MICREL SY89218UHY

SY89218U
Precision 1:15 LVDS Fanout Buffer with 2:1
MUX and Four ÷1/÷2/÷4 Clock Divider Output
Banks
General Description
Features
The SY89218U is a 2.5V precision, high-speed,
integrated clock divider and LVDS fanout buffer capable
of handling clocks up to 1.5GHz. Optimized for
communications applications, the four independently
controlled output banks are phase-matched and can be
configured for pass through (÷1), ÷2 or ÷4 divider ratios.
The differential input includes Micrel’s unique, 3-pin
input termination architecture that allows the user to
interface to any differential signal (AC- or DC-coupled)
as small as 100mV (200mVPP) without any level shifting
or termination resistor networks in the signal path. The
low-skew, low-jitter outputs are LVDS compatible with
extremely fast rise/fall times guaranteed to be less than
200ps.
The /MR (master reset) input asynchronously resets the
outputs. A four-clock delay after de-asserting /MR allows
the counters to synchronize and start the outputs from
the same state without any runt pulse.
®
The SY89218U is part of Micrel’s Precision Edge
product family. All support documentation can be found
at Micrel's web site at: www.micrel.com.
• Low-skew LVDS output banks with independently
programmable ÷1, ÷2 and ÷4 divider options
• Four output banks, 15 total outputs
• Guaranteed AC performance over temperature and
voltage:
– Accepts a clock frequency up to 1.5GHz
– <1600ps IN-to-OUT propagation delay
– <200ps rise/fall time
– <35ps within bank skew
• Fail Safe Input
– Prevents outputs from oscillating
• Ultra-low jitter design:
– <1psRMS random jitter
– <10psPP total jitter (clock)
• Patent-pending input termination and VT pin accepts
DC- and AC-coupled inputs (CML, PECL, LVDS)
• LVDS-compatible outputs
• CMOS/TTL-compatible output enable (EN) and
divider select control
• 2.5V ±5% power supply
• –40°C to +85°C temperature range
• Available in 64-pin TQFP
Applications
• All SONET/SDH applications
• All Fibre Channel applications
• All Gigabit Ethernet applications
Markets
•
•
•
•
LAN/WAN routers/switches
Storage
ATE
Test and measurement
Precision Edge is a registered trademark of Micrel, Inc.
Micrel Inc. • 2180 Fortune Drive • San Jose, CA 95131 • USA • tel +1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com
January 2007
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Functional Block Diagram
January 2007
2
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Ordering Information(1)
Part Number
Package
Type
Operating
Range
Package Marking
Lead
Finish
SY89218UHY
T64-1
Industrial
SY89218UHY with
Pb-Free bar-line indicator
Pb-Free
Matte-Sn
T64-1
Industrial
SY89218UHY with
Pb-Free bar-line indicator
Pb-Free
Matte-Sn
SY89218UHYTR
(2)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
Pin Configuration
64-Pin EPAD-TQFP (T64-1)
January 2007
3
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Pin Description
Pin Number
Pin Name
1, 2
3, 4
15, 16
17, 18
FSELA1, FSELA0
FSELB1, FSELB0
FSELC1, FSELC0
FSELD1, FSELD0
5, 8,
11, 14
IN0, /IN0
IN1, /IN1
Differential Inputs: These input pairs are the differential signal inputs to the device.
These inputs accept AC- or DC-coupled signals as small as 100mV. The input pairs
internally terminate to a VT pin through 50Ω. Note that these inputs will default to an
indeterminate state if left open. Please refer to the “Input Interface Applications”
section for more details.
6, 12
VT0, VT1
Input Termination Center-Tap: Each side of a differential input pair terminates to a VT
pin. The VT pin provides a center-tap to a termination network for maximum interface
flexibility. See “ Input Interface Applications” section for more details.
