AEROFLEX CT2577

The Future in Microelectronics
35 South Service Road · Plainview, NY 11803
TEL: 516 694-6700 · FAX: 516 694-6715
CIRCUIT TECHNOLOGY
APPLICATION NOTE #108
CT2577 / 79
SmaRT Series
Users Guide
Point of Contact:
John Vanchieri
Tel: (516) 752-2484
APPLICATION NOTE #108
1
Released 9/98
Table of Contents
Contents
Page
Signal Descriptions...............................................................................................................................................3-7
MIL-STD-1553 Bus Interface Signals
Hard Wired Interface Signals
MIL-STD-1760 Signals
Bus Interface Signals
RT Status Word Discrete Inputs
RT Discrete Signals
BC Discrete Signals
Remote Terminal (RT) Mode.............................................................................................................................8-21
Sequence of Operation
Receive Command
Message Illegalization
MIL-STD-1760 Features
1760 Header Word
Signals that Indicate Checksum Failure
Block Transfer Logic
READ (Receive)
DMA Transfer Times
Transmit Command
MIL-STD-1760 Features
Signals that Indicate Checksum Failure
Block Transfer Logic / DMA Transfer Times
WRITE
Changing the Status Word Bits
Device Status
Bit Register
Data Storage and Retrieval in Ram
Sample Software Code
Retriving or Loading Data to Ram
Self Test
Basic Operation
Detailed Operation
Summary of Operation
CT2577/79 RT/BT Memory Map Breakdown .................................................................................................. 22
RT/BT Device Memory Map Code Breakdown Description.....................................................................23-29
RT Status Word Control Sets
BC Control Area
RT/RX BC/TX Mode Area 00 - SA 00 (0) and BC Control
30 RT Receive / BC Transmit Subaddresses - SA 01-1E (1-30)
RT/RX BC/TX Mode Area - SA 1F (31)
RT/BC Control Area
RT/BC Block Transfer Logic (BTL) Control and Self Test Control
RT/TX BC/RX Mode Area - SA 00 (0)
30 RT Transmit / BC Receive Subaddresses -SA 01-1E (1-30)
RT/TX BC/RX Mode Area - SA 1F (31)
Broadcast RT/RX BC/TX Mode Area - SA 00 (0)
30 Broadcast RT Receive / BC Transmit Subaddresses - SA 01-1E (1-30)
Broadcast RT/RX BC/TX Mode Area 1F - SA 1F (31)
CT2577/79 Part Ordering Information .........................................................................................................30-34
CT2577 - MIL-STD-1553 / 1760 Bus Controller / Remote Terminal
CT2579 - McAir Bus Controller / Remote Terminal
CT2577/79 Pinouts...........................................................................................................................................35-41
CT2577-01-xx-F84 - 84 pin Quad Flatpack
CT2577-11-xx-F84 - 84 pin Quad Flatpack
CT2579-01-xx-F84 - 84 pin Quad Flatpack
CT2579-11-xx-F84 - 84 pin Quad Flatpack
CT2577-10-xx-P119 - 110 Pin Grid Array
CT2579-10-xx-P119 - 110 Pin Grid Array
APPLICATION NOTE #108
2
Released 9/98
Signal Descriptions
MIL-STD-1553 Bus Interface Signals
Data0(Bus) Connect to positive side of the external databus transformer for Bus 0
Ndata0(Bus) Connect to negative side of the external databus transformer for Bus 0
Data1(Bus) Connect to positive side of the external databus transformer for Bus 1
Ndata1(Bus) Connect to negative side of the external databus transformer for Bus 1
Hard Wired Interface Signals
AddrA-E
Remote Terminal address inputs for the unit. ADDR A is the least significant bit and
ADDR E is the most significant bit. RT Address inputs for the unit. AddrA is the LSB,
AddrE is the MSB.
AddrP
Parity Bit for the RT Address inputs. AddrP must be set to ODD parity
MACAIR
This signal sets the unit to respond with a status word within 4 uS (dead bus time)
while in Remote Terminal mode. Subaddress 1F is also enabled to be a valid
subaddress for data.
Normally subaddress 00 and 1F are reserved for mode codes.
“1" = 4 uS dead bus response time, subaddress 1F used for data.
“0" = 12 uS response time, subaddress 1F used for mode codes.
NBIT16
Select 8 or 16 bit subsystem data interface. In 8 bit mode only the lower 8 bits of the
databus (DATA 0-7) are used for all data transfers. If left open circuit the device will
default to 16 bit mode.
"0" = 16 Bit Mode
"1" = 8 Bit Mode
VME
Select VME or MULTIBUS subsystem interface. If left open circuit the device will
default to VME mode.
"0" = Multibus Mode
"1" = VME Mode
*WRAPEN
Select Remote Terminal wrap around to subaddress 1E. For this test to work correctly
theunit must be in RT mode. The Bus Controller sends data to subaddress 1E which
remains in the data buffer memory and is available to be sent back on the very next
command by the Bus Controller. The data in the data buffer memory in this mode
does not get transferred to the main RAM. If the very next command is not a transmit
command to subaddress 1E, the data buffer memory is flushed and will respond
normally to the next set of commands. If the wrap around test is enabled, data to
subaddress 1E must be transferred in the correct sequence.
"0" = Normal Mode
"1" = Wrap Around Mode
MIL-STD-1760 Signals
NENCHK
Enables / Disables the internal hardware checksum generation and validation for both
Remote Terminal and Bus Controller. When enabled, the circuitry will check all
APPLICATION NOTE #108
3
Released 9/98
incoming data for correct checksum and generate the correct checksum word for an
outgoing data transfer.
"0" input to this pin ENABLES the checksum circuitry.
"1" input to this pin Disables the checksum circuitry.
NVALCHK
Latched version of the STATUS signal. NVALCHK is latched on the falling edge of
NCMDSTRB (RT) or NSTSTRB (BC) and will remain stable until the next
NCMDSTRB or NSTSTRB.
"0" output to this pin means the checksum was VALID.
"1" output to this pin means the checksum was NOT VALID.
STATUS
Open drain output will toggle high or low on each incoming data word from the 1553
databus provided NENCHK is enabled. When the last data word is received the
STATUS line is sampled by the protocol circuitry to determine if the checksum for the
message is valid. At the end of the message, if STATUS is low then the checksum is
not valid. This STATUS signal can be wired to several different pins to customise the
units response to achecksum failure. STATUS can be wired to signals such as
NILLCMD and NSR which would cause the message to be illegalised and set Service
Request bit in the Status.
NHDR
In MIL-STD-1760, the first data word of a message is defined as a Header word. The
NHDR signal indicates the presence of the Header word on the T0-T15 highway as it
is received. The user can also read the Header word from RAM.
"0" on this pin means the Header Word is on the T0-15 Bus
STREL
When the store is released from the aircraft all the Remote Terminal address inputs
go high causing signal STREL to go high
LA
Enables the Latched Address Option. Normally, the RT address lines are constantly
monitored and compared to the incoming Command Word. When enabled, the RT
address lines levels are internally latched every time the unit is reset. The latched RT
address information is then compared to the incoming Command Word. This latched
address function complies with the requirements of MIL-STD-1760.
"0" on this pin means the RT address lines are NOT latched
"1" on this pin means the RT address lines are latched
Bus Interface Signals
ADIN0-11
12 bit address input to the unit specifying what location the user will be accessing in the RAM / registers. These address inputs are inverted when the Multibus interface is selected.
BCNRT
Indicates what mode the unit is in.
"0" = RT Mode
"1" = BC Mode
NCARDEN
Used as a Device Select. Signal to indicate the processor is addressing this unit. The
user can use this signal tied to an address decoder to enable the unit for a read/write
operation.
"0" = Enable unit for I/O operations
"1" = DISABLE unit for I/O operations
C16Mhz
16 Mhz clock system clock.
APPLICATION NOTE #108
4
Released 9/98
DATA0-15
16 bit bidirectional data highway access to internal RAM and registers. When in 8 bit
mode only DATA 0-7 are used. Data inputs / outputs are inverted when the Multibus
interface is selected.
NACK
After a write / read cycle has begun, this signal indicates that the write / read
operation to the unit has been acknowledged and that access has been granted.
Read data is available and write data is complete. The user can complete the write /
read cycle.
“0" = Cycle is acknowledged, access granted.
“1" = No acknowledge, wait.
NEMPTY
Empty flag for the Command / Status FIFO memory which can store up to 32
command words (RT) or 32 status words (BC). In RT mode the memory will store all
command words that have accessed the main RAM. This includes all standard
commands to receive and transmit data from the main RAM and mode codes with
data that require subsystem involvement ie. Synchronize With Data and Transmit
Vector Word. In BC mode all status responses are stored in this memory. Access to
this memory is gained by reading from address 0 00 00.
"0" output to this pin means the FIFO is empty (no words).
"1" output to this pin means the FIFO is NOT empty (has words to be read).
NFULL
Full flag for the Command / Status FIFO memory. When the signal goes low the
memoryis full and will not store any more data.
NRES
Bidirectional reset pin. Interface to this pin should be in the form of an open collector
pull down driver. The unit will be reset when a low level input is asserted on power up.
The pin is bidirectional in that the unit will drive the signal out low after the status
response of the mode code Reset Remote Terminal. Upon reset the unit will initialise
to RT mode and will be able to respond immediately after the rising edge of NRES.
T0-15
16 bit bidirectional data highway access to internal RAM and registers. When in 8 bit
mode only DATA 0-7 are used. Data inputs / outputs are inverted when the Multibus
interface is selected. Allows the user to have access to the MIL-STD-1553 bus traffic
in real time. The user can utilize this bus for message illegalization and read words
such as Synch w/Data directly off the T0-15 bus. Utilizing NDATA signal, the user can
read the data words off the T0-15 bus as the DMA burst is transferring the data into
RAM.
