RECOM REC15

Features
Regulated
Converters
Description
●
●
●
●
●
●
●
●
15W in 2” x 1” Package
2kVDC and 3kVDC Isolation Options
2:1 or 4:1 Input Voltage Range
Continuous Short Circuit Protection
(power limiting)
Synchronous Rectification on 3.4V & 5.1V outputs
Full SMD internal design
Remote Control Pin
Efficiency to 87%
The REC15-xxxxS_D/M -series offer single and dual regulated outputs in a 2”x1” package with
2kVDC or 3kVDC isolation options and are suitable for higher power industrial applications. Remote on/off control is standard. The converters can deliver 150% rated power for short periods
of time to cope with applications with large capacitive loads or high start up currents. The outputs with 3A load current have raised output voltages to compensate for track losses as standard.
Selection Guide
Part
Number
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
REC15-xx3.4S/H*/M
9-18, 18-36, 36-75
3.4
3000
84-85
3300µF
REC15-xx5.1S/H*/M
9-18, 18-36, 36-75
5.1
3000
86-87
3300µF
REC15-xx12S/H*/M
9-18, 18-36, 36-75
12
1250
85-86
3300µF
REC15-xx15S/H*/M
9-18, 18-36, 36-75
15
1000
85-86
3300µF
REC15-xx05D/H*/M
9-18, 18-36, 36-75
±5
±1500
82-83
±1500µF
REC15-xx12D/H*/M
9-18, 18-36, 36-75
±12
±625
85-86
±1000µF
REC15-xx15D/H*/M
9-18, 18-36, 36-75
±15
±500
85-86
±1000µF
REC15-xx3.4SZ/H*/M
9-36, 18-75
3.4
3000
84-85
3300µF
REC15-xx5.1SZ/H*/M
9-36, 18-75
5.1
3000
87
3300µF
REC15-xx12SZ/H*/M
9-36, 18-75
12
1250
86
3300µF
REC15-xx15SZ/H*/M
9-36, 18-75
15
1000
86
3300µF
REC15-xx05DZ/H*/M
9-36, 18-75
±5
±1500
83
±1500µF
REC15-xx12DZ/H*/M
9-36, 18-75
±12
±625
86
±1000µF
REC15-xx15DZ/H*/M
9-36, 18-75
±15
±500
86
±1000µF
* Standard is /H2 for 2kVDC isolation,
use /H3 for 3kVDC Isolation
2:1
xx = 9-18Vin = 12,
xx = 18-36Vin = 24,
xx = 36-75Vin = 48
Efficiency Max. Cap.
(typ.)
Load
(%)
ECONOLINE
DC/DC-Converter
with 3 year Warranty
15 Watt
2” x 1”
Single & Dual
Output
RoHS
2002/95/EC
6/6
E-224736
EN-60950-1 Certified
UL-60950-1 Certified
REC15/M
4:1
xx = 9-36Vin = 24,
xx = 18-75Vin = 48
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
2:1 or 4:1
Input Filter
PI Network
Output Voltage Accuracy (the Output 3.4V is ±1.2% max.)
Line Voltage Regulation
Load Voltage Regulation
Single
(25% to 100% full load )
Dual
Cross Regulation (100%: 25% to 100% full load )
Output Ripple and Noise (with 100n output capacitor and 20MHz BW)
Start-up time (Nom. Vin at 100% Load)
Operating Frequency (Full Load)
E-166
±0.3% max.
±0.5% max.
±1.2% max.
±5% max.
100mVp-p max.
25ms typ.
300kHz typ.
Efficiency (Nom. Vin at 100% Load)
Minimum Load
Input Surge Voltage (100ms max.)
±1.0% max.
see Selection Guide
0%
36VDC
50VDC
100VDC
cont.
12V Input
24V Input
48V Input
REV: 0/2012
Refer to Application Notes
www.recom-electronic.com
REC15-S_D/H*/M
Series
ECONOLINE
DC/DC-Converter
Specifications cont. (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
/H3 Version
Under Voltage Lockout (2:1)
Under Voltage Lockout (4:1)
(tested for 1 second)
(rated for 1 minute)
(tested for 1 second)
(rated for 1 minute)
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
12V Input
DC-DC on 8.3VDC, DC-DC off 7.9VDC
24V Input
DC-DC on 17.4VDC, DC-DC off 16.7VDC
48V Input
DC-DC on 35.7VDC, DC-DC off 34.3VDC
24V Input
DC-DC on 8.3VDC, DC-DC off 7.9VDC
48V Input
DC-DC on 17.4VDC, DC-DC off 16.7VDC
Isolation Capacitance
1200pF typ.
Isolation Resistance
1 GΩ min.
Overload Protection
150% typ.
Short Circuit Protection
Operating Temperature Range
(free air convection)
Temperature Coefficient
60
40
20
0
-40
using MIL-HDBK 217F
using MIL-HDBK 217F
0
50
100 150
71
Operating Temperature °C
4:1 Converters
100
95% RH
80
Nickel Plated Metal with Non-Conductive Base
Natural convection
20°C/W
100°C
10-55Hz, 2G, 30mins along X,Y & Z
27g
10 pcs per Tube
Detailed Information see
Application Notes chapter "MTBF"
80
Safe Operating Area
4:1
60
40
20
0
-40
0
50 71 90
150
Operating Temperature °C
>700 x 103hours
>150 x 103hours
Certifications
EN General Safety
Report: PS090302950C2
UL General Safety
Report: E248550
EN60950-1:2006
UL 60950-1 1st Ed.
C22.2 No. 60950-1-03
Note: Refer to Application Notes for EMC Class B Filter suggestion
Package Style and Pinning (mm)
50.8
3rd angle
projection
25.4
10.2
dia.
1.0
5.6
2.50
5.08
20.32
15.24
3
1
2
6
Bottom View
10.16
10.16
www.recom-international.com
Pin #
Single
Dual
1
+Vin
+Vin
2
–Vin
–Vin
3
+Vout
+Vout
4
No Pin
Com
5
–Vout
–Vout
6
CTRL
CTRL
XX.X ± 0.5 mm
XX.XX ± 0.35 mm
4
5
Pin Connections
12.70
REV:0/2012
E-167
REC15/M
}
Safe Operating Area
100
±0.05% max.
Relative Humidity
MTBF (+25°C)
(+71°C)
2:1 Converters
-55°C to +105°C
Open or 3.5V<Vr<12V
Short or 0V<Vr<1.2V
DC/DC ON
DC/DC OFF
Case Material
Thermal Impedance
Maximum Case Temperature
Vibration
Package Weight
Packing Quantity
(Ambient Temperature)
Continuous, Auto Restart
-40°C to +65°C (see Graph)
-40°C to +71°C (see Graph)
4:1
2:1
Storage Temperature Range
Remote On/Off
Derating-Graph
Output Power (%)
/H2 Version
Output Power (%)
Isolation Voltage