DALLAS DS1221

DS1221
Nonvolatile Controller x 4 Chip
www.dalsemi.com
NOT RECOMMENDED FOR NEW DESIGNS, SEE DS1321 DATASHEET INSTEAD.
FEATURES
PIN ASSIGNMENT
Converts CMOS RAMs into nonvolatile
memories
Data is automatically protected during power loss
2-to-4 decoder provides for up to 4 CMOS
RAMs
Provides for redundant batteries
Test battery condition on power-up
Full ±10% operating range
Unauthorized access can be prevented with
optional security feature
16-pin 0.3-inch DIP saves PC board space
Optional 16-pin SOIC surface mount package
Optional industrial temperature range of
-40°C to +85°C available
VCCO
1
16
VCCI
VBAT1
2
15
VBAT2
*RST
3
14
CE
A
4
13
CE0
B
5
12
CE1
*RD
6
11
CE2
*WE
7
10
CE3
GND
8
9
*D/Q
DS1221 16-Pin DIP (300-mil)
See Mech. Drawings Section
PIN DESCRIPTION
VCCO
1
16
VCCI
A, B
VBAT1
2
15
VBAT2
*RST
3
14
CE
A
4
13
CE0
B
5
12
CE1
*RD
6
11
CE2
*WE
7
10
CE3
GND
8
9
*D/Q
CE
CE0 - CE3
VBAT1
VBAT2
* RST
VCCI
VCCO
* RD
* WE
*D/Q
- Address Inputs
- Chip Enable Input
- Chip Enable Outputs
- + Battery 1
- + Battery 2
- Reset
- +5V Supply
- RAM Supply
- Read Inpu
- Write Input
- Data Input/Output
DS1221 16-Pin SOIC (300-mil)
See Mech. Drawings Section
*Used with optional security circuit only and must be connected to ground in all other cases.
DESCRIPTION
The DS1221 Nonvolatile Controller x 4 Chip is a CMOS circuit which solves the application problem of
converting CMOS RAMs into nonvolatile memories. Incoming power is monitored for an out-oftolerance condition. When such a condition is detected, the chip enable outputs are inhibited to
accomplish write protection and the battery is switched on to supply RAMs with uninterrupted power. An
optional security code prevents unauthorized users from obtaining access to the memory space. The
nonvolatile controller/decoder circuitry uses a low-leakage CMOS process which affords precise voltage
detection at extremely low battery consumption. By combining the DS1221 with up to four CMOS
memories and lithium batteries, nonvolatile operation can be achieved.
1 of 8
111899
DS1221
CONTROLLER /DECODER OPERATION
The DS1221 nonvolatile controller performs six circuit functions required to decode and battery-backup a
bank of up to four CMOS RAMs. First, a 2-to-4 decoder provides selection of one of four RAMs (see
Figure 1). Second, a switch is provided to direct power from the battery or VCCI supply, depending on
which is greater, to the VCCO pin. This switch has a voltage drop of less than 0.2V. The third function
which the nonvolatile controller provides is power-fail detection. The DS1221 constantly monitors the
VCCI supply. When VCCI falls below 4.5 volts, a precision comparator detects the condition and inhibits
the RAM chip enables ( CE0 through CE3 ). The fourth function of write protection is accomplished by
holding all chip enable outputs ( CE0 through CE3 ) to within 0.2 volts of VCCI or battery supply. If the
Chip Enable Input ( CE ) is low at the time power-fail detection occurs, the chip enable outputs are kept in
their present state until CE is driven high. The delay of write protection until the current memory cycle is
completed prevents the corruption of data. Power failure detection occurs in the range of 4.5 to 4.25 volts.
During nominal supply conditions the chip enable outputs follow the logic of a 2-to-4 decoder. The fifth
function the DS1221 performs is to check battery status to warn of potential data loss. Each time that VCCI
power is restored the battery voltage is checked with a precision comparator. If the connected battery
voltage is less than 2 volts, the second memory cycle is inhibited. Battery status can, therefore, be
determined by performing a read cycle after power-up to any location in memory, verifying that memory
location content. A subsequent write cycle can then be executed to the same memory location, altering the
data. If the next read cycle fails to verify the written data, the contents of the memories are questionable.