UB
Upper byte: When the unit is in 8 bit mode this signal is used as the LSB of the
address lines. In 16 bit mode the signal is not used and the LSB of the address lines
is ADIN 0.
NRD
VME Mode Data Strobe for a data transfer
0 = Read/Write data
1 = Tri-state the Data 0-15 bus
Multibus Mode:Read strobe for a data transfer
0 = Read data FROM the unit TO the Subsystem
1 = Tri-state the Data0-15 bus
NWR
VME Mode Read/Write direction flag for a NRD data strobe
0 = Write data FROM Subsystem TO the Device
1 = Read data FROM Device unit TO the Subsystem
APPLICATION NOTE #108
5
Released 9/98
Multibus Mode:Write strobe for a data transfer
0 = Write data FROM the Subsystem TO the Device
1 = Tri-state the Data0-15 bus
RT Status Word Discrete Inputs
The following signals are inputs to set the appropriate bits in the RT Status word. All inputs are
sampled after the NVCR signal. These RT Status Word inputs should be latched by NVCR and
remain stable until the next NVCR signal. All the inputs listed below are active low. To set any of the
appropriate bits, the user must pull that input "low" ("0")
NME
Message Error, illegalizes message. Command will not be stored in Command /
Status memory and no transfers to / from main RAM will take place. No data will be
transmitted following the status.
NTF
Sets the Terminal Flag bit
NSR
Sets the Service Request bit
NBUSY
Sets the Subsystem Busy bit
NSSFLAG
Sets the Subsystem Flag bit
NDBCA
Sets the Dynamic Bus Control Accept bit in response to the Mode Code “Dynamic
Bus Control Request”
RT Discrete Signals
BCST
Output high indicates command received was a broadcast. Signal will remain high until next
command is received.
"1" = Broadcast Command was received
MCDET
Output high indicates command received was a mode command. Signal will remain high until
next command is received.
"1" = Mode Code Command was received
NCMDSTRB This signal indicates that a completely validated message has been received for
standard subaddress data activity. Mode commands with or without data will not
generate this signal. The NCMDSTRB signal is 8.5 uS long and is an indication that a
DMA burst will initiate at the end of NCMDSTRB to transfer words between the 32
word data memory and the internal main RAM. All subsystem read / writes to the
main RAM that have been acknowledged (NACK = “0") before NCMDSTRB has
begun must now be completed within 8.5 uS. All subsystem read / write requests to
the main RAM initiated after NCMDSTRB has begun will be held off (no
acknowledge) until the DMA cycle has been completed. The length of the DMA cycle
is dependant on the number of words to DMA into RAM. Access to the 32 word BTL
memory is still possible during the DMA cycle by the subsystem. However, transfers
between the BTL memory and the main RAM will be locked out.
NDBC
Active low indicates that the command received by the Remote Terminal was mode
code Dynamic Bus Control. Signal will remain low until next command is received.
APPLICATION NOTE #108
6
Released 9/98
NSYNC
Signal to subsystem indicating receipt of a Synchronize mode commands If the mode
code has an associated data word, it will be available on T0-T15 at this time. If there
is no associated data word, T0-T15 will be zero.
NVCR
Early indication that a Command Word has been received and is being processed.
The Command Word received is available on the T0-15 bus for decoding at this time.
The user can use this signal for message illegalization and to set the RT Status bits.
NDATA
Access to valid data word in real time before being written to RAM. Data word
available on T0-T15 during active low signal.
NILLCMD
Input to illegalise a command to the Remote Terminal with a clear status response.
The signal is sampled after NVCR except non mode code receive commands in
which case it is sampled after the last data word has been received. A low on this
input will illegalise the message, Command will not be stored in the Command /
Status memory and no transfers to / from main RAM will take place. The device will
respond with a clear status unless a bit has been specifically set. No data will be
transmitted following status.
BC Discrete Signals
NNEWBUS A Bus Control sequence may not normally be initiated until the current sequence is
completed, indicated by signal EOT. However, the Bus Control sequence may be
terminated and restarted if NNEWBUS is active low along with write to address 0 00
00 (000h). This feature would only be used in bus switching.
EOT
Indicates that a valid transfer has been completed on the bus selected.
1 = Valid transfer completed
0 = Not yet Completed
ERROR
Indication that an error has occurred either in the information transferred to the unit
from the subsystem or in the transfers on the 1553 data bus. Nature of error is
available by reading from register location 0 00 12 (012h).
1 = Error has occurred
0 = No error
NSTSTRB
This signal goes low for 8.5 uS to indicate a valid transfer has been completed on the
1553 data bus and the received Status word is now available on the T0-T15 highway.
The Status word is also stored in the Command / Status memory at this time. Once
the signal goes high data received by the Bus Controller (RT to BC transfer) will be
transferred to the main RAM from the 32 word data buffer memory. Note: Data
transferred in RT to RT transfers is not stored in the Bus Controllers main RAM.
NNINHST
May be used to illegalise a message just received. Signal can be tied to STATUS for
illegalisation due to 1760 checksum failures. A low will prevent any data received
being transferred to the main RAM, and the Status word will not be stored in the
Command / Status memory.
APPLICATION NOTE #108
7
Released 9/98
Remote Terminal (RT) Mode
SEQUENCE OF OPERATION
The following section describes the sequence of operation for the various commands that
are received by the SmaRT unit in RT Mode.
RECEIVE COMMAND
An incoming command word is verified for all protocol checks (such as parity and bit count).
The verified command word is placed on the T0-15 bus and the NVCR signal is strobed. It is
at this time that a message can be illegalized.
Each successive data word after the command word is placed in an internal buffer FIFO.
This is done to double buffer the incoming data for complete message verification. Only
after the message is completely validated will the data be transferred to the internal RAM.
Otherwise, the contents of the FIFO is automatically flushed. This ensures that only valid
data will ever be read by the subsystem. The transfer from the FIFO to the RAM is
accomplished by a fast DMA burst. The guarantee of only valid data in RAM greatly
simplifies a MIL-STD-1553 RT implementation. Error handling of data is not required by the
subsystem.
The subsystem is allowed the most flexibility to access the RAM without contending with
1553 bus traffic. In 1553, data words are received at a rate of 20 µSec per word or a
maximum time of 640 µSec for a 32 word transfer. Many other systems do not buffer the
incoming data at all. That means that the RAM is periodically being updated with data words
into the RAM for up to 640 µSeconds. If an error occurs, the corrupt data is already in
memory and must be sorted out by the subsystem microprocessor. The Smart unit buffers
the data so that the RAM is completely available to the subsystem until the DMA transfer to
RAM occurs. The possibilities of memory contention is greatly reduced and the contents of
RAM is guaranteed to be valid.
When the entire set of received data words are transferred to the buffer FIFO, the
NCMDSTRB goes low indicating that a completely validated message has been received.
The received Command Word again appears on the T0-15 bus at this time. The end of the
NCMDSTRB strobe will initiate the DMA cycle to transfer the data words from the buffer
FIFO to internal RAM. The NCMDSTRB pulse is 8.5 µSec long and during this time interval,
the bus arbitration logic is active. If the subsystem has already begun a read/write operation
before NCMDSTRB, the NACK (acknowledge) signal will go low for 500 nSec allowing the
completion of the read/write command. The read/write operation must be completed within
the remaining 8 µSec. If a read/write operation starts after the NCMDSTRB strobe has
begun, the NACK will not occur and thus hold off the subsystem for the duration of the DMA
cycle to internal RAM.
During NCMDSTRB, the Command Word is loaded into the Command/Status FIFO stack
and the NEMPTY line goes high. The user can utilize this signal as an indication that some
activity has occurred. The Command/Status FIFO stores up to 32 command words for the
subsystem to review. This allows the processor to only response to the 1553 unit when
something has occurred. Constant polling of the 1553 unit is not required. To reduce
APPLICATION NOTE #108
8
Released 9/98
processor intervention even further, the Command/Status FIFO will only store commands
that have associated data with it.
MESSAGE ILLEGALIZATION
Any message can be illegalized by applying an active low on the NME signal within 600
nSec of the rising edge of NVCR at this time. If NME signal is pulled low, the RT will respond
with a Status word having the Message Error bit set.
CMD WD
T0-15
NVCR
NME
500 nSec
600 nSec
Max
One way to implement this function is to place a latching PROM to the T0-T10 data bus. The
PROM would only have to decode 11 bits (5 bits subaddress, 5 bits word count, 1 bit T/R)
and have a one bit output to place a high/low level on the NME input pin. The upper five bits
(T11-T15) are just the Remote Terminal address for the unit which is a constant so no
decode of these bits are necessary. The latching signal for the PROM would be the NVCR
line. The NME pin will be read and acted upon 600 nSec after the rising edge of NVCR. The
NME signal would remain latched and stable until the next rising edge of NVCR.
MIL-STD-1760 FEATURES
To enable the 1760 features checksum validation, the NENCHK line is held low. This
enables the integrated on-chip hardware checksum features. The hardware automatically
checks the incoming message for the correct checksum.
1760 HEADER WORD
The signal NHDR will be an early indicator of the 1760 header word. This headerword will
appear on the T0-15 bus when the NHDR signal is low. The NHDR signal will go low on
every header word (first data word) even if the 1760 checksum circuitry is enabled or not.
NHDR is just an indicator of the first data word on the bus T0-15.
