VECTRON TFS92D

Filename: tfs 92d.doc
Version 1.3
VI TELEFILTER
11.04.2006
Filter specification
TFS 92D
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
1260 Ω || -2,5 pF
1260 Ω || -2,5 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 92,025 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative
attenuation arel of the TFS 92D is the insertion loss ae. All specified data are met within the operating temperature range.
Data
typ. value
Insertion loss
(reference level)
ae
2,8
Nominal frequency
fN
-
PB
Passband
Bandwidth
BW
3
dB
Relative attenuation
arel
fN
fN
fN
fN
fN
fN
fN
+
+
1,0
910
900
300
200
500
MHz
kHz
kHz
kHz
kHz
kHz
51
… fN
±
15
kHz
…
…
…
…
…
…
+
+
910
900
300
120
500
1,0
kHz
kHz
kHz
kHz
kHz
MHz
fN
fN
fN
fN
fN
fN
0,5
68
72
62
46
42
58
3,8
Group delay ripple within PB
dB
max.
OTR
Storage temperature range
fN
Temperature coefficient of frequency
TCf **
± 15
1,0
kHz
min.
dB
max.
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
60
70
60
35
25
40
dB
dB
dB
dB
dB
dB
µs
max.
4
µs
max.
10
30
1,0
-
- 20 °C ... + 70°C
- 40 °C ... + 85°C
-0.04
kHz
max.
28
Frequency inversion temperature
dB
dB
Input power level
Operating temperature range
4,0
92,025 MHz
0,5
Pass band ripple
tolerance / limit
dB
kHz
dB
dBm
°C
ppm/K
2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = TCf(ppm/K2) x (T - To)2 x fTo (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 92d.doc
Version 1.3
VI TELEFILTER
11.04.2006
Filter specification
TFS 92D
2/5
Filter characteristic
0
0
20
-10
18
-40
-50
-60
-70
-5
16
14
delay in µs
-30
magnitude in dB
magnitude in dB
-20
-10
-80
12
-90
-100
91.1 91.28 91.46 91.64 91.82 92 92.18 92.36 92.54 92.72 92.9
frequency in MHz
-15
91.98
92
92.02
92.04
frequency in MHz
92.06
10
Construction and pin connection
(All dimensions in mm)
TFS 92D
●
U15
6,8Max.
13,6Max.
2,54 ±0,15
1,5
2,54 ±0,15
1 2 3 4
2,0Max.
1
12
5
11
6
Date code
10 9 8 7
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Ground
Input
Input RF Return
Date code:
U
V
W
...
Year + week
2006
2007
2008
0,1
0,8
50 Ω Test circuit
11
L1
12
C1
5
SAW
L2
6
C2
1, 2, 3, 4, 7, 8, 9, 10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 92d.doc
Version 1.3
VI TELEFILTER
11.04.2006
Filter specification
TFS 92D
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 24,00 +0,30/-0,10
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,10
F
: 11,50 ± 0,10
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50
Ao
: 7,10 ± 0,10
Bo
: 13,90 ± 0,10
Ct
: 21,5 ± 0,1
t
P1
Date Code
Po
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 24,4 +2/-0
W2(max) : 30,4
N(min)
: 60
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 92d.doc
Version 1.3
VI TELEFILTER
11.04.2006
Filter specification
TFS 92D
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 92d.doc
VI TELEFILTER
Version 1.3
Filter specification
11.04.2006
TFS 92D
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generation of development specification
AdH
15.02.2006
1.1
Change passband and relative attenuation from fC to fN
Change characteristics
Strehl
17.02.2006
1.2
Change operating temperature range
Alawneh
28.02.2006
1.3
Generation of filter specification
Add filter characteristic
Add typical values
Martens
11.04.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is