The sixth function of the nonvolatile controller provides for battery redundancy. In many applications,
data integrity is paramount. In these applications it is often desirable to use two batteries to ensure
reliability. The DS1221 provides an internal isolation switch which provides for connection of two
batteries. During battery back-up operation the battery with the highest voltage is selected for use. If one
battery should fail, the other will automatically take over. The switch between batteries is transparent to
the user. A battery status warning will occur if both batteries are less than 2.0 volts. If only one battery is
used, the second battery input must be grounded. Figure 2 illustrates the connections required for the
DS1221 in a typical application.
NONVOLATILE CONTROLLER/DECODER Figure 1
VCCI
>=4.5
<4.25
>=4.5
>=4.5
>=4.5
>=4.5
H = High Level
L = Low Level
X = Irrelevant
CE
H
X
L
L
L
L
INPUTS
B
X
X
L
L
H
H
OUTPUTS
A
X
X
L
H
L
H
2 of 8
CE0
CE1
CE2
CE3
H
H
L
H
H
H
H
H
H
L
H
H
H
H
H
H
L
H
H
H
H
H
H
L
DS1221
TYPICAL APPLICATION Figure 2
SECURITY SEQUENCE Figure 3
OUTPUT LOAD Figure 4
3 of 8
DS1221
ABSOLUTE MAXIMUM RATINGS*
Voltage on Any Pin Relative to Ground
Operating Temperature
Storage Temperature
Soldering Temperature
Short Circuit Output Current
*
-0.3V to +7.0V
0°C to 70°C
-55°C to +125°C
260°C for 10 seconds
20 mA
This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
RECOMMENDED DC OPERATING CONDITIONS
PARAMETER
Supply Voltage
Logic 1 Input
Logic 0 Input
Battery Input
SYMBOL
VCCI
VIH
VIL
VBAT1,
VBAT2
MIN
4.5
2.2
-0.3
2.0
DC ELECTRICAL CHARACTERISTICS
MIN
TYP
5.0
(0°C to 70°C)
MAX
5.5
VCC+0.3
+0.8
4.0
UNITS
V
V
V
V
NOTES
1
1
1
1, 2
(0°C to 70°C; VCC = 4.5 to 5.5V)
PARAMETER
Supply Current
Supply Voltage
Supply Current
Input Leakage
Output Leakage
CE0 - CE3 , DQ
Output @ 2.4V
CE0 - CE3 , DQ
Output @ 0.4V
VCC Trip Point
SYMBOL
ICCI
VCCO
ICCO1
IIL
ILO
IOH
TYP
VCCTP
4.25
4.37
PARAMETER
CE0 - CE3 Output
SYMBOL
VOHL
MIN
TYP
MAX
5
UNITS
mA
V
mA
µA
µA
mA
NOTES
3
1
4, 10
4.0
mA
5
4.50
V
1
VCC-0.2
80
+1.0
+1.0
-1.0
-1.0
-1.0
IOL
5
(0°C to 70°C; VCC < 4.25V)
VBAT1 or VBAT2
Battery Current
Battery Backup Current
@ VCCO = VBAT - 0.5V
MAX
UNITS
V
NOTES
IBAT
0.1
µA
3
ICCO2
100
µA
6, 7, 10
VCC-0.2
VBAT-0.2
4 of 8
DS1221
CAPACITANCE
PARAMETER
Input Capacitance
Output Capacitance
(tA = 25°C)
SYMBOL
CIN
COUT
MIN
AC ELECTRICAL CHARACTERISTICS
PARAMETER
CE Propagation Delay
CE High to Power-Fail
Address Setup
SYMBOL
tPD
tPF
tAS
TYP
MAX
5
7
UNITS
pF
pF
NOTES
(0°C to 70°C; VCC = 4.5 to 5.5V)
MIN
5
TYP
15
MAX
25
0
20
UNITS
ns
ns
ns
NOTES
5
9
(0°C to 70°C; VCC < 4.5V)
PARAMETER
Recovery at Power-Up
VCC Slew Rate 4.5 - 4.25V
VCC Slew Rate 4.25 - 3V
VCC Slew Rate 4.25 - 4.5V
CE Pulse Width
SYMBOL
tREC
tF
tFB
tR
tCE
MIN
2
300
10
0
TYP
5
MAX
10
1.5
UNITS
ms
µs
µs
µs
µs
NOTES
7, 8
NOTES:
