configuration
(All dimensions in mm)
Date code:
K
L
M
...
S 236
M41
1
2
3
4
5
6
7
8
9
10
11
12
Year + week
1998
1999
2000
Balanced Output
Balanced Output
Ground
Coupling Coil
Ground
Ground
Balanced Input
Balanced Input
Ground
Ground
Ground
Ground
50 Ohm Test circuit 1
LB-IN
L1
8
SAW
C1
LB-OUT
C2
2
7
L3
L2
1
L4
4
3,5,6,9,10,11,12
L5
50 Ohm Test circuit 2
LB-IN
C2
C1
8
SAW
L1
L2
2
7
C3
LB-OUT
1
C4
4
3,5,6,9,10,11,12
L3
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Version 1.1
tfs236.doc
VI TELEFILTER
11.10.2000
Filter Specification
TFS 236
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
Do
E
F
:
:
:
:
:
G (min) :
P2
:
P1
:
D1(min) :
Ao
:
Bo
:
CT
:
EMBOSSED CARRIER TAPE
16
± 0,3
4
± 0,1
1,5 + 0,1
1,75 ± 0,1
7,5 ± 0,1
0,6
2
8
1,5
5,5
7,5
2000
min 300 mm
min 500 mm
min 300 mm
Do
Po
P2
E
Ao
F
D1
CT
W
Bo
± 0,1
± 0,1
G
± 0,1
± 0,1
P1
COVER TAPE
13,5 + 0,1
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
50
C
C
:
13
A
+0,5 / -0,2
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Version 1.1
tfs236.doc
VI TELEFILTER
11.10.2000
Filter Specification
TFS 236
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Version 1.1
tfs236.doc
VI TELEFILTER
Filter Specification
11.10.2000
TFS 236
5/5
History
Version
Reason of Changes
Name
Date
1.1
- Change centre frequency from 236,6 MHz to 236,0 MHz.
- Change date code from month to week.
- Correct tape and reel information
Dr. Wall
11.10.2000
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.