VECTRON TFS246H

version1.1
tfs246h.eng
06.01.02
______________________________________________________________________________________________________
TELE FILTER tft GmbH
SAW filter specification
TFS 246 H
1/4
______________________________________________________________________________________________________
Measurement condition
23 °C
0 dBm
490 Ω || -2.62 pF (± 10%)
490 Ω || -2.62 pF (± 10%)
82 nH
Ambient temperature:
Input power level:
Source impedance:
Load impedance:
Ext coil:
Construction
see page 2
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 246 H is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 3
dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 246 H MHz without tolerance. The given values for
the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted
due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
Data
typ. value
tolerance / limit
______________________________________________________________________________________________________
2,5
dB
max 5
dB
ae = amin
Insertion loss
(Reference level)
______________________________________________________________________________________________________
246,000 MHz
fN
Nominal frequency
______________________________________________________________________________________________________
Pass band ripple
fN - 85 kHz ... fN + 93 kHz
max 1,5
dB
______________________________________________________________________________________________________
Relative attenuation
arel
246,0 MHz ± 120
kHz
1,5
dB
max
3
dB
246,0 MHz ± 330
kHz ... 246,0 MHz ± 400
kHz
22
dB
min 18
dB
246,0 MHz ± 400
kHz ... 246,0 MHz ± 600
kHz
33
dB
min 25
dB
246,0 MHz ± 600
kHz ... 246,0 MHz ± 800
MHz
50
dB
min 40
dB
246,0 MHz ± 800
kHz ... 246,0 MHz ± 1,6 MHz
55
dB
min 45
dB
246,0 MHz ± 1,6 MHz ... 246,0 MHz ± 3,0 MHz
55
dB
min 45
dB
246,0 MHz ± 3,0 MHz ... 246,0 MHz ± 20
MHz
55
dB
min 46
dB
246,0 MHz ± 20
MHz ...246,0 MHz ± 100
MHz
55
dB
min 45
dB
______________________________________________________________________________________________________
GDD
Group delay distortion
246,0 MHz ± 50
kHz
0,5
µs
max 1,2
µs
246,0 MHz ± 70
kHz
0,8
µs
max 1,5
µs
246,0 MHz ± 100
kHz
1,2
µs
max 2,5
µs
______________________________________________________________________________________________________
Operating temperature range
- 20 °C ... + 70 °C
Storage temperature range
- 30 °C ... + 85 °C
______________________________________________________________________________________________________
- 0,036 ppm/K²
Temperature coefficient of frequency TCf
______________________________________________________________________________________________________
Frequency inversion temperature
+ 25
°C
______________________________________________________________________________________________________
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
version1.1
tfs246h.eng
06.01.02
______________________________________________________________________________________________________
TELE FILTER tft GmbH
SAW filter specification
TFS 246 H
2/4
______________________________________________________________________________________________________
Construction and pin configuration
(All dimensions in mm)
S 246 H
L4
1 Output
2 Output
3 Ground 4 ext. Coil
5 Ground 6 Ground
7 Input
8 Input
9 Ground 10 Ground
11 Ground 12 Ground
50 Ohm Test circuit 1
LB-IN
L1
8
SAW
C1
LB-OUT
C2
2
7
L3
L2
1
L4
4
3,5,6,9,10,11,12
L5
50 Ohm Test circuit 2
LB-IN
C2
C1
8
SAW
L1
L2
2
7
C3
LB-OUT
1
C4
4
3,5,6,9,10,11,12
L3
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
version1.1
tfs246h.eng
06.01.02
______________________________________________________________________________________________________
TELE FILTER tft GmbH
SAW filter specification
TFS 246 H
3/4
______________________________________________________________________________________________________
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
30g, 18 ms, half sine wave, 3 shocks each plane;
IEC 68 - 2 - 27
2. Vibration:
10 Hz to 150 Hz, 0.35 mm amplitude, 5g; 2 hours for 3 planes;
IEC 68 - 2 - 6
3. Damp heat:
90 % to 95 % rel. humidity, 40 °C, 10 days;
IEC 68 - 2 - 3
4. Resistance to
solder heat (Reflow):
260 °C for 10 sec;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel: 3400
Tape (all dimensions in mm)
W
Po
Do
:
:
:
16
4
1,5
± 0,3
± 0,1
+ 0,5
D1
:
1,5
+ 0,5
E
:
1,75 ± 0,1
F
:
G (min) :
7,5 ± 0,1
0,75
P2
P1
:
:
2
8
D1(min) :
Ao
:
Bo
:
1,5
5,4
7,4
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
F
D1
13,4
± 0,1
W
Bo
± 0,05
± 0,1
G
P1
± 0,1
± 0,1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
>= 90
C
C
:
13
± 0,25
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
version1.1
tfs246h.eng
06.01.02
______________________________________________________________________________________________________
TELE FILTER tft GmbH
SAW filter specification
TFS 246 H
4/4
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.