1. All voltages are referenced to ground.
2. Only one battery input is required.
3. Measured with VCCO and CE0 - CE3 open.
4. ICCO1 is the maximum average load which the DS1221 can supply to the memories.
5. Measured with a load as shown in Figure 4.
6. ICCO2 is the maximum average load current which the DS1221 can supply to the memories in the
battery back-up mode.
7. Chip enable outputs CE0 - CE3 can only sustain leakage current in the battery back-up mode.
8. tCE max. must be met to ensure data integrity on power loss.
9. tAS is only required to keep the decoder outputs glitch-free. While CE is low, the outputs ( CE0 - CE3 )
will be defined by inputs A and B with a propagation delay of tPD from an A or B input change.
10. For applications where higher currents are required, please see the DS1259 Battery Manager Chip
data sheet.
5 of 8
DS1221
SECURITY OPTION
When activated by Dallas Semiconductor, the security option prevents unauthorized access. A sequence
of events must occur to gain access to the memories (Figure 3). First, a dummy read cycle or a 200 ns
active low reset pulse is executed to initialize the sequence. Second, a 64-bit access code must be
consecutively written to the DS1221 using the write enable signal ( WE ), the chip enable signal ( CE ), and
the data input/output signal (DQ). The code is written to the DS1221 without regard to the address.
Actual RAM locations are not written, as the security option is intercepting the data path until access is
granted. Instead, a special 64-bit write only register is written. Following the 64 write cycles, the register
is compared to a 64-bit pattern uniquely defined by the user and programmed into the DS1221 by Dallas
Semiconductor at the time of manufacture. This pattern can only be interrogated by an intelligent
controller within the DS1221 and cannot be read by the user. If a read cycle occurs before 64 write cycles
are completed, the security sequence is aborted. When a correct match for 64 bits is received, the third
part of the security sequence begins by reading a 64-bit read only register. This register consists of 64 bits
also defined by the user and programmed into the DS1221 by Dallas Semiconductor at the time of
manufacture. For each of the 64 read cycles, 1 bit of the user-defined read only register is driven onto the
DQ line. This phase also requires that the 64 read cycles be consecutive. The data being read from the
read only register can be used by software to determine if the DS1221 will be permitted to be used with
that particular system. After the 64th read cycle has been executed the DS1221 is unlocked and all
subsequent memory cycles will be passed through and will become actual memory accesses based upon
address inputs. If VCC falls below 4.5 volts or the reset line is driven low, the entire security sequence
must be executed again in order to access memory locations.
NOTE:
Contact Dallas Semiconductor sales office for code assignments.
SECURITY OPTION
AC ELECTRICAL CHARACTERISTICS
PARAMETER
Read Cycle Time
CE Access Time
RD Access Time
CE to Output Low Z
RD to Output Low Z
CE to Output High Z
RD to Output High Z
Read Recovery
Write Cycle
Write Pulse Width
Write Recovery
Data Setup
Data Hold Time
CE Pulse Width
Reset Pulse Width
SYMBOL
tRC
tCO
tOE
tCOE
tOEE
tOD
tODO
tRR
tWC
tWP
tWR
tDS
tDH
tCW
tRST
(0°C to 70°C; VCC = 5V ± 10%)
MIN
250
TYP
MAX
200
100
10
10
100
100
50
250
170
50
100
0
170
200
6 of 8
UNITS
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
NOTES
DS1221
POWER-DOWN Figure 5
POWER-UP Figure 6
7 of 8
DS1221
READ CYCLE TO SECURITY OPTION Figure 7
WRITE CYCLE TO SECURITY OPTION Figure 8
NOTES:
1. tDH and tDS are functions of the first occurring edge of WE or CE .
2. tWR is a function of the latter occurring edge of WE or CE .
RESET FOR SECURITY OPTION Figure 9