1760 HDR WD
T0-15
NHDR
500 nSec
APPLICATION NOTE #108
9
Released 9/98
SIGNALS THAT INDICATE CHECKSUM FAILURE
For 1760 applications, the STATUS line indicates if a message has failed checksum. The
STATUS line will toggle up or down for each received data word as it is calculating the
checksum and is sampled on the falling edge of NCMDSTRB. The STATUS line can be tied
to any of the Status Word Bit inputs to set those bits in the event of a checksum fail. STATUS
is an open output line that will set the selected Status Word Bits for the Status Word
response in the current message. This is one of the great features for this product. The
subsystem does not have to verify the checksum in software to detect the error. The SmaRT
unit automatically does this in hardware and the unit is able to flag the error and set the a
Status Word Bit on the CURRENT Status Word response . This minimizes processor
overhead and reduces response time in notifying the Bus Controller that an error has
occurred.
For 1760 applications, the NVALCHK signal also indicates a valid checksum for the Receive
Command message. NVALCHK is a latched version of the STATUS signal and is updated
only on Receive Commands. It is valid on the falling edge of NCMDSTRB of a Receive
Command and remains stable until the next Receive Command message. A Transmit
Command message will not alter this signal because a Transmit Command does not require
an incoming checksum validation.
CMD WD
T0-15
NEMPTY
VALID
STATUS
NVALCHK
Latched Until Next Receive Command
NCMDSTRB
8.5 µSec
BLOCK TRANSFER LOGIC
The Block Transfer Logic (BTL) may be enabled for both Remote Terminal and Bus
Controller.
The BTL consists of a 32 word memory buffering the subsystem to the main RAM thus
guaranteeing data consistency for both transmit and receive transfers.
All reads and writes to the BTL are identical to read / write to the main RAM. The address
locations are the same. The only difference is that the BTL circuitry will intercept those read
APPLICATION NOTE #108
10
Released 9/98
/ writes and store them in the buffer instead. The user accesses the same locations as if they
would if they were directly accessing the main RAM.
The block transfer logic is enabled with signal NENBTL (pin A7) being active low and is not
applicable to subaddress 00 and 1F (unless McAir is selected) areas of ram. The block
transfer logic may also be configured by writing to certain address locations providing
NENBTL is selected, ie.
0 1 00 02
0 1 00 03
0 1 00 04
0 1 00 05
402h
403h
404h
405h
Disable Read
Disable Read
Enable Read
Enable Read
Disable Write
Enable Write
Disable Write
Enable Write
Reset will enable both Write and Read.
Note: All 257X versions with internal RAM that do not have NENBTL as a dsiscrete input
have it enabled internally.
READ (RECEIVE)
The Read BTL functions similarly to the Write BTL in that the BTL buffers the read activity. A
subsystem read will initially generate a DMA of that entire portion of the subaddress to be
stored in the BTL buffer. The subsystem can then read out the data at its leisure while the
main RAM is free for future updates. Since the entire portion of the subaddress data was
DMA from the RAM, the data read from the BTL buffer is guaranteed contiguous.
The user must read data from the device in a specific sequence starting with the first word
received in the n-1 location and ending with the last word received in location 00 of the
subaddress. The BTL will sense the read from location 00 and reset the sequence ready for
a new access.
1. The first word of a received message will be read first, this will initiate a burst DMA
transfer of a complete message from main memory to the 32 word BTL buffer memory,
during which time the subsystem will be locked out. Data is transferred at the rate of 250
ns per word.
2. The sub system can then read data from the ram at its leisure. The last word to be read
will be the last word received in the message and read from location zero. This will reset
the block transfer logic.
3. If the 1553 DMA transfer to the main RAM becomes active during the burst transfer, the
transfer will complete and then be locked out until the 1553 is complete. However the 32
word BTL buffer memory will be accessible to the subsystem at this time to read out the
data.
4. If the 1553 DMA transfer to the main RAM becomes active before the start of the burst
transfer, the transfer will belocked out until the 1553 is complete. The sub system will be
locked out during this time (main ram being accessed by the 1553 and the 32 word buffer
memory is waiting for the receive message). When the 1553 is complete the burst
transfer will take place and then unlock the subsystem.
APPLICATION NOTE #108
11
Released 9/98
5. Once the burst transfer has commenced it will complete, thus ensuring data consistency.
DMA TRANSFER TIMES
The DMA cycle transfers words from the FIFO to internal RAM at a rate of one word each 1
µSec. The maximum DMA cycle time could possibly occur for a 32 data word transfer if the
RAM is accessed at the beginning of NCMDSTRB Strobe. Maximum subsystem hold-off
time would be 8.5 µSec (NCMDSTRB Signal) + 32 µSec (0.5 µSec per word) for a total of
24.5 µSec.
TRANSMIT COMMAND
The incoming command word is verified for all protocol checks (such as parity and bit count).
The verified command word is placed on the T0-15 bus and the NVCR signal is strobed. It is
at this time that a message can be illegalized.
CMD WD
T0-15
NVCR
NME
500 nSec
600 nSec
Max
Any message can be illegalized by applying an active low on the NME signal within 600
nSec of the rising edge of NVCR at this time. The RT will respond with a Status word having
the Message Error bit set. See Section 1.2.1.1 for implementing the Message Illegalization.
The NCMDSTRB goes low indicating that a completely validated message has been
received. The validated Command Word again appears on the T0-15 bus at this time. The
end of the NCMDSTRB strobe will initiate the DMA cycle to transfer the data words from
internal RAM to the buffer FIFO.
Buffering the outgoing message with a FIFO means that the subsystem is allowed the most
flexibility to access the RAM without contending with 1553 bus traffic. In 1553, data words
are transmitted at a rate of 20 µSec per word or a maximum time of 640 µSec for a 32 word
transfer. Many other systems do not buffer the outgoing data at all. That means that the
RAM is periodically being accessed for data words from the RAM for up to 640 µSeconds.
The SmaRT unit buffers the outgoing data so that the RAM is completely available to the
subsystem after the DMA transfer from RAM occurs. The possibilities of memory contention
is greatly reduced and the contents of the outgoing data will not be affected by subsystem
operations.
The NCMDSTRB pulse is 8.5 µSec long and during this time interval, the bus arbitration
logic is active. If the subsystem has already begun a read/write operation before
NCMDSTRB, the NACK (acknowledge) signal will go low for 500 nSec allowing the
APPLICATION NOTE #108
12
Released 9/98
completion of the read/write command. The read/write operation must be completed within
the remaining 8 µSec. If a read/write operation starts after the NCMDSTRB strobe has
begun, the NACK will not occur and thus hold off the subsystem for the duration of the DMA
cycle from internal RAM.
During NCMDSTRB, the Command Word is loaded into the Command/Status FIFO stack
and the NEMPTY line goes high. The user can utilize this signal as an indication that some
activity has occurred. The Command/Status FIFO stores up to 32 command words for the
subsystem to review. This allows the processor to only response to the 1553 unit when
something has occurred. Constant polling of the 1553 unit is not required. To reduce
processor intervention even further, the Command/Status FIFO will only store commands
that have associated data with it.
MIL-STD-1760 FEATURES
If the 1760 features are enabled (NENCHK line is held low), the checksum word is automatically
generated and transmitted as the last data word. The subsystem processor does not have to
calculate or load the checksum word into RAM. The SmaRT unit automatically does this in hardware
and transmits the correct checksum data word as the last word out. This reduces subsystem
processor overhead significantly.
SIGNALS THAT INDICATE CHECKSUM FAILURE
For 1760 applications, the STATUS line indicates if a message has failed checksum. The STATUS
line will stay high for a Transmit Command word because there is no associated data words received
for checksum validation. STATUS is sampled on the falling edge of NCMDSTRB. The STATUS line
can be tied to any of the Status Word Bit inputs to set those bits in the event of a checksum fail.
STATUS is an open output line that will set the selected Status Word Bits for the Status Word
response in the current message. This is one of the great features for this product. The subsystem
does not have to verify the checksum in software to detect the error. The SmaRT unit automatically
does this in hardware and the unit is able to flag the error and set the a Status Word Bit on the
CURRENT Status Word response . This minimizes processor overhead and reduces response time
in notifying the Bus Controller that an error has occurred.
For 1760 applications, the NVALCHK signal does not change from it's previous state since a Transmit
Command Word has no incoming data words. NVALCHK is a latched version of the STATUS signal
and is updated only on Receive Commands. It is valid on the falling edge of NCMDSTRB of a
Receive Command and remains stable until the next Receive Command message. A Transmit
Command message will not alter this signal because a Transmit Command does not require an
incoming checksum validation.
CMD WD
T0-15
NCMDSTRB
NEMPTY
NVALCHK
* * *
PREVIOUS STATE
* * *
8.5 µSec
APPLICATION NOTE #108
13
Released 9/98
BLOCK TRANSFER LOGIC / DMA TRANSFER TIMES
All reads and writes to the BTL are identical to read / write to the main RAM. The address
locations are the same. The only difference is that the BTL circuitry will intercept those read
/ writes and store them in the buffer instead. The user accesses the same locations as if they
would if they were directly accessing the main RAM.
The block transfer logic may also be configured by writing to certain address locations
providing NENBTL is selected, ie.
0 1 00 02
0 1 00 03
0 1 00 04
0 1 00 05
402h
403h
404h
405h
Disable Read
Disable Read
Enable Read
Enable Read
Disable Write
Enable Write
Disable Write
Enable Write
Reset will enable both Write and Read.
WRITE
The Write BTL Logic basically stores all writes to a particular subaddress in the buffer until
the subsystem has completed the entire subaddress update. When the subsystem has
finished, the BTL will generate a burst DMA from the BTL to main RAM in one contiguous
transfer. This guarantees that the entire subaddress is updated. Until the DMA transfer the
BTL buffer allows the main RAM to be free for updates from the 1553 data bus.
