Filename: tfs 922.doc Version 1.3 VI TELEFILTER 24.07.2006 Filter specification TFS 922 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 0 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 922 MHz without any tolerance or limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. Value ae Insertion loss within PB 2,0 dB tolerance / limit max. 3,0 dB Nominal frequency fN - 922 MHz Passband PB - 24 MHz aabs Absolute attenuation fN ± 80 MHz ... fN ± 149 MHz 52 dB min. 33,5 dB fN + 149 MHz ... fN + 300 MHz 52 dB min. 48,5 dB 1 MHz … 200 MHz 63 dB min. 50,0 dB MHz … fN - 149 MHz 66 dB min. 55,0 dB 18 ns max. 0,2 µs 200 Group delay ripple within PB p-p IIP3 * Input power level Operating temperature range OTR min. 36 dBm - max. 10 dBm - - 10 °C ... + 75 °C - Storage temperature range Temperature coefficient of frequency - TCf ** - 42 - 40 °C ... + 85 °C ppm/K - *) fin1= fC - 14 MHz; fin2= fC – 14,4 MHz; Pin=0 dBm; fmeasurement1 = fC - 13,6 MHz; fmeasurement2 = fC - 14,8 MHz. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. **) ∆ f(Hz) =TCf(ppm/K) x(T-T0) x fTo (MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 922.doc Version 1.3 VI TELEFILTER 24.07.2006 Filter specification TFS 922 2/5 0 0.5 -2 0.45 -20 -4 0.4 -30 -6 0.35 -40 -8 0.3 -10 0.25 -12 0.2 -70 -14 0.15 -80 -16 0.1 -90 -18 0.05 -50 -60 -100 200 400 600 frequency in MHz 800 1000 -20 892 1200 898 904 910 916 922 928 frequency in MHz 934 940 946 delay in µs 0 -10 magnitude in dB magnitude in dB Filter characteristic 0 952 Construction and pin connection (All dimensions in mm) 7 922 ● U30 1 SQ 3,81 +0,2/-0,1 5 1 2 3 4 5 6 7 8 Ground Input Ground Ground Ground Output Ground Ground Date code: U V W ... Year + week 2006 2007 2008 3 7 5 0,1 12 0% 0,6 % d 3 1,78 2,54 1 1,2 Max. Date code 1,78 50 Ohm Test circuit L1 2 6 L2 SAW 1, 3, 4, 5, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 922.doc Version 1.3 VI TELEFILTER 24.07.2006 Filter specification TFS 922 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,5 ± 0,1 P1 Date Code Do P2 W G Ct Bo F G E t Po Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 922.doc Version 1.3 VI TELEFILTER 24.07.2006 Filter specification TFS 922 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 922.doc VI TELEFILTER Version 1.3 Filter specification 24.07.2006 TFS 922 5/5 History Version Reason of Changes Name Date 1.0 Generation of development specification Springfeldt 14.04.2004 1.1 Change insertion loss change of absolute attenuation Add typical values and filter characteristic generation of filter specification Strehl 20.01.2005 Strehl 30.06.2005 Strehl 24.07.2006 1.2 1.3 Add IIP3 and change stability characteristics Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.