7,
13
VREF-AC0,
VREF-AC1
Reference Voltage: These outputs bias to VCC–1.2V. They are used for AC-coupling
inputs IN and /IN. Connect VREF-AC directly to the corresponding VT pin. Bypass with
0.01µF low ESR capacitor to VCC. Due to limited drive capability, the VREF-AC pin is
only intended to drive its respective VT pin. Maximum sink/source current is ±1.5mA.
Please refer to the “Input Interface Applications” section for more details.
9
/MR
Single-Ended Input: This TTL/CMOS-compatible master reset function asynchronously
sets the true outputs LOW, complimentary outputs HIGH, and holds them in that state
as long as /MR remains LOW. This input is internally connected to a 25kΩ pull-up
resistor and will default to logic HIGH state if left open. The input-switching threshold is
VCC/2.
10
CLK_SEL
Single-Ended Input: This single-ended TTL/CMOS-compatible input selects the inputs
to the multiplexer. Note that this input is internally connected to a 25kΩ pull-up resistor
and will default to logic HIGH state if left open. The input-switching threshold is VCC/2.
20, 25, 30, 33,
40
41, 48, 50, 55,
62
VCC
Positive Power Supply. Bypass with a 0.1µF||0.01µF low ESR capacitor as close to
VCC pin as possible.
21, 22
23, 24
26, 27
28, 29
/QC0, QC0
/QC1, QC1
/QC2, QC2
/QC3, QC3
Bank C LVDS differential output pairs controlled by FSELC1 and FSELC0. Refer to
“Function Table” for details. Unused output pairs should be terminated with 100Ω
across the differential pair
31
NC
34, 35,
36, 37
38, 39,
42, 43
44, 45,
46, 47
/QD0, QD0
/QD1, QD1
/QD2, QD2
/QD3, QD3
/QD4, QD4
/QD5, QD5
Bank D LVDS differential output pairs controlled by FSELD1 and FSELD0. Refer to
“Function Table” for details. Unused output pairs should be terminated with 100Ω
across the differential pair
51, 52
53, 54
/QA0, QA0
/QA1, QA1
Bank A LVDS differential output pairs controlled by FSELA1 and FSELA0. Refer to
“Function Table” for details. Unused output pairs should be terminated with 100Ω
across the differential pair
56, 57
58, 59
60, 61
/QB0, QB0
/QB1, QB1
/QB2, QB2
Bank B LVDS differential output pairs controlled by FSELB1 and FSELB0. Refer to
“Function Table” for details. Unused output pairs should be terminated with 100Ω
across the differential pair
January 2007
Pin Function
Single-Ended Inputs: These TTL/CMOS inputs select the divide ratio for each of the
four banks of outputs. Note that each of these inputs is internally connected to a 25kΩ
pull-up resistor and will default to a logic HIGH state if left open. The input-switching
threshold is VCC/2.
No connect.
4
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Pin Description (continued)
Pin Number
Pin Name
64
EN
19, 32, 49, 63
GND,
Exposed Pad
Pin Function
Single-Ended Input: This TTL/CMOS input disables and enables the outputs. It is
internally connected to a 25kΩ pull-up resistor and will default to logic HIGH state if left
open. When disabled, true outputs go LOW and complementary outputs switch to HIGH.
The input switching threshold is VCC/2. For the input enable and disable functional
description, refer to Figures 2d and 2e.
Ground and exposed pad must be connected to the same GND plane on the board.
Function Table
/MR
(1)
(2, 3)
EN
CLK_SEL
FSELx0
(4)
FSELx1
(4)
Q
1
1
0
0
0
IN0÷1
1
1
1
0
0
IN1÷1
1
1
0
1
0
IN0÷2
1
1
1
1
0
IN1÷2
1
1
0
X
1
IN0÷4
1
1
1
X
1
IN1÷4
1
0
X
X
X
0
0
X
X
X
X
0
Notes:
1.
/MR asynchronously forces Q to LOW (/Q to HIGH).
2.
EN forces Q LOW between 2 and 6 input clock cycles after the falling edge of EN. Refer to “Timing Diagram” section.
3.
