VECTRON TFS135C

TFS 135C.doc
version 2.0
VI TELEFILTER
Filter Specification
22.03.01
TFS 135 C
1/5
1. Measurement condition
Ambient temperature TA:
Input power level:
Terminating impedances at fc:
23 °C
0 dBm
for input:
for output:
50 Ω  -19,2 pF
50 Ω  -16,4 pF
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 135C is the insertion loss. The minimum of the pass band attenuation amin is defined as
the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of
the filter in the operating temperature range.
Data
typ. value
tolerance / limit
max
Insertion loss (Reference level)
ae
14,6
Centre frequency
fc
-
Relative attenuation
arel
dB
15,5
135,420 MHz ± 60
kHz
fc ±
1,25 MHz
max
3
dB
fc ±
4
MHz
fc ± 15 MHz
45...48
dB
min
40
dB
fc ±
15
MHz
fc ± 25 MHz
50...60
dB
min
38
dB
80
ns
Group delay ripple:
-
dB
fc ± 1,0 MHz
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature T:
Operating Temperature Range
Generated:
-19
ppm/K
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
- 10 °C ... + 85
°C
_____________
Checked/Approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
VI TELEFILTER
Filter Specification
TFS 135 C
22.03.01
2/5
3. Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
N06
S 135C
Datecode
L
M
N
...
Year+week
1999
2000
2001
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Output
Ground
Ground
Ground
Ground
Ground
Input
Ground
Ground
Ground
50 Ω test circuit
9
IN
L1
3
SAW
L2
OUT
1,2,4,5,6,7,8,10,11,12
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
VI TELEFILTER
Filter Specification
TFS 135 C
22.03.01
3/5
4. Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
5. Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Reel of empty components at start:
Reel of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
:
16
± 0,3
Po
:
4
± 0,1
Do
:
1,5 + 0,1
E
:
1,75 ± 0,1
F
:
7,5 ± 0,1
2000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
G (min) :
0,6
P2
:
2
± 0,1
P1
± 0,1
:
8
D1(min) :
1,5
Ao
:
5,5
± 0,1
Bo
:
7,5
± 0,1
CT
:
F
D1
CT
W
Bo
G
13,5 + 0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
:
330
16,4 +2
W2 (max) :
22,4
N (min)
:
50
C
:
13 +0,5 / -0,2
A
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the
sprocket holes.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
version 2.0
VI TELEFILTER
Filter Specification
22.03.01
TFS 135 C
4/5
6. Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °
main-heating periods
Cover 200 °C
60 sec. - 90 sec.
peak temperature
255 °C ± 5 °C
20 sec. - 25 sec.
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
TFS 135C.doc
VI TELEFILTER
version 2.0
Filter Specification
22.03.01
TFS 135 C
5/5
7. History
Version
Reason of Changes
Name
Date
1.0
- generate specification
Pfeiffer
09.02.01
2.0
- new definition of insertion loss (minimum of the passband attenuation)
Pfeiffer
- new teminating impedances at fC
- fC = 135,420 MHz ± 60 kHz
- change from nominal frequency to centre frequency as basis for relative attenuation
- ae = 15,5 dB
- group delay ripple = 80 ns
22.03.01
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information