TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 Temperature and Power Supply System Monitors Check for Samples: TMP512, TMP513 FEATURES DESCRIPTION • • • • • • • • • • The TMP512 (dual-channel) and TMP513 (triple-channel) are system monitors that include remote sensors, a local temperature sensor, and a high-side current shunt monitor. These system monitors have the capability of measuring remote temperatures, on-chip temperatures, and system voltage/power/current consumption. 1 234 • • ±1°C REMOTE DIODE SENSORS ±1°C LOCAL TEMPERATURE SENSOR SERIES RESISTANCE CANCELLATION n-FACTOR CORRECTION TEMPERATURE ALERT FUNCTION AVERAGING 12-BIT RESOLUTION DIODE FAULT DETECTION SENSES BUS VOLTAGES FROM 0V TO +26V REPORTS CURRENT IN AMPS, VOLTAGE IN VOLTS AND POWER IN WATTS HIGH ACCURACY: 1% MAX OVER TEMP WATCHDOG LIMITS: – Upper Over-Limit – Lower Under-Limit APPLICATIONS • • • • • • DESKTOP AND NOTEBOOK COMPUTERS SERVERS INDUSTRIAL CONTROLLERS CENTRAL OFFICE TELECOM EQUIPMENT LCD/ DLP®/LCOS PROJECTORS STORAGE AREA NETWORKS (SAN) The remote temperature sensor diode-connected transistors are typically low-cost, NPN- or PNP-type transistors or diodes that are an integral part of microcontrollers, microprocessors, or FPGAs. Remote accuracy is ±1°C for multiple IC manufacturers, with no calibration needed. The two-wire serial interface accepts SMBus™ or two-wire write and read commands. The onboard current shunt monitor is a high-side current shunt and power monitor. It monitors both the shunt drop and supply voltage. A programmable calibration value (along with the TMP512/TMP513 internal digital multiplier) enables direct readout in amps; an additional multiplication calculates power in watts. The TMP512 and TMP513 both feature two separate onboard watchdog capabilities: an over-limit comparator and a lower-limit comparator. These devices use a single +3V to +26V supply, drawing a maximum of 1.4mA of supply current, and they are specified for operation from –40°C to +125°C. TMP512 TMP513 Mux DXP1 Low-Pass Filter DXN1 ADC DXP2 DXN2 Internal Diode Temperature Sensor DXP3 DXN3 V+ Subregulator 3.3V Filter C A0 Power Register ALERT Current Register VIN+ Two-Wire Interface ADC VIN- Voltage Register GND SDA SCL GPIO 1 2 3 4 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. DLP is a registered trademark of Texas Instruments. SMBus is a trademark of Intel Corporation. All other trademarks are the property of their respective owners. UNLESS OTHERWISE NOTED this document contains PRODUCTION DATA information current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 2010, Texas Instruments Incorporated TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications. PACKAGE INFORMATION (1) PRODUCT PACKAGE-LEAD PACKAGE DESIGNATOR PACKAGE MARKING TMP512 SO-14 D TMP512A SO-16 D TMP513A QFN-16 (2) RSA TMP513A TMP513 (1) (2) For the most current package and ordering information see the Package Option Addendum at the end of this document, or visit the TMP512/TMP513 product folder at www.ti.com. Product preview device. ABSOLUTE MAXIMUM RATINGS (1) Over operating free-air temperature range (unless otherwise noted). Supply Voltage, V+ TMP512, TMP513 UNIT 26 V Voltage GND – 0.3 to +6 V Current 10 mA Differential (VIN+) – (VIN–) (2) –26 to +26 V Common-Mode –0.3 to +26 V GND – 0.3 to +6 V GND – 0.3 to V+ + 0.3 V Input Current Into Any Pin 5 mA Open-Drain Digital Output Current 10 mA –65 to +150 °C Filter C Analog Inputs, VIN+, VIN– Open-Drain Digital Outputs GPIO, DXP, DXN Storage Temperature Junction Temperature ESD Ratings (1) (2) 2 +150 °C Human Body Model (HBM) 2000 V Charged-Device Model (CDM) 1000 V Machine Model (MM) 150 V Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied. VIN+ and VIN– may have a differential voltage of –26V to +26V; however, the voltage at these pins must not exceed the range –0.3V to +26V. