tfs190d.doc version 1.4 VI TELEFILTER 07.09.2001 Filter specification TFS 190 D 1/5 Measurement Condition Ambient Temperature: Input Power Level: Terminating impedances * 23 0 Input: output: °C dBm T.B.D. T.B.D. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 190 D is the insertion loss. The insertion loss ae is defined as the minimum of attenuation in pass band. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 190,000 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. Value Limit Insertion Loss (Reference level) ae = amin 8 Nominal Frequency fN - 5 dB - Bandwidth BW 1,6 MHz min. 1,26 MHz Pass Band Ripple fN ± 0,300 MHz - 0,3 dB max. 1,2 dB Relative Attenuation arel - max. 5 min. min. min. min. 35 35 37 fN ± 0,63 MHz fN ± 1,25 MHz ... fN ± 20 MHz fN - 1,25 MHz fN + 1,25 MHz fN ± 2,05 MHz 45 45 40 Group delay ripple fN ± 0,630 MHz Operating Temperature Range Temperature coefficient of frequency dB max. 190 dB dB dB TCf** Frequency inversion temperature T0 10 dB MHz dB 35 dB dB dB dB max. 1 µs - 40 °C ... + 65 °C -0,036 ppm/K² - + 25 °C - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz) Generated: Checked / approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs190d.doc version 1.4 VI TELEFILTER 07.09.2001 Filter specification TFS 190 D 2/5 Construction and pin connection Pinning 1 2 3 4 5 6 7 8 9 10 S190D N36 Datecode 1 2 3 10 4 9 5 8 7 Ground Input RF return Input Ground Ground Ground Output RF return Output Ground Ground Datecode Year+month L M N ... 1999 2000 2001 6 50 Ω test circuit (unbalanced) L1 L2 3 Input 8 Output SAW 50 Ohm C1 50 Ohm C2 1,2,4,5,6,7,9,10 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs190d.doc version 1.4 VI TELEFILTER 07.09.2001 Filter specification TFS 190 D 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 1,5 mm or 20g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on sheet 4; Packing Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer Tape (all dimensions in mm) W Po Do : : : 16 ± 0,3 4 ± 0,1 1,5 + 0,1 D1 E : : 1,5 + 0,1 1,75 ± 0,1 F : G (min) : 7,5 ± 0,1 0,6 P2 : P1 : D1(min) : 2 12 1,5 ± 0,1 ± 0,1 Ao Bo 7,6 9,6 ± 0,1 ± 0,1 : : 2000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Po Do P2 E Ao F D1 13,4 ± 0,1 W Bo G P1 COVER TAPE W2 Reel (all dimensions in mm): A : W1 : W2 (max) : N (min) C : 330 16,4 +2 22,4 A : 12,8 C N >= 60 ± 0,1 W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs190d.doc version 1.4 VI TELEFILTER 07.09.2001 Filter specification TFS 190 D 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs190d.doc version 1.4 VI TELEFILTER Filter specification 07.09.2001 TFS 190 D 5/5 History Version Reason of Changes Name Date 1.0 generate specification according to customer requirements Jaffer 31.07.2001 1.1 Add “frequency inversion temperature” Add “storage temperature” Add “temperature coefficient of frequency” Correct “packing” information Herrler 01.08.2001 1.2 temperature range adjusted according to customer demands Steiner 06.08.2001 1.3 Change Input and Output pins Herrler 16.08.2001 1.4 remove of source/load impedance . remove of phase linearity correct of tape and reel dimentions filter specification Dr. Sabah 07.09.2001 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.