OPEN FRAME & ENCLOSED SNA D C F I LT E R Features • • • • Ripple noise attenuation type for switch mode power supplies (DC). ±50Vdc. Best filter for switch mode power supplies for analog Circuits. Din rail installation type (Option). Specifications Ordering Information INPUT Voltage ±50Vdc (+Vin – COM-in, -Vin – COM-in) Test voltage (Terminal-mounting plate) 500Vac (cutoff current = 100mA), 1 minute at room temperature and humidity. Isolation resistance (Terminal-mounting plate) 500Vdc, 50MW minute at room temperature and humidity. OUTPUT Current See table. DC resistance (mW) 190mW max. (SNA-01) 90mW max. (SNA-03) 50mW max. (SNA-06) Leakage current 2.5mA/5.0mA max (125/250Vac, 60Hz) -01 (2) -223 (3) CURRENT 01 1A ENVIRONMENTAL 03 3A Operating temperature -40°C to 71°C (Refer to derating curve). 06 6A Storage temperature -40°C to 75°C Humidity 20% to 95% RH (Non-condensing) Vibration Impact Safety _ (4) 1. Model name 2. Rated current 3. Line to ground capacitor code 4. Options D: Din rail installation type. T: Terminal block type. (SNA-06 only) DT: Terminal block and Din rail type. (SNA-06 only). CODE CODE LINE TO GROUND CAPACITOR (NOMINAL VALUE) 10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1 hour each X, Y and Z axis. 000 Not Provided 196.1m/s2 (20G), 11ms once each X, Y and Z axis. 223 22000pF STANDARDS 144 SNA (1) UL60950-1, C-UL (CSA60950-1), EN60950-1.