The user must write data to the device in a specific sequence starting with the first word for
transmission in the n-1 location and ending with the last word for transmission in location 00
of the subaddress. The BTL will sense the write to location 00 and initiate the DMA
sequence.
1. Data for one message is written to the 32 word buffer memory at any speed by the
subsystem. The first word for transmission is written first to the n-1 location and the last
word for transmission is written last to the 00 location of the subaddress.
2. The address of the first word is stored in a register / counter within the "block transfer
logic".
3. The last word for transmission is always written to location zero, this will trigger the
transfer of data from the 32 word buffer memory to the main memory. Data is transferred
at the rate of 250 nS per word. A full 32 word transfer will take approximately 8 uS.
4. If the 1553 is quiet the entire message will immediately be transferred in a single burst to
the main memory, the address being generated by the counter within the block transfer
logic. During this transfer the subsystem will be locked out via NACK from any new
updates.
5. If the 1553 DMA transfer to the main RAM becomes active during the burst transfer, the
transfer will complete and then be locked out of any new updates until the 1553 is
complete. However the BTL buffer memory will be accessible to the subsystem at this
time.
6. If the 1553 DMA transfer to the main RAM becomes active before the start of the burst
transfer, the transfer will be locked out (after location zero is written to) until the 1553 is
complete. The sub system will be locked out during this time (main ram being accessed
APPLICATION NOTE #108
14
Released 9/98
by the 1553 and the BTL buffer memory is full). If the BTL memory is not fully loaded, the
subsystem can continue to load the BTL memory until full (write to 00 indicates a full
condition). When the 1553 is complete the burst transfer will take place and then unlock
the subsystem.
7. Once the burst transfer has commenced it will complete, thus ensuring data consistency.
The DMA cycle begins after the rising edge of NCMDSTRB. All requested data words are
placed in an internal buffer FIFO. This is done to double buffer the outgoing data as a
contiguous block and free up the internal RAM as quickly as possible. The DMA cycle
transfers words from internal RAM at a rate of one word each 1 µSec. The maximum DMA
cycle time would occur for a 32 data word transfer or 32 µSec. Maximum subsystem hold-off
time would be 8.5µSec + 32 µSec for a total of 40.5 µSec.
CHANGING THE STATUS WORD BITS
There are four Status word bits that can be altered by the subsystem through simple write
operations. These four bits and addresses are as follows:
SERVREQ
0 0 00 08
008h
BUSY
0 0 00 04
004h
SSFLAG
0 0 00 02
002h
DBCA
0 0 00 01
001h
See Memory Map for further details.
DEVICE STATUS
The status of the device may be determined by reading from location 0 00 01, the status bits
and BTL status will be available on DATA pins 0-7.
DATA0
DATA1
DATA2
DATA3
DATA4
DATA5
DATA6
DATA7
DBCA
SSFLAG
SSBUSY
SERVREQ
BTL WRITE ENABLED
BTL READ ENABLED
OFF-LINE SELF TEST ENABLED
ON-LINE SELF TEST ENABLED
See Memory Map for further details.
BIT REGISTER
With MCAIR (pin F1) disabled, writing data to 0 1 00 13 or 0 1 1F 13 will set the content of
the BIT register. The data may also be read from these locations. This register is
non-resetable. See Memory Map for further details.
APPLICATION NOTE #108
15
Released 9/98
DATA STORAGE AND RETRIEVAL IN RAM
The storage and retrieval of data on RAM is optimized for fast processor accesses. The
data (Transmit or Receive) is stored with the first data word (Word #0) in memory location
#0n and the last data word (Word #n) in location 00. The processor reads the Command
word and extracts the T/R bit, subaddress, and word count bits as a pointer to the proper
memory location. The word count field is used as a down counter variable so that a Do Loop
routine is executed and then branched out at counter = 00. This may be more efficient in
some compilers than an up counter and comparing current loop counter with word count
field on every loop. The following section contains sample software pseudo code for data
handling. See Memory Map for further details.
SAMPLE SOFTWARE CODE
The following section contains sample pseudo-code for programming and operation the
SmaRT unit. The code most resembles Microsoft Quick Basic code (IBM DOS compatible)
for simplicity.
RETRIEVING OR LOADING DATA TO RAM
REM *******************************************************************************************
REM *
REM *
Routines for operation in Remote Terminal (RT) Mode
REM *
REM ********************************************************************************************
REM ********************************************************************************************
REM * Variables
REM * _______
REM *
REM * NCMDEMPTY
0 = EMPTY (NO Command WORDS IN FIFO)
REM *
1 = HAVE COMMAND WORDS IN FIFO
REM *
REM *
This signal is derived from NEMPTY
REM *
on the CT2577.
REM *
REM * MODE
0 = RT MODE
REM *
1 = BC MODE
REM *
REM * CMDWORD = COMMAND WORD READ FROM FIFO
REM *
REM * WORDCNT = LOWER 5 BIT OF COMMAND WORD
REM *
INDICATES HOW MANY DATA WORDS
REM *
REM * DATA() = DATA ARRAY (32 WORDS MAX)
REM *
REM * MEMPOINT = LOWER 11 BITS OF THE COMMAND WORD
REM *
REM * T/R_BIT = BIT #10 OF THE COMMAND WORD
REM *
REM *
APPLICATION NOTE #108
16
Released 9/98
REM *
REM *
REM *******************************************************************************************
REM********************************************************************************************
REM ************ INITIALIZATION ROUTINE
***********************************************
REM *******************************************************************************************
INIT: DEFINT A-Z
OUT 1, 400(h) "WRITE TO THIS ADDRESS TO SET CT2577 INTO RT MODE
INPUT MODE, XX(h) "READ PIN BCNRT FROM THE CT2577
"
0 = RT MODE
"
1 = BC MODE
DIM DATA(32)
"LOCATIONS 1-32 = 32 WORDS
REM ******************************************************************************************
REM ******************************************************************************************
REM ************ DETECT COMMAND ROUTINE ****************************************
REM ******************************************************************************************
DETECT: IF NCMDEMPTY = 1 THEN
CMDWORD = INPUT(OOh) ;READ FROM LOCATION 00
MEMPOINT = CMDWORD & 0000011111111111(b)
T/R_BIT = CMDWORD & 0000010000000000(b)
WORDCNT = CMDWORD & 0000000000011111(b)
MEMPOINT = MEMPOINT - 1
"OFFSET POINTER SO THAT FINAL POSITION
"IS AT LOCATION 00. FOR EXAMPLE, A ONE
"WORD TRANSFER SHOULD BE LOADED IN
"LOCATION 00 OF THAT SUBADDRESS.
END IF
IF WORDCNT = 00000(b) THEN
WORDCNT = 32 "ALL ZEROS IN WORD COUNT FIELD = 32 DATA WORDS
END IF
IF T/R_BIT = 0000000000000000(b) THEN
REDIM DATA() ;CLEARS ARRAY DATA()
; GOT TO ROUTINE TO READ OUT
; THE RECEIVED DATA FROM THE 1553 BUS
GOTO RECEIVE
END IF
IF T/R_BIT = 0000010000000000(b) THEN
REDIM DATA()
;CLEARS ARRAY DATA()
FOR J = 1 TO 32
APPLICATION NOTE #108
17
Released 9/98
DATA(J) = XXXX ;LOAD IN DATA FOR TRANSMIT
NEXT J
GOTO TRANSMIT
END IF
GOTO END
REM ***********************************************************************************************
REM *** ROUTINE TO LOAD DATA INTO RAM FROM PROCESSOR *************************
REM ***********************************************************************************************
TRANSMIT: FOR I = 1 TO WORDCNT
OUTPUT DATA(I), MEMPOINT ; WRITES DATA() INTO LOCATION
; MEMPOINT
MEMPOINT = MEMPOINT - 1
NEXT I
GOTO END
REM
******************************************************************************************************
REM *** ROUTINE TO READ DATA FROM RAM TO PROCESSOR
********************************
REM
******************************************************************************************************
RECEIVE: FOR I = 1 TO WORDCNT
DATA(I) = INPUT(MEMPOINT) ; READS LOCATION MEMPOINT INTO
; DATA() ARRAY
MEMPOINT = MEMPOINT - 1
NEXT I
GOTO END
REM
******************************************************************************************************
REM *** ROUTINE TO SCAN FOR MORE MESSAGES
****************************************
REM
******************************************************************************************************
END:
IF NCMDEMPTY = 1 THEN
GOTO DETECT
ELSE
RETURN
; GO OFF AND DO SOMETHING ELSE
; UNTIL ANOTHER 1553 MESSAGE IS RECEIVED
END IF
APPLICATION NOTE #108
18
Released 9/98
SELF TEST
The self test feature is an internal and external loop back test for additional verification of
functionality. This is in addition to the Remote Terminal Wraparound circuitry. The difference
is that this test is manual and under subsystem control. The subsystem microprocessor
initiates the self test and the subsequent data word pattern. The subsystem then reads back
the wrapped data word and determines if it is correct. The online self test must be done with
the 1553 data bus quiet.
The self test function is enabled or disabled by writing to certain address locations. Reset
will disable self test.
0 1 00 06
0 1 00 07
0 1 00 08
Enable offline self test and set device status bit 6
Enable online self test and set device status bit 7
Disable self test
When self test is enabled the device is set up as both BC and RT. When self test is disabled
the device will revert back to its previous state.
BASIC OPERATION
The basic operation is for the BC to transmit the message "receive one data word" and for
the RT to receive this message.
If the online self test is selected the message will be transmitted onto the 1553 bus via the
transceivers and be received by the RT via transceivers. The RT will not respond with
Status.