EN synchronously enables Q between two and six input clock cycles after the rising edge of EN. Refer to “Timing Diagram” section.
4.
FSEL valid for each of the banks A, B, C, and D. Banks can be programmed independent of each other.
January 2007
5
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Absolute Maximum Ratings(1)
Operating Ratings(2)
Supply Voltage (VCC) ................................. –0.5V to +4.0V
Input Voltage (VIN) ......................................... –0.5V to VCC
Termination Current
Source or sink current on VT ......................... ±100mA
Input Current
Source or sink current on IN, /IN..................... ±50mA
(3)
VREF-AC Current
Source or sink current on VREF-AC...................... ±2mA
Lead Temperature (soldering, 20sec.)…………….260°C
Storage Temperature (Ts)……………...–65°C to +150°C
Supply Voltage (VIN) .......................+2.375V to +2.625V
Ambient Temperature (TA) ....................–40°C to +85°C
(4)
Package Thermal Resistance
TQFP
Still-air (θJA)...............................................35°C/W
Junction-to-board (ψJB) ............................20°C/W
DC Electrical Characteristics(5)
VCC = +2.5V ±5%, TA = –40°C to +85°C, unless otherwise stated.
Symbol
Parameter
VCC
Positive Supply Voltage Range
ICC
Power Supply Current
RDIFF_IN
Differential Input Resistance
(IN-to-/IN)
RIN
Condition
Min
Typ
Max
Units
2.625
V
325
420
mA
90
100
110
Ω
Input Resistance
(IN-to-VT, /IN-to-VT)
45
50
55
Ω
VIH
Input HIGH Voltage (IN, /IN)
1.2
VCC
V
VIL
Input LOW Voltage (IN, /IN)
0
VIH–0.1
V
VIN
Input Voltage Swing (IN, /IN)
See Figure 1a, Note 6
0.1
2.5
VDIFF_IN
Differential Input Voltage Swing
|IN – /IN|
See Figure 1b
200
VIN_FSI
Input Voltage Threshold that
Triggers FSI
VREF-AC
Reference Voltage
VT_IN
Voltage from Input to VT
2.375
VCC–1.3
V
mV
30
100
mV
VCC–1.2
VCC–1.1
V
1.28
V
Max
Units
LVTTL/CMOS DC Electrical Characteristics(5)
VCC = +2.5V ±5%, TA = –40°C to +85°C, unless otherwise stated.
Symbol
Parameter
Condition
Min
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
IIH
Input HIGH Current
–125
IIL
Input LOW Current
-300
Typ
2
V
0.8
V
30
µA
µA
Notes:
1. Permanent device damage may occur if absolute maximum ratings are exceeded. This is a stress rating only and functional operation is not
implied at conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum ratings conditions for
extended periods may affect device reliability.
2. The data sheet limits are not guaranteed if the device is operated beyond the operating ratings.
3. Due to the limited drive capability use for input of the same package only.
4. ψJB and θJA values are determined for a 4-layer board in still-air number, unless otherwise stated.
5. The circuit is designed to meet the DC specifications shown in the above table after thermal equilibrium has been established.
6. VIN(max) is specified when VT is floating.
January 2007
6
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
LVDS Outputs DC Electrical Characteristics(7)
VCC = +2.5V ±5%, RL = 100_ across the outputs; TA = –40°C to +85°C, unless otherwise stated.
Symbol
Parameter
Condition
Min
Typ
Max
Units
VOUT
Output Voltage Swing (Q, /Q)
See Figure 1a
250
325
mV
VDIFF_OUT
Differential Output Voltage Swing
|Q – /Q|
See Figure 1b
500
650
mV
VOCM
Output Common Mode Voltage
(Q, /Q)
See Figure 5b
1.125
1.20
ΔVOCM
Change in Common Mode Voltage
(Q, /Q)
See Figure 5b
–50
1.275
V
+50
mV
Notes:
7. The circuit is designed to meet the DC specifications shown in the above table after thermal equilibrium has been established.
