Filename: tfs 429.doc Version 1.3 VI TELEFILTER 22.11.2005 Filter specification TFS 429 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 230 Ω || -2,6 pF 230 Ω || -2,6 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 429 is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 429,20 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value ae = amin Insertion loss (reference level) 1,5 Nominal frequency fN - Centre frequency fC 429,20 PB - Passband p-p Pass band ripple - 6,25 fN fN fN fN fN + + + 419,20 4,20 2,30 3,80 8,80 dB max. 3,0 429,20 MHz dB MHz fN ± 6,25 kHz 0,1 dB max. 1,0 dB 0,1 dB max. 1,0 dB dB dB dB dB dB min. min. min. min. min. 40 25 30 25 35 dB dB dB dB dB max. 10 dBm arel Relative attenuation fN tolerance / limit kHz … fN + 6,25 kHz MHz MHz MHz MHz MHz … … … … … + + + 4,20 1,70 3,80 8,80 70,80 MHz MHz MHz MHz MHz fN fN fN fN fN - Input power level Operating temperature range OTR Storage temperature range Frequency inversion temperature Temperature coefficient of frequency 58 43 53 36 50 TCf ** - - 40 °C ... + 85°C - - 45 °C ... + 85°C 24 °C -0,034 ppm/K 2 - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 429.doc Version 1.3 VI TELEFILTER 22.11.2005 Filter specification TFS 429 2/5 Filter characteristic 0 0 -0.5 -10 -1 -20 magnitude in dB magnitude in dB -1.5 -2 -2.5 -3 -30 -40 -50 -3.5 -60 -4 -70 -4.5 -5 428.8 428.9 429 429.1 429.2 frequency in MHz 429.3 429.4 429.5 415 420 425 430 frequency in MHz 435 440 Construction and pin connection (All dimensions in mm) 7 S429 ● T47 1 SQ 3,81 +0,2/-0,1 5 3 1 2 3 4 5 6 7 8 Input Input RF Return Ground Ground Output Output RF Return Ground Ground Date code: T U V ... Year + week 2005 2006 2007 7 5 0,1 12 0% 0,6 % d 3 1,78 2,54 1 1,2 Max. Date code 1,78 50 Ω Test circuit L1 1 5 L2 SAW C2 C1 2, 3, 4, 6, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 429.doc Version 1.3 VI TELEFILTER 22.11.2005 Filter specification TFS 429 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,5 ± 0,1 P1 t Po PIN Marker P2 W G Ct Bo F G E Do Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 429.doc Version 1.3 VI TELEFILTER 22.11.2005 Filter specification TFS 429 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 429.doc VI TELEFILTER Version 1.3 Filter specification 22.11.2005 TFS 429 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 09.09.2005 1.1 - Add of matching circuit Sabah 22.09.2005 1.2 - Change construction - Add typ. value and filter characteristic - Generation of filter specification Strehl 11.10.2005 1.3 - Add frequency inversion temperature and change TCf - Change stability characteristics, reliability Strehl 22.11.2005 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.