VECTRON TFS211C

Version 2.0
tfs211c.doc
VI TELEFILTER
25.01.2001
Filter specification
TFS 211 C
1/5
Measurement condition
Ambient temperature:
Input power level:
terminating impedances
balanced input:
balanced output:
20 ... 25
5±2
°C
dBm
1,1 kΩ || -5.1pF
1,1 kΩ || -5.2pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS211C is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1
dB filter attenuation level relative to the insertion loss ae. The given values for the relative attenuation arel and for the group delay ripple have to be
reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating
temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
ae = amin
6 ... 7 dB
Nominal frequency
fN
-
Centre frequency
fc
211
arel
Relative attenuation
fN - 200
kHz ... fN + 200
fN
fN
fN
fN
1
± 600
±
1,2
+
1,8
+
7,0
1,0
2,0
3,0
MHz
kHz
MHz
MHz
MHz
GHz
GHz
GHz
... fN ... fN ±
... fN ±
... fN +
...
...
...
...
1,8
1,2
1,8
7,0
1,0
2,0
3,0
4,0
kHz
min.
max.
35
30
-
4,5
8
211
dB
dB
MHz
MHz
0,5 dB
MHz
MHz
MHz
MHz
GHz
GHz
GHz
GHz
Group delay ripple GD
fN - 200 kHz ... fN + 200 kHz
limit
max.
1
dB
min.
min.
min.
min.
min.
min.
30
10
20
30
45
40
dB
dB
dB
dB
dB
dB
max. 350
ns
dB
dB
max.
Input power level
-
max. + 10
dBm
Permissible DC voltage
-
max.
V
10
- 35 °C ... + 85 °C
- 35 °C ... + 85 °C
Operating temperature range
Storage temperature range
Temperature coefficient
TC
- 0,036 ppm/K²
Frequency inversion temperature
To
25
2)
1)
°C
-
Note 1) - ∆f (Hz) = TC (ppm/K²) x (T - To)² x FTo (MHz)
Note 2) If the filter is used between -10°C and -35°C all given frequencies may be changed down to max. - 30 kHz
Generated:
Checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Version 2.0
tfs211c.doc
VI TELEFILTER
25.01.2001
Filter specification
TFS 211 C
2/5
Construction and pin connection
(All dimensions in mm)
8
9
7
5
TFS 211 C
tft
M04
10
1
1
2
3
4
5
6
7
8
9
10
6
2
4
3
Ground
Ground
Ground
Balanced output
Balanced output
Ground
Ground
Ground
Balanced input
Balanced input
50 Ω test circuit
1:1
Input
50 Ohm
L1
9
SAW
L3
L2
L4
4
10
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
1:1
Output
50 Ohm
L6
L5
5
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Version 2.0
tfs211c.doc
VI TELEFILTER
25.01.2001
Filter specification
TFS 211 C
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
Do
E
:
:
:
:
F
:
G (min) :
P2
:
P1
:
D1(min) :
Ao
:
EMBOSSED CARRIER TAPE
16
± 0,3
4
± 0,1
1,5 + 0,1
1,75 ± 0,1
Do
Po
P2
E
Ao
7,5 ± 0,1
0,60
2
± 0,1
± 0,1
8
1,5
5,30
3000
min 300 mm
min 500 mm
min 300 mm
F
D1
W
Bo
CT
G
± 0,2
Bo
:
9,70
± 0,2
CT
:
13,5
± 0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,40 +2,0
22,4
50
C
C
:
13,0
A
± 0,5/-0.2
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Version 2.0
tfs211c.doc
VI TELEFILTER
25.01.2001
Filter specification
TFS 211 C
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Version 2.0
tfs211c.doc
VI TELEFILTER
Filter specification
25.01.2001
TFS 211 C
5/5
History
Version
Reason of Changes
Name
Date
2.0
generate detailled specification
- add terminating impedances
- add matching circuit
- add tape and reel dimensions, stability characteristics and reflow profile
Steiner
24.01.2001
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.