If the offline self test is selected the transceivers will be inhibited and the Manchester
encoder output is routed to the Manchester decoder input.
The status of the device may be obtained by reading from 0 0 00 01. Bit 6 is offline self test
enabled. Bit 7 is online self test enabled.
DETAILED OPERATION
1. Enable self test by writing to either 1 00 06 (offline) or 0 1 00 07 (online).
2.
Select required 1553 data bus to be tested by writing to 0 0 00 10 or 0 0 00 18.
3. Write the data word contents required for the self test to the appropriate RAM location ie. For
broadcast message: 2(bcast) 01-1E(subaddress) 00(1 word) or normal receive message: 0(rec)
01-1E(subaddress) 00(1 word).
4. Initiate BC to RT transfer of one data word by writing to address 0 00 00 with a data word content
of 1F or RTaddr 0(rec) 01-1E(subaddress) 01(1 data word). The following automatic sequence is
now initiated:
a) The Command word (data word written to location 0 0 00 00) is processed by the BC protocol,
transferred to the Manchester encoder and transmitted onto the bus (online self test) or to the
Manchester decoder (offline self test).
APPLICATION NOTE #108
19
Released 9/98
b) The self test data word is read from the appropriate RAM location, transferred to the encoder
and transmitted contiguously following the command word.
c) The Command word is received by the Manchester decoder, if valid and with correct RT
address or broadcast is stored in the RT protocol.
d) The data word is received by the decoder and if valid is stored in the 32 word data memory.
e) The RT protocol will validate the message and if successful will write the Command word to
the 32 word Command / Status memory and transfer the data word to the appropriate RAM
location.
5.
As the data word received is written to the same RAM location that it was originally accessed
from, the contents should be altered while the self test is in progress (eg. write 0000). This can be
done immediately after the BC to RT transfer was initiated. There is approx 45 us for the self test
to complete.
6. To ensure that the RAM contents have been altered it is advisable to read the data back from the
RAM.
7. On completion of a successful self test the signal NCMDSTRB will go active low, after which the
data can be read from the RAM and compared with the data used in the self test.
8. In addition the Command word used in the self test may be read from 0 00 00.
9. Disable self test by writing to 1 00 08. The device will revert back to its original state (BC or RT).
APPLICATION NOTE #108
20
Released 9/98
SUMMARY OF OPERATION
Device can be either RT or BC.
1. ADDR = 1 00 06 (Write)
OR
ADDR = 1 00 07 (Write)
Select offline self test.
2. ADDR = 1 00 10 (Write)
OR
ADDR = 1 00 18 (Write)
Select bus 0.
3. ADDR = 2 01-1E 00 (Write) DATA = n
OR
ADDR = 0 01-1E 00 (Write) DATA = n
Write self test data to BCAST location.
4. ADDR = 0 00 00 (Write) DATA = 1F 0 01-1E 01
OR
ADDR = 0 00 00 (Write) DATA = RTAD 0 01-1E 01
Transmit message (Bcast receive 1 word).
5. ADDR = 2 01-1E 00 (Write) DATA = 0
OR
ADDR = 0 01-1E 00 (Write) DATA = 0
Write 0 to self test location.
6. ADDR = 2 01-1E 00 (Read) DATA = 0
OR
ADDR = 0 01-1E 00 (Read) DATA = 0
Read 0 from self test location.
7. ADDR = 2 01-1E 00 (Read) DATA = n
OR
ADDR = 0 01-1E 00 (Read) DATA = n
Read self test data after NCMDSTRB.
8. ADDR = 0 00 00 (Read) DATA = 1F 0 01-1E 01
OR
or ADDR = 0 00 00 (Read) DATA = RTAD 0 01-1E 01
Read command from command memory.
9. ADDR = 1 00 08 (Write)
ADDR = 0 00 01 (Read)
Disable self test.
Read device status:
Bit 6 = Offline self test.
Bit 7 = Online self test
APPLICATION NOTE #108
Select online self test.
Select bus 1.
Write self test data to RECEIVE location.
Transmit message (Receive 1 word).
Write 0 to self test location.
Read 0 from self test location.
Read self test data after NCMDSTRB.
21
Read command from command memory.
Released 9/98
CT2577 /79 RT/BC Device Memory Map Breakdown
The following description is for devices that have internal 3K memory.
ALL 'User' Locations are Read/Writable
BCST (Binary)
T/R
(Binary)
Subaddress (Hex)
Word Count (Hex)
Composite VME Address 16-bit mode (Hex)
Composite VME Address 8-bit mode (Hex) = Lower Byte
Upper Byte = Address +1
Composite MULTIbus Address 16-bit mode (Hex)
FUNCTION
0
0
00
00
000
0000
FFF
W - Command Word (2nd RT-RT Command) (BC)
TRIGGERS BC - BUS ’X’ Operation
R - Received STATUS (FIFO Stack) (BC)
W - Resets ALL Status Bits (RT)
R - RT Received COMMAND (RT)
0
0
00
01
001
0002
FFE
R/W - 1st RT-RT COMMAND (BC)
R/W - Memory Address 002 through 00Fh (BC)
W - Sets STATUS Word Flags as Described below (RT)
R - ALL Status Bits WRITTEN (RT) via Addresses 001--00F plus BURST Control as Follows:
x = Don't Care
Y = STATUS Word Bits Selected via WRITEs to 001 through 00Fh
B = BURST Control Selected via WRITEs to 402 through 405h
xxxx xxxx 00 B B Y Y Y Y
DBC
SSF
BUSY
SR
BTL WRITE ENABLED (TX)
BTL READ ENABLED (RX)
APPLICATION NOTE #108
22
Released 9/98
RT/BC Device Memory Map Code Breakdown Descriptions
RT STATUS WORD Control Sets
0 0 00 01
0 0 00 02
0 0 00 03
0 0 00 04
0 0 00 05
0 0 00 06
0 0 00 07
0 0 00 08
0 0 00 09
0 0 00 0A
0 0 00 0B
0 0 00 0C
0 0 00 0D
0 0 00 0E
0 0 00 0F
001
002
003
004
005
006
007
008
009
00A
00B
00C
00D
00E
00F
0002
0004
0006
0008
000A
000C
000E
0010
0012
0014
0016
0018
001A
001C
001E
FFFE
FFFD
FFFC
FFFB
FFFA
FFF9
FFF8
FFF7
FFF6
FFF5
FFF4
FFF3
FFF2
FFF1
FFF0
DBC
SSFLAG
SSFLAG + DBC
BUSY
BUSY + DBC
BUSY + SSFLAG
BUSY + SSFLAG + DBC
SERVREQ
SERVREQ + DBC
SERVREQ + SSFLAG
SERVREQ + SSFLAG + DBC
SERVREQ + BUSY
SERVREQ + BUSY + DBC
SERVREQ + BUSY + SSFLAG
