VECTRON TFS380A

tfs380a.doc
version 3.0
VI TELEFILTER
Filter specification
13.03.2001
TFS 380A
1/5
Measurement Condition
Ambient Temperature:
Input Power Level:
Source impedance:
Load impedance:
Terminating impedances:
input:
output:
23
0
50
50
°C
dBm
Ω
Ω
720 Ω || -4.7pF
1000 Ω || -4.1pF
Characteristics
Remark:
Reference level for the relative attenuation arel is the minimum pass band attenuation amin. It is defined as the insertion loss ae. The nominal
frequency fN is fixed to 380,0 MHz. The center frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB filter
attenuation level relative to the insertion loss ae The given values for the insertion loss, the relative attenuation arel and the group delay ripple have
to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the
operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. Value
Insertion Loss
(Reference level)
ae = amin
Nominal Frequency
fN
-
1 dB - Bandwidth
BW
4,2 MHz
Relative Attenuation
arel
fN ± 2,5
fN ± 3,0
fN ± 3,25
fN ± 3,5
fN ± 5,0
MHz
MHz
MHz
MHz
MHz
MHz ... fN ± 3,0
MHz ... fN ± 3,25
MHz ... fN ± 3,5
MHz ... fN ± 5,0
MHz ... fN ± 100,0
Pass Band Ripple
fN ± 2,025 MHz
Group delay ripple
fN ± 2,025 MHz
14,0 dB
5
20
35
38
50
Limit
max.
17
dB
380,0 MHz
min.
4,05 MHz
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
3
10
20
30
40
dB
dB
dB
dB
dB
0,4 dB
max.
1
dB
max. 100
ns
ϕ
Operating Temperature Range
65
ns
- 0 °C ... + 70 °C
Generated:
Checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs380a.doc
version 3.0
VI TELEFILTER
Filter specification
TFS 380A
13.03.2001
2/5
Construction and pin connection
Datecode
S 380 A
N11
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Ground
Input RF Return
Input
Ground
Ground
Datecode:
L
M
N
...
Year+week
1999
2000
2001
50 Ω test circuit
C1
Input
L1
4
10
SAW
C2
L2
C3
Output
C4
3
9
1,2,5,6,7,8,11,12
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs380a.doc
version 3.0
VI TELEFILTER
Filter specification
13.03.2001
TFS 380A
3/5
Stability Characteristics:
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing:
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Reel of empty components at start:
Reel of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
Do
:
:
:
16
4
1,5
E
F
:
:
1,75 ± 0,1
7,5 ± 0,1
G (min) :
P2
:
P1
:
0,6
2 ± 0,1
8 ± 0,1
3000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
± 0,3
± 0,1
+ 0,5
Do
Po
P2
E
Ao
F
D1
W
Bo
Ct
G
D1(min) :
Ao
:
1,5
5,5
± 0,1
Bo
:
7,5
± 0,1
Ct
:
13,5+/-0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
50
C
C
:
13
-
+ 0,5
A
N
0,2
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the
sprocket holes.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs380a.doc
version 3.0
VI TELEFILTER
Filter specification
13.03.2001
TFS 380A
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs380a.doc
version 3.0
VI TELEFILTER
Filter specification
13.03.2001
TFS 380A
5/5
History
Version
Reason of Changes
Name
Date
Development specification
1.0
new generation
Steiner
11.04.2000
2.0
Steiner
04.08.2000
Steiner
13.03.2001
- correction of attenuation specification according to customer needs
- stability characteristics, tape and reel dimensions, air reflow profile added
Filter specification
3.0
- terminating impedances added
- loss definition corrected
- typical values added
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.