January 2007
7
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
AC Electrical Characteristics(8)
VCC = +2.5V ±5%, RL = 100_ across the outputs; TA = –40°C to +85°C, unless otherwise stated.
Symbol
Parameter
Condition
Min
Typ
fMAX
Maximum Operating Frequency
VOUT ≥ 200mV
1.5
2
tPD
Differential Propagation Delay
IN-to-Q
800
1250
1600
ps
CLK_SEL-to-Q
700
1000
1400
ps
/MR(H-L)-to-Q
700
1000
1400
ps
/MR (L-H)-to-IN
300
tRR
Reset Recovery Time
tPD
Tempco
Differential Propagation Delay
Temperature Coefficient
tSKEW
Within-Bank Skew
Bank-to-Bank Skew
tJITTER
tr, tf
Max
GHz
ps
225
(9. 10)
Within same fanout bank
Same divide setting
Units
(11)
(11)
fs/°C
35
ps
40
ps
Bank-to-Bank Skew
Different divide setting
60
ps
Part-to-Part Skew
Note 12
400
ps
Random Jitter (RJ)
Note 13
1
psRMS
Total Jitter (TJ)
Note 14
10
psPP
Cycle-to-Cycle Jitter
Note 15
Output Rise/Fall Time
(20% to 80%)
At full output swing
60
Duty Cycle
Divide-by-2 or Divide-by-4
Divide-by-1, input > 1GHz
Divide-by-1, input < 1GHz
1
psRMS
200
ps
47
53
%
45
55
%
47
53
%
120
Notes:
8.
Measured with 100mV input swing. Input tr,/tf < 300ps. See “Timing Diagrams” section for definition of parameters. High-frequency ACparameters are guaranteed by design and characterization.
9.
Within-bank skew is the difference in propagation delays among the outputs within the same bank.
10. Skews within banks depend on the number of outputs. Within-bank skew decreases if the bank has lesser outputs.
11. Bank-to-bank skew is the difference in propagation delays between outputs from different banks. Bank-to-bank skew is also the phase offset
between each bank, after MR is applied.
12. Part-to-part skew is defined for two parts with identical power supply voltages at the same temperature and with no skew of the edges at the
respective inputs.
13. Random jitter is measured with a K28.7 comma detect character pattern.
12
14. Total jitter definition: with an ideal clock input frequency ≤ fMAX, no more than one output edge in 10 output edges will deviate by more than the
specified peak-to-peak jitter value.
15. Cycle-to-cycle jitter definition: the variation of periods between adjacent cycles, Tn–Tn–1 where T is the time between rising edges of the output
signal.
January 2007
8
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Master Reset (/MR)
/MR is a TTL/CMOS compatible input that resets the
output signals. Internal 25k_ pull-up resistor defaults
the input to logic HIGH if left open. A LOW input to
/MR asynchronously sets the true outputs LOW and
complimentary outputs HIGH. The outputs will remain
in this state until /MR is forced HIGH. Input switching
threshold is VCC/2. Refer to Figure 2c.
Enable Outputs (EN)
EN is a synchronous TTL/CMOS compatible input that
enables/disables the outputs based on the input to
this pin. Internal 25k_ pull-up resistor defaults the
input to logic HIGH if left open. A logic LOW input
causes the true outputs to go LOW and
complementary outputs to go HIGH. It takes 2 to 6
input clock cycles before the outputs are
enabled/disabled because the signals are going
through a series of flip-flops. Input switching threshold
is VCC/2. Refer to Figure 2d and 2e.
Functional Description
Clock Select (CLK_SEL)
CLK_SEL is an asynchronous TTL/CMOS compatible
input that selects one of the two input signals. Internal
25k_ pull-up resistor defaults the input to logic HIGH if
left open. Delay between the clock selection and
multiplexer selecting the correct input signal depends
upon the divider settings. The delay varies due to the
asynchronous nature of the input. Input switching
threshold is VCC/2. Refer to Figure 2a.