SERVREQ + BUSY + SSFLAG + DBC
0020
018
FFEF
0040
BC - SELECT BUS 0
FFE7BC - SELECT BUS 1)
BC Control Area
0 0 00 10
010
(18
RT/RX BC/TX Mode Area 00 - SA 00 (0) and BC Control
0 0 00 11
0 0 00 12
0 0 00 13
0 0 00 14
0 0 00 15
0 0 00 16
0 0 00 17
0 0 00 18
(10
0 0 00 19
THROUGH
0 0 00 1F
011
012
013
014
015
016
017
018
010
019
0022
0024
0026
0028
002A
002C
002E
0030
0020
0032
FFEE
FFED
FFEC
FFEB
FFEA
FFE9
FFE8
FFE7
FFEF
FFE6
SYNC WORD
ERROR Register
User
SELECTED TX SHUTDOWN (0000/0001)
OVERRIDE SELECTED TX SHUTDOWN (0000/0001)
User
User
BC - SELECT BUS 1
BC - SELECT BUS 0)
User
01F
003E
FFE0
User
30 RT Receive / BC Transmit Subaddresses - SA 01-1E (1-30)
0 0 01 00
0 0 01 04
0 0 01 1F
020
024
03F
0040
0048
007E
FFDF
FFDB
FFC0
SA1Last Word (Word 01 if WC =1)
Word 01 if WC = 5
Word 01 if WC = 32
0 0 02 00
0 0 02 1F
0 0 03 00
040
05F
060
0080
00BE
00C0
FFBF
FFA0
FF9F
SA2
APPLICATION NOTE #108
SA3
23
Released 9/98
0 0 03 1F
0 0 04 00
0 0 04 1F
0 0 05 00
0 0 05 1F
0 0 06 00
0 0 06 1F
0 0 07 00
0 0 07 1F
0 0 08 00
0 0 08 1F
0 0 09 00
0 0 09 1F
0 0 0A 00
0 0 0A 1F
0 0 0B 00
0 0 0B 1F
0 0 0C 00
0 0 0C 1F
0 0 0D 00
0 0 0D 1F
0 0 0E 00
0 0 0E 1F
0 0 0F 00
0 0 0F 1F
0 0 10 00
0 0 10 1F
0 0 11 00
0 0 11 00
0 0 12 00
0 0 12 1F
0 0 13 00
0 0 13 1F
0 0 14 00
0 0 14 1F
0 0 15 00
0 0 15 1F
0 0 16 00
0 0 16 1F
0 0 17 00
0 0 17 1F
0 0 18 00
0 0 18 1F
0 0 19 00
0 0 19 1F
0 0 1A 00
0 0 1A 1F
0 0 1B 00
0 0 1B 1F
07F
080
09F
0A0
0BF
0C0
0DF
0E0
0FF
100
11F
120
13F
140
15F
160
17F
180
19F
1A0
1BF
1C0
1DF
1E0
1FF
200
21F
220
23F
240
25F
260
27F
280
29F
2A0
2BF
2C0
2DF
2E0
2FF
300
31F
320
33F
340
35F
360
37F
00FE
0100
013E
0140
017E
0180
01BE
01C0
01FE
0200
023E
0240
027E
0280
02BE
02C0
02FE
0300
033E
0340
037E
0380
03BE
03C0
03FE
0400
043E
0440
047E
0480
04BE
04C0
04FE
0500
053E
0540
057E
0580
05BE
05C0
05FE
0600
063E
0640
067E
0680
06BE
06C0
06FE
APPLICATION NOTE #108
FF80
FF7F
FF60
FF5F
FF40
FF3F
FF20
FF1F
FF10
FEFF
FEE0
FEDF
FEC0
FEBF
FEA0
FE9F
FE80
FE7F
FE60
FE5F
FE40
FE3F
FE20
FE1F
FE00
FDFF
FDE0
FDDF
FDC0
FDBF
FDA0
FD9F
FD80
FD7F
FD60
FD5F
FD40
FD3F
FD20
FD1F
FD00
FCFF
FCE0
FCDF
FCC0
FCBF
FCA0
FC9F
FC80
SA4
SA5
SA6
SA7
SA8
SA9
SA10
SA11
SA12
SA13
SA14
SA15
SA16
SA17
SA18
SA19
SA20
SA21
SA22
SA23
SA24
SA25
SA26
SA27
24
Released 9/98
0 0 1C 00
0 0 1C 1F
0 0 1D 00
0 0 1D 1F
0 0 1E 00
0 0 1E 1F
380
39F
3A0
3BF
3C0
3DF
0700
073E
0740
077E
0780
07BE
FC7F
FC60
FC5F
FC40
FC3F
FC20
SA28
SA29
SA30
RT/RX BC/TX Mode Area - SA 1F (31)
0 0 1F 00
THROUGH
0 0 1F 10
0 0 1F 11
0 0 1F 12
0 0 1F 13
0 0 1F 14
0 0 1F 15
0 0 1F 16
THROUGH
0 0 1F 1F
3E0
07C0
FC1F
User
3F0
3F1
3F2
3F3
3F4
3F5
3F6
07E0
07E2
07E4
07E6
07E8
07EA
07EC
FC0F
FC0E
FC0D
FC0C
FC0B
FC0A
FC09
User
SYNC WORD
User
User
SELECTED TX SHUTDOWN (0000/0001)
OVERRIDE SELECTED TX SHUTDOWN (0000/0001)
User
3FF
07FE
FC00
User
FBFF
FBFE
SELECT RT
SELECT BC
RT/BC Control Area
0 1 00 00
0 1 00 01
400
401
0800
0802
RT/BC Block Transfer Logic (BTL) Control and Self Test Control
0 1 00 02
0 1 00 03
0 1 00 04
0 1 00 05
0 1 00 06
0 1 00 06
0 1 00 06
0 1 00 06
THROUGH
0 1 00 0F
402
403
404
405
406
407
408
409
0804
0806
0808
080A
080C
080E
0810
0812
FBFD
FBFC
FBFB
FBFA
FBF9
FBF8
FBF7
FBF6
RX BTL OFF / TX BTL OFF
RX BTL OFF / TX BTL ON
RX BTL ON / TX BTL OFF
RX BTL ON / TX BTL ON
OFF- LINE Self Test
ON-LINE Self Test
DISABLE Self Test
User
40F
081E
FBF0
User
RT/TX BC/RX Mode Area - SA 00 (0)
0 1 00 10
0 1 00 11
0 1 00 12
0 1 00 13
0 1 00 14
THROUGH
0 1 00 1F
410
411
412
413
414
0820
0822
0824
0826
0828
FBEF
FBDF
FBCF
FBBF
FBAF
VECTOR WORD
User
LAST COMMAND
BIT WORD
User
41F
083E
FBE0
User
APPLICATION NOTE #108
25
Released 9/98
30 RT Transmit / BC Receive Subaddresses - SA 01-1E (1-30)
0 1 01 00
0 1 01 04
0 1 01 1F
420
424
43F
0840
0848
087E
FBDF
FBDB
FBC0
SA1 Last Word (Word 01 if WC =1)
SA1 Word 01 if WC = 5
SA1 Word 01 if WC = 32
0 1 02 00
0 1 02 1F
0 1 03 00
0 1 03 1F
0 1 04 00
0 1 04 1F
0 1 05 00
0 1 05 1F
0 1 06 00
0 1 06 1F
0 1 07 00
0 1 07 1F
0 1 08 00
0 1 08 1F
0 1 09 00
0 1 09 1F
0 1 0A 00
0 1 0A 1F
0 1 0B 00
0 1 0B 1F
0 1 0C 00
0 1 0C 1F
0 1 0D 00
0 1 0D 1F
0 1 0E 00
0 1 0E 1F
0 1 0F 00
0 1 0F 1F
0 1 10 00
0 1 10 1F
0 1 11 00
0 1 11 00
0 1 12 00
0 1 12 1F
0 1 13 00
0 1 13 1F
0 1 14 00
0 1 14 1F
0 1 15 00
0 1 15 1F
0 1 16 00
0 1 16 1F
0 1 17 00
440
45F
460
47F
480
49F
4A0
4BF
4C0
4DF
4E0
4FF
500
51F
520
53F
540
55F
560
57F
580
59F
5A0
5BF
5C0
5DF
5E0
5FF
600
61F
620
63F
640
65F
660
67F
680
69F
6A0
6BF
6C0
6DF
6E0
0880
08BE
08C0
08FE
0900
093E
0940
097E
0980
09BE
09C0
09FE
0A00
0A3E
0A40
0A7E
0A80
0ABE
0AC0
0AFE
0B00
0B3E
0B40
0B7E
0B80
0BBE
0BC0
0BFE
0C00
0C3E
0C40
0C7E
0C80
0CBE
0CC0
0CFE
0D00
0D3E
0040
0D7E
0D80
0DBE
0DC0
FBBF
FBA0
FB9F
FB80
FB7F
FB60
FB5F
FB40
FB3F
FB20
FB1F
FB00
FAFF
FAE0
FADF
FAC0
FABF
FAA0
FA9F
FA80
FA7F
FA60
FA5F
FA40
FA3F
FA20
FA1F
FA00
F9FF
F9E0
F9DF
F9C0
F9BF
F9A0
F99F
F980
F97F
F960
F95F
F940
F93F
F920
F91F
SA2
APPLICATION NOTE #108
SA3
SA4
SA5
SA6
SA7
SA8
SA9
SA10
SA11
SA12
SA13
SA14
SA15
SA16
SA17
SA18
SA19
SA20
SA21
SA22
SA23
26
Released 9/98
0 1 17 1F
0 1 18 00
0 1 18 1F
0 1 19 00
0 1 19 1F
0 1 1A 00
0 1 1A 1F
0 1 1B 00
0 1 1B 1F
0 1 1C 00
0 1 1C 1F
0 1 1D 00
0 1 1D 1F
0 1 1E 00
0 1 1E 1F
6FF
700
71F
720
73F
740
75F
760
77F
780
79F
7A0
7BF
7C0
7DF
0DFE
0E00
0E3E
0E40
0E7E
0E80
0EBE
0EC0
0EFE
0F00
0F3E
0F40
0F7E
0F80
0FBE
F900
F8FF
F8E0
F8DF
F8C0
F8BF
F8A0
F89F
F880
F87F
F860
F85F
F840
F83F
F820
SA24
SA25
SA26
SA27
SA28
SA29
SA30
RT/ TX BC/RX Mode Area - SA 1F (31)
0 1 1F 00
THROUGH
0 1 1F 0F
0 1 1F 10
0 1 1F 11
0 1 1F 12
0 1 1F 13
0 1 1F 14
THROUGH
0 1 1F 1F
7E0
0FC0
F81F
7EF
7F0
7F1
7F2
7F3
7F4
0FDE
0FE0
0FE2
0FE4
0FE6
0FE8
F810
F80F
F80E
F80D
F80C
F80B
VECTOR WORD
User
