VECTRON TFS429

Filename: tfs 429.doc
Version 1.3
VI TELEFILTER
22.11.2005
Filter specification
TFS 429
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
230 Ω || -2,6 pF
230 Ω || -2,6 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 429 is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 429,20 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
ae = amin
Insertion loss
(reference level)
1,5
Nominal frequency
fN
-
Centre frequency
fC
429,20
PB
-
Passband
p-p
Pass band ripple
-
6,25
fN
fN
fN
fN
fN
+
+
+
419,20
4,20
2,30
3,80
8,80
dB
max.
3,0
429,20
MHz
dB
MHz
fN ± 6,25 kHz
0,1
dB
max.
1,0
dB
0,1
dB
max.
1,0
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
40
25
30
25
35
dB
dB
dB
dB
dB
max.
10
dBm
arel
Relative attenuation
fN
tolerance / limit
kHz
… fN
+
6,25
kHz
MHz
MHz
MHz
MHz
MHz
…
…
…
…
…
+
+
+
4,20
1,70
3,80
8,80
70,80
MHz
MHz
MHz
MHz
MHz
fN
fN
fN
fN
fN
-
Input power level
Operating temperature range
OTR
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
58
43
53
36
50
TCf **
-
- 40 °C ... + 85°C
-
- 45 °C ... + 85°C
24
°C
-0,034
ppm/K
2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 429.doc
Version 1.3
VI TELEFILTER
22.11.2005
Filter specification
TFS 429
2/5
Filter characteristic
0
0
-0.5
-10
-1
-20
magnitude in dB
magnitude in dB
-1.5
-2
-2.5
-3
-30
-40
-50
-3.5
-60
-4
-70
-4.5
-5
428.8
428.9
429
429.1
429.2
frequency in MHz
429.3
429.4
429.5
415
420
425
430
frequency in MHz
435
440
Construction and pin connection
(All dimensions in mm)
7
S429
● T47
1
SQ 3,81 +0,2/-0,1
5
3
1
2
3
4
5
6
7
8
Input
Input RF Return
Ground
Ground
Output
Output RF Return
Ground
Ground
Date code:
T
U
V
...
Year + week
2005
2006
2007
7
5
0,1
12
0%
0,6
%
d
3
1,78
2,54
1
1,2 Max.
Date code
1,78
50 Ω Test circuit
L1
1
5
L2
SAW
C2
C1
2, 3, 4, 6, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 429.doc
Version 1.3
VI TELEFILTER
22.11.2005
Filter specification
TFS 429
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,5 ± 0,1
P1
t
Po
PIN Marker
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Date Code
Typ
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 429.doc
Version 1.3
VI TELEFILTER
22.11.2005
Filter specification
TFS 429
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 429.doc
VI TELEFILTER
Version 1.3
Filter specification
22.11.2005
TFS 429
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Strehl
09.09.2005
1.1
- Add of matching circuit
Sabah
22.09.2005
1.2
- Change construction
- Add typ. value and filter characteristic
- Generation of filter specification
Strehl
11.10.2005
1.3
- Add frequency inversion temperature and change TCf
- Change stability characteristics, reliability
Strehl
22.11.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.