Fail-Safe Input (FSI)
The input includes a special failsafe circuit to sense
the amplitude of the input signal and to latch the
outputs when there is no input signal present, or when
the amplitude of the input signal drops sufficiently
below 100mVPK (200mVPP), typically 30mVPK.
Maximum frequency of the SY89218U is limited by the
FSI function. Refer to Figure 2b.
Input Clock Failure Case
If the input clock fails to a floating, static, or extremely
low signal swing, the FSI function will eliminate a
metastable condition and guarantee a stable output
signal. No ringing and no undetermined state will
occur at the output under these conditions.
Please note that the FSI function will not prevent duty
cycle distortion in case of a slowly deteriorating (but
still toggling) input signal. Due to the FSI function, the
propagation delay will depend upon rise and fall time
of the input signal and on its amplitude. Refer to
“Typical Operating Characteristics” for detailed
information.
January 2007
9
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Single-Ended Differential Swings
Figure 1a. Single-Ended Voltage Swing
Figure 1b. Differential Voltage Swing
Timing Diagrams
Figure 2a. Propagation Delay
Figure 2b. Fail Safe Feature
January 2007
10
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Timing Diagrams
Figure 2c. Reset with Output Enabled
January 2007
11
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Timing Diagrams
Figure 2d. Enable Timing
Figure 2e. Disable Timing
January 2007
12
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Typical Operating Characteristics
VCC = 2.5V, GND = 0V, VIN = 100mV, RL = 100Ω across the outputs, TA = 25°C, unless otherwise stated.
January 2007
13
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Functional Characteristics
VCC = 2.5V, GND = 0V, VIN = 100mV, RL = 100Ω across the outputs, TA = 25°C, unless otherwise stated.
January 2007
14
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Input Stage Internal Termination
Figure 3. Simplified Differential Input Stage
Input Interface Applications
Figure 4a. CML Interface
(DC-Coupled)
Figure 4b. CML Interface
(AC-Coupled)
Figure 4c. LVPECL Interface
(DC-Coupled)
Option: May connect VT to VCC
Figure 4d. LVPECL Interface
(AC-Coupled)
January 2007
Figure 4e. LVDS Interface
15
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
LVDS Output Interface Applications
LVDS specifies a small swing of 325mV typical, on a
nominal 1.2V common mode above ground. The
common mode voltage has tight limits to permit large
variations in the ground between and LVDS driver and
receiver. Also, change in common mode voltage, as a
function of data input, is kept to a minimum, to keep
EMI low.
Figure 5b. LVDS Common Mode Measurement
Figure 5a. LVDS Differential Measurement
January 2007
16
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Related Product and Support Documentation
Part
Number
Function
Data Sheet Link
SY89221U
Precision 1:15 LVPECL Fanout
Buffer with 2:1 MUX and Four
÷1/÷2/÷4 Clock Divider Output
Banks
http://www.micrel.com/_PDF/HBW/sy89221u.pdf
SY89200U
Ultra-Precision 1:8 LVDS Fanout
with Three ÷1/÷2/÷4 Clock Divider
Output Banks
http://www.micrel.com/_PDF/HBW/sy89200u.pdf
SY89202U
Ultra-Precision 1:8 LVPECL
Fanout with Three ÷1/÷2/÷4 Clock
Divider Output Banks
http://www.micrel.com/_PDF/HBW/sy89202u.pdf
HBW
Solutions
New Products and Applications
http://www.micrel.com/page.do?page=/product-info/as/HBWsolutions.shtml
January 2007
17
M9999-012407-B
[email protected] or (408) 955-1690
Micrel, Inc.
SY89218U
Package Information
64-Pin EPAD-TQFP (T64-1)
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL +1 (408) 944-0800 FAX +1 (408) 474-1000 WEB http:/www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for
its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a
product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for
surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant
injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is a Purchaser’s own risk
and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
January 2007
18
M9999-012407-B
[email protected] or (408) 955-1690