LAST COMMAND
BIT WORD
User
7FF
0FFE
F800
User
Broadcast RT/RX BC/TX Mode Area - SA 00 (0)
1 0 00 00
THROUGH
1 0 00 10
1 0 00 11
1 0 00 12
1 0 00 13
1 0 00 14
1 0 00 15
1 0 00 16
THROUGH
1 0 00 1F
800
1000
F7FF
User
810
811
812
813
814
815
816
1020
1022
1024
1036
1028
102A
102C
F7EF
F7EE
F7ED
F7EC
F7EB
F7EA
F7E9
User
SYNC WORD
User
User
SELECTED TX SHUTDOWN (0000/0001)
OVERRIDE SELECTED TX SHUTDOWN (0000/0001)
User
81F
103E
F7E0
User
30 Broadcast RT Receive / BC Transmit Subaddresses - SA 01-1E (1-30)
1 0 01 00
1 0 01 04
1 0 01 1F
1 0 02 00
1 0 02 1F
820
824
83F
840
85F
1040
1048
107E
1080
10BE
APPLICATION NOTE #108
F7DF
F7DB
F7C0
F7BF
F7A0
SA1 Last Word (Word 01 if WC =1)
SA1 Word 01 if WC = 5
SA1 Word 01 if WC = 32
SA2
27
Released 9/98
1 0 03 00
1 0 03 1F
1 0 04 00
1 0 04 1F
1 0 05 00
1 0 05 1F
1 0 06 00
1 0 06 1F
1 0 07 00
1 0 07 1F
1 0 08 00
1 0 08 1F
1 0 09 00
1 0 09 1F
1 0 0A 00
1 0 0A 1F
1 0 0B 00
1 0 0B 1F
1 0 0C 00
1 0 0C 1F
1 0 0D 00
1 0 0D 1F
1 0 0E 00
1 0 0E 1F
1 0 0F 00
1 0 0F 1F
1 0 10 00
1 0 10 1F
1 0 11 00
1 0 11 00
1 0 12 00
1 0 12 1F
1 0 13 00
1 0 13 1F
1 0 14 00
1 0 14 1F
1 0 15 00
1 0 15 1F
1 0 16 00
1 0 16 1F
1 0 17 00
1 0 17 1F
1 0 18 00
1 0 18 1F
1 0 19 00
1 0 19 1F
1 0 1A 00
1 0 1A 1F
1 0 1B 00
860
87F
880
89F
8A0
8BF
8C0
8DF
8E0
8FF
900
91F
920
93F
940
95F
960
97F
980
99F
9A0
9BF
9C0
9DF
9E0
9FF
A00
A1F
A20
A3F
A40
A5F
A60
A7F
A80
A9F
AA0
ABF
AC0
ADF
AE0
AFF
B00
B1F
B20
B3F
B40
B5F
B60
10C0
10FE
1100
113E
1140
117E
1180
11BE
11C0
11FE
1200
123E
1240
127E
1280
12BE
12C0
12FE
1300
133E
1340
137E
1380
13BE
13C0
133E
1400
143E
1440
147E
1480
14BE
14C0
14FE
1500
153E
1540
157E
1580
15BE
15C0
15FE
1600
163E
1640
167E
1680
16BE
16C0
APPLICATION NOTE #108
F79F
F780
F77F
F760
F75F
F740
F73F
F720
F71F
F700
F6FF
F6E0
F6DF
F6C0
F6BF
F6A0
F69F
F680
F67F
F660
F65F
F640
F63F
F620
F61F
F600
F5FF
F5E0
F5DF
F5C0
F5BF
F5A0
F59F
F580
F57F
F560
F55F
F540
F53F
F520
F51F
F500
F4FF
F4E0
F4DF
F4C0
F4BF
F4A0
F49F
SA3
SA4
SA5
SA6
SA7
SA8
SA9
SA10
SA11
SA12
SA13
SA14
SA15
SA16
SA17
SA18
SA19
SA20
SA21
SA22
SA23
SA24
SA25
SA26
SA27
28
Released 9/98
1 0 1B 1F
1 0 1C 00
1 0 1C 1F
1 0 1D 00
1 0 1D 1F
1 0 1E 00
1 0 1E 1F
B7F
B80
B9F
BA0
BBF
BC0
BDF
16FE
1700
173E
1740
177E
1780
17BE
F480
F47F
F460
F45F
F440
F43F
F420
SA28
SA29
SA30
Broadcast RT/RX BC/TX Mode Area 1F - SA 1F (31)
1 0 1F 00
THROUGH
1 0 1F 10
1 0 1F 11
1 0 1F 12
1 0 1F 13
1 0 1F 14
1 0 1F 15
1 0 1F 16
THROUGH
1 0 1F 1F
BE0
17C0
F41F
User
BF0
BF1
BF2
BF3
BF4
BF5
BF6
17E0
17E2
17E4
17E6
17E8
17EA
17EC
F40F
F40E
F40D
F40C
F40B
F40A
F409
User
SYNC WORD
User
User
SELECTED TX SHUTDOWN (0000/0001)
OVERRIDE SELECTED TX SHUTDOWN (0000/0001)
User
BFF
17FE
F400
User
APPLICATION NOTE #108
29
Released 9/98
CT2577 / 79 Part Ordering
Information
APPLICATION NOTE #108
30
Released 9/98
CT2577 - Mil-Std 1553 / 1760 Bus Controller/Remote
Terminal
CT2577- XX- YY- ZZ
P 1 1 9 = 119 Pin PGA
F 8 4 = 84 Pin Quad Flatpack
QM
= Full Mil 883C Screened Part (-550C to +1250C)
XT
= Extended Temperature Range (-550C to +1250C)
I N
= Industrial Temperature Range (-400C to +850C)
CG
= Commercial Grade (00C to +700C)
XX
= Function Selection
0 = Memory Enabled (T0-T15 Bus)
1 = Memory Enabled (T0-T10 Bus)
0 = No Stores Pinout
1 = Stores Pinout
APPLICATION NOTE #108
31
Released 9/98
CT2578 - Mil-Std 1553 / 1760 Bus Remote Terminal Only
CT2578- XX- YY- ZZ
P 1 1 9 = 119 Pin PGA
F 8 4 = 84 Pin Quad Flatpack
QM
= Full Mil 883C Screened Part (-550C to +1250C)
XT
= Extended Temperature Range (-550C to +1250C)
I N
= Industrial Temperature Range (-400C to +850C)
CG
= Commercial Grade (00C to +700C)
XX
= Function Selection
0 = Memory Enabled (T0-T15 Bus)
1 = Memory Enabled (T0-T10 Bus)
2 = No Memory Enabled (DMA)
0 = No Stores Pinout
1 = Stores Pinout
APPLICATION NOTE #108
32
Released 9/98
CT2579 - McAir Bus Remote Controller/Remote Terminal
CT2579- XX- YY- ZZ
P 1 1 9 = 119 Pin PGA
F 8 4 = 84 Pin Quad Flatpack
QM
= Full Mil 883C Screened Part (-550C to +1250C)
XT
= Extended Temperature Range (-550C to +1250C)
I N
= Industrial Temperature Range (-400C to +850C)
CG
= Commercial Grade (00C to +700C)
XX
= Function Selection
0 = Memory Enabled (T0-T15 Bus)
1 = Memory Enabled (T0-T10 Bus)
0 = No Stores Pinout
1 = Stores Pinout
APPLICATION NOTE #108
33
Released 9/98
CT2580 - McAir Bus Remote Terminal Only
CT2580- XX- YY- ZZ
P 1 1 9 = 119 Pin PGA
F 8 4 = 84 Pin Quad Flatpack
QM
= Full Mil 883C Screened Part (-550C to +1250C)
XT
= Extended Temperature Range (-550C to +1250C)
I N
= Industrial Temperature Range (-400C to +850C)
CG
= Commercial Grade (00C to +700C)
XX
= Function Selection
0 = Memory Enabled (T0-T15 Bus)
1 = Memory Enabled (T0-T10 Bus)
0 = No Stores Pinout
1 = Stores Pinout
APPLICATION NOTE #108
34
Released 9/98
CT2577 / 79 Pinouts
APPLICATION NOTE #108
35
Released 9/98
CT2577-01-xx-F84 Pinouts – 84 Pin Quad Flatpack
Pin #
1
Description
ADIN 11
Pin #
43
Description
NCMDSTRB
2
ADIN 10
44
NEMPTY
3
ADIN 09
45
DATA 00
4
BCNRT
46
DATA 01
5
NSYNC
47
NSSFLAG
6
ADIN 08
48
UB
7
Not Connected
49
NBIT16
8
Not Connected
50
Not Connected
9
ADIN 07
51
DATA 02
10
ADIN 06
52
Not Connected
11
MCDET
53
DATA 03
12
NVCR
54
DATA 04
13
BCST
55
DATA 05
14
NTF
56
WRAPEN
15
ADIN 05
57
DATA 06
16
ADIN 04
58
T 00
17
NME
59
DATA 07
18
ADDR E
60
DATA 08
19
NDBC
61
T 01
20
EOT
62
T 02
21
ADDR D
63
DATA 09
22
ADDR C
64
DATA 10
23
ADDR B
65
DATA 11
24
NWR
66
T 03
25
ADDR A
67
T 04
26
NRD
68
T 05
27
NACK
69
DATA 12
28
ADDR P
70
T 06
29
DATA (Bus 0 )
71
DATA 13
30
NDATA (Bus 0 )
72
DATA 14
31
NSTSTRB
73
T 07
32
NCARDEN
74
DATA (Bus 1)
33
ERROR
75
NDATA (Bus 1 )
34
VDD1
76
NFULL
35
VSS1
77
DATA 15
36
C16MHZ
78
VDD2
37
LA
79
VSS2
38