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 THERMAL INFORMATION THERMAL METRIC TMP512 TMP513AID TMP513AIRSAR TMP513AIRSAT D (SOIC) D (SOIC) RSA (1) 14 16 16 qJA Junction-to-ambient thermal resistance (2) 91.1 77.6 44.8 qJC(top) Junction-to-case(top) thermal resistance (3) 10.6 55.0 43.8 (4) qJB Junction-to-board thermal resistance 40.3 49.9 14.7 yJT Junction-to-top characterization parameter (5) 49.1 3.5 0.4 yJB Junction-to-board characterization parameter (6) 47.5 32.2 14.5 n/a n/a 2.6 qJC(bottom) (1) (2) (3) (4) (5) (6) (7) Junction-to-case(bottom) thermal resistance (7) UNITS °C/W For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953. The junction-to-ambient thermal resistance under natural convection is obtained in a simulation on a JEDEC-standard, high-K board, as specified in JESD51-7, in an environment described in JESD51-2a. The junction-to-case (top) thermal resistance is obtained by simulating a cold plate test on the package top. No specific JEDEC-standard test exists, but a close description can be found in the ANSI SEMI standard G30-88. The junction-to-board thermal resistance is obtained by simulating in an environment with a ring cold plate fixture to control the PCB temperature, as described in JESD51-8. The junction-to-top characterization parameter, yJT, estimates the junction temperature of a device in a real system and is extracted from the simulation data for obtaining qJA, using a procedure described in JESD51-2a (sections 6 and 7). The junction-to-board characterization parameter, yJB, estimates the junction temperature of a device in a real system and is extracted from the simulation data for obtaining qJA , using a procedure described in JESD51-2a (sections 6 and 7). The junction-to-case (bottom) thermal resistance is obtained by simulating a cold plate test on the exposed (power) pad. No specific JEDEC standard test exists, but a close description can be found in the ANSI SEMI standard G30-88. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 3 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com ELECTRICAL CHARACTERISTICS: V+ = +12V Boldface limits apply over the specified temperature range, TA = –40°C to +125°C. At TA = +25°C, V+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG (1) = 1, unless otherwise noted. TMP512, TMP513 PARAMETER TEST CONDITIONS MIN PGA = ÷ 1 PGA = ÷ 2 TYP MAX UNIT 0 ±40 mV 0 ±80 mV PGA = ÷ 4 0 ±160 mV PGA = ÷ 8 0 ±320 mV BRNG = 0 0 16 V BRNG = 1 0 32 VIN+ = 0V to 26V 100 INPUT Current Sense (Input) Voltage Range Bus Voltage (Input Voltage) Range (2) Common-Mode Rejection Offset Voltage, RTI (3) CMRR VOS PSRR ±10 ±100 mV PGA = ÷ 2 ±20 ±125 mV PGA = ÷ 4 ±30 ±150 mV PGA = ÷ 8 ±40 ±200 mV 0.2 mV/°C V+ = 3V to 5.5V, Configuration 3 (4) 10 mV/V V+ = 4.5V to 26V, subregulator supply 0.1 mV/V ±0.04 % 0.0025 % Current Sense Gain Error vs Temperature Input Impedance V dB PGA = ÷ 1 vs Temperature vs Power Supply 120 Active Mode VIN+ Pin 20 mA VIN– Pin 20 || 320 mA || kΩ Input Leakage Power-Down Mode VIN+ Pin 0.1 0.5 mA VIN– Pin 0.1 0.5 mA DC ACCURACY ADC Basic Resolution 12 Bits 1 LSB Step Size Shunt Voltage 10 mV Bus Voltage 4 mV Current Measurement Error ±0.2 over Temperature Bus Voltage Measurement Error ±0.2 over Temperature ±0.5 % ±1 % ±0.5 % ±1 Differential Nonlinearity ±0.1 % LSB ADC TIMING ADC Conversion Time (1) (2) (