TFS 135C.doc version 2.0 VI TELEFILTER Filter Specification 22.03.01 TFS 135 C 1/5 1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 23 °C 0 dBm for input: for output: 50 Ω -19,2 pF 50 Ω -16,4 pF 2. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 135C is the insertion loss. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. Data typ. value tolerance / limit max Insertion loss (Reference level) ae 14,6 Centre frequency fc - Relative attenuation arel dB 15,5 135,420 MHz ± 60 kHz fc ± 1,25 MHz max 3 dB fc ± 4 MHz fc ± 15 MHz 45...48 dB min 40 dB fc ± 15 MHz fc ± 25 MHz 50...60 dB min 38 dB 80 ns Group delay ripple: - dB fc ± 1,0 MHz Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature T: Operating Temperature Range Generated: -19 ppm/K ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) - 10 °C ... + 85 °C _____________ Checked/Approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 135C.doc version 2.0 VI TELEFILTER Filter Specification TFS 135 C 22.03.01 2/5 3. Construction, pin configuration and 50 Ω - matching network (All dimensions in mm) N06 S 135C Datecode L M N ... Year+week 1999 2000 2001 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Output Ground Ground Ground Ground Ground Input Ground Ground Ground 50 Ω test circuit 9 IN L1 3 SAW L2 OUT 1,2,4,5,6,7,8,10,11,12 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 135C.doc version 2.0 VI TELEFILTER Filter Specification TFS 135 C 22.03.01 3/5 4. Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 5. Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer Tape (all dimensions in mm) W : 16 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,1 E : 1,75 ± 0,1 F : 7,5 ± 0,1 2000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Do Po P2 E Ao G (min) : 0,6 P2 : 2 ± 0,1 P1 ± 0,1 : 8 D1(min) : 1,5 Ao : 5,5 ± 0,1 Bo : 7,5 ± 0,1 CT : F D1 CT W Bo G 13,5 + 0,1 P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 : 330 16,4 +2 W2 (max) : 22,4 N (min) : 50 C : 13 +0,5 / -0,2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the sprocket holes. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 135C.doc version 2.0 VI TELEFILTER Filter Specification 22.03.01 TFS 135 C 4/5 6. Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 ° main-heating periods Cover 200 °C 60 sec. - 90 sec. peak temperature 255 °C ± 5 °C 20 sec. - 25 sec. Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS 135C.doc VI TELEFILTER version 2.0 Filter Specification 22.03.01 TFS 135 C 5/5 7. History Version Reason of Changes Name Date 1.0 - generate specification Pfeiffer 09.02.01 2.0 - new definition of insertion loss (minimum of the passband attenuation) Pfeiffer - new teminating impedances at fC - fC = 135,420 MHz ± 60 kHz - change from nominal frequency to centre frequency as basis for relative attenuation - ae = 15,5 dB - group delay ripple = 80 ns 22.03.01 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information