ADIN 03
80
NILLCMD
39
ADIN 02
81
T 08
40
ADIN 01
82
T 09
41
NRES/NRCL
83
T 10
42
ADIN 00
84
VME(/MULTI)
APPLICATION NOTE #108
36
Released 9/98
CT2577-11-xx-F84 Pinouts – 84 Pin Quad Flatpack
Pin #
1
Description
ADIN 11
Pin #
43
Description
NCMDSTRB
2
ADIN 10
44
NEMPTY
3
ADIN 09
45
DATA 00
4
BCNRT
46
DATA 01
5
NSYNC
47
NSSFLAG
6
ADIN 08
48
UB
7
NVALCHK (1760)
49
NBIT16
8
STATUS (1760)
50
NHDR (1760)
9
ADIN 07
51
DATA 02
10
ADIN 06
52
STREL (1760)
11
NENCHK (1760)
53
DATA 03
12
NVCR
54
DATA 04
13
BCST
55
DATA 05
14
NTF
56
WRAPEN
15
ADIN 05
57
DATA 06
16
ADIN 04
58
T 00
17
NME
59
DATA 07
18
ADDR E
60
DATA 08
19
NDBC
61
T 01
20
EOT
62
T 02
21
ADDR D
63
DATA 09
22
ADDR C
64
DATA 10
23
ADDR B
65
DATA 11
24
NWR
66
T 03
25
ADDR A
67
T 04
26
NRD
68
T 05
27
NACK
69
DATA 12
28
ADDR P
70
T 06
29
DATA (Bus 0)
71
DATA 13
30
NDATA (Bus 0)
72
DATA 14
31
NSTSTRB
73
T 07
32
NCARDEN
74
DATA (Bus 1)
33
ERROR
75
NDATA (Bus 1)
34
VDD1
76
NFULL
35
VSS1
77
DATA 15
36
C16MHZ
78
VDD2
37
LA
79
VSS2
38
ADIN 03
80
NILLCMD
39
ADIN 02
81
T 08
40
ADIN 01
82
T 09
41
NRES/NRCL
83
T 10
42
ADIN 00
84
VME(/MULTI)
APPLICATION NOTE #108
37
Released 9/98
CT2579-01-xx-F84 Pinouts – 84 Pin Quad Flatpack
Pin #
1
Description
ADIN 11
Pin #
43
Description
NCMDSTRB
2
ADIN 10
44
NEMPTY
3
ADIN 09
45
DATA 00
4
BCNRT
46
DATA 01
5
NSYNC
47
NSSFLAG
6
ADIN 08
48
UB
7
Not Connected
49
NBIT16
8
Not Connected
50
Not Connected
9
ADIN 07
51
DATA 02
10
ADIN 06
52
Not Connected
11
MCDET
53
DATA 03
12
NVCR
54
DATA 04
13
BCST
55
DATA 05
14
NTF
56
WRAPEN
15
ADIN 05
57
DATA 06
16
ADIN 04
58
T 00
17
NME
59
DATA 07
18
ADDR E
60
DATA 08
19
NDBC
61
T 01
20
EOT
62
T 02
21
ADDR D
63
DATA 09
22
ADDR C
64
DATA 10
23
ADDR B
65
DATA 11
24
NWR
66
T 03
25
ADDR A
67
T 04
26
NRD
68
T 05
27
NACK
69
DATA 12
28
ADDR P
70
T 06
29
DATA (Bus 0)
71
DATA 13
30
NDATA (Bus 0)
72
DATA 14
31
NSTSTRB
73
T 07
32
NCARDEN
74
DATA (Bus 1)
33
ERROR
75
NDATA (Bus 1)
34
VDD1
76
NFULL
35
VSS1
77
DATA 15
36
C16MHZ
78
VDD2
37
LA
79
VSS2
38
ADIN 03
80
NILLCMD
39
ADIN 02
81
T 08
40
ADIN 01
82
T 09
41
NRES/NRCL
83
T 10
42
ADIN 00
84
VME(/MULTI)
APPLICATION NOTE #108
38
Released 9/98
CT2579-11-xx-F84 Pinouts – 84 Pin Quad Flatpack
Pin #
1
Description
ADIN 11
Pin #
43
Description
NCMDSTRB
2
ADIN 10
44
NEMPTY
3
ADIN 09
45
DATA 00
4
BCNRT
46
DATA 01
5
NSYNC
47
NSSFLAG
6
ADIN 08
48
UB
7
NVALCHK (1760)
49
NBIT16
8
STATUS (1760)
50
NHDR (1760)
9
ADIN 07
51
DATA 02
10
ADIN 06
52
STREL (1760)
11
NENCHK (1760)
53
DATA 03
12
NVCR
54
DATA 04
13
BCST
55
DATA 05
14
NTF
56
WRAPEN
15
ADIN
57
DATA 06
16
ADIN
58
T 00
17
NME
59
DATA 07
18
ADDR E
60
DATA 08
19
NDBC
61
T 01
20
EOT
62
T 02
21
ADDR D
63
DATA 09
22
ADDR C
64
DATA 10
23
ADDR B
65
DATA 11
24
NWR
66
T 03
25
ADDR A
67
T 04
26
NRD
68
T 05
27
NACK
69
DATA 12
28
ADDR P
70
T 06
29
DATA (Bus 0)
71
DATA 13
30
NDATA (Bus 0)
72
DATA 14
31
NSTSTRB
73
T 07
32
NCARDEN
74
DATA (Bus 1)
33
ERROR
75
NDATA (Bus 1)
34
VDD1
76
NFULL
35
VSS1
77
DATA 15
36
C16MHZ
78
VDD2
37
LA
79
VSS2
38
ADIN
80
NILLCMD
39
ADIN
81
T 08
40
ADIN
82
T 09
41
NRES/NRCL
83
T 10
42
ADIN 00
84
VME(/MULTI)
APPLICATION NOTE #108
39
Released 9/98
CT2577-10-xx-P119 Pinouts – 119 Pin Grid Array
Pin #
A1
Description
VME
Pin #
D3
Description
T 13
Pin #
L1
Description
ADIN 4
A2
T 11
D11
T2
L2
NME
A3
T9
D12
DATA 7
L3
EOT
A4
T8
D13
DATA 6
L4
ADDR B
A5
N/C
E1
NSYNC
L5
NACK
A6
N/C
E2
BCNRT
L6
NDATA 0 (BUS)
A7
NENBTL
E3
T 15
L7
VDD
A8
DATA 15
E11
T0
L8
NINHST
A9
DATA 1(BUS)
E12
WRAPEN
L9
ADIN 3
A10
T7
E13
DATA 5
L10
ADIN 0
A11
T6
F1
MCAIR
L11
NCMDSTRB
A12
DATA 12
F2
N/C
L12
NDBCA
A13
T3
F3
ADIN 8
L13
NTXINH 1
B1
ADIN 11
F11
DATA 4
M1
SELEN 0
B2
T 12
F12
NSR
M2
NDBC
B3
N/C
F13
DATA 3
M3
ADDR C
B4
N/C
G1
NVALCHK
M4
NRD
B5
N/C
G2
ADIN 7
M5
N/C
B6
N/C
G3
STATUS
M6
NSTSTRB
B7
VSS
G11
DATA 2
M7
VSS
B8
NFULL
G12
STREL
M8
INHMC
B9
N/C
G13
NHDR
M9
LA
B10
DATA 13
H1
ADIN 6
M10
ADIN 2
B11
T4
H2
NENCHK
M11
NRES
B12
DATA 10
H3
MCDET
M12
N/C
B13
DATA 9
H11
NBUSY
M13
NTXINH 0
C1
T 14
H12
N/C
N1
ADDR D
C2
INITWD
H13
NBIT16
N2
NWR
C4
T 10
J1
WATCHDOG
N3
ADDR A
C5
N/C
J2
NVCR
N4
ADDR P
C6
NILLCMD
J3
NTF
N5
DATA 0(BUS)
C7
VDD
J11
DATA 0
N6
NCARDEN
C8
NDATA 1(BUS)
J12
NSSFLAG
N7
ERROR
C9
DATA 14
J13
UB
N8
N/C
C10
T5
K1
BCST
N9
C16MHZ
C11
DATA 11
K2
ADIN 5
N10
NDATA
C12
T1
K3
ADDR E
N11
ADIN 1
C13
DATA 8
K11
NNEWBUS
N12
N/C
D1
ADIN 9
K12
SELEN 1
N13
NEMPTY
D2
ADIN 10
K13
DATA 1
APPLICATION NOTE #108
40
Released 9/98
CT2579-10-xx-P119 Pinouts – 119 Pin Grid Array
Pin #
A1
Description
VME
Pin #
D3
Description
T 13
Pin #
L1
Description
ADIN 4
A2
T 11
D11
T2
L2
NME
A3
T9
D12
DATA 7
L3
EOT
A4
T8
D13
DATA 6
L4
ADDR B
A5
N/C
E1
NSYNC
L5
NACK
A6
N/C
E2
BCNRT
L6
NDATA 0 (BUS)
A7
NENBTL
E3
T 15
L7
VDD
A8
DATA 15
E11
T0
L8
NINHST
A9
DATA 1(BUS)
E12
WRAPEN
L9
ADIN 3
A10
T7
E13
DATA 5
L10
ADIN 0
A11
T6
F1
MCAIR
L11
NCMDSTRB
A12
DATA 12
F2
N/C
L12
NDBCA
A13
T3
F3
ADIN 8
L13
NTXINH 1
B1
ADIN 11
F11
DATA 4
M1
SELEN 0
B2
T 12
F12
NSR
M2
NDBC
B3
N/C
F13
DATA 3
M3
ADDR C
B4
N/C
G1
NVALCHK
M4
NRD
B5
N/C
G2
ADIN 7
M5
N/C
B6
N/C
G3
STATUS
M6
NSTSTRB
B7
VSS
G11
DATA 2
M7
VSS
B8
NFULL
G12
STREL
M8
INHMC
B9
N/C
G13
NHDR
M9
LA
B10
DATA 13
H1
ADIN 6
M10
ADIN 2
B11
T4
H2
NENCHK
M11
NRES
B12
DATA 10
H3
MCDET
M12
N/C
B13
DATA 9
H11
NBUSY
M13
NTXINH 0
C1
T 14
H12
N/C
N1
ADDR D
C2
INITWD
H13
NBIT16
N2
NWR
C4
T 10
J1
WATCHDOG
N3
ADDR A
C5
N/C
J2
NVCR
N4
ADDR P
C6
NILLCMD
J3
NTF
N5
DATA 0(BUS)
C7
VDD
J11
DATA 0
N6
NCARDEN
C8
NDATA 1(BUS)
J12
NSSFLAG
N7
ERROR
C9
DATA 14
J13
UB
N8
N/C
C10
T5
K1
BCST
N9
C16MHZ
C11
DATA 11
K2
ADIN 5
N10
NDATA
C12
T1
K3
ADDR E
N11
ADIN 1
C13
DATA 8
K11
NNEWBUS
N12
N/C
D1
ADIN 9
K12
SELEN 1
N13
NEMPTY
D2
ADIN 10
K13
DATA 1
APPLICATION NOTE #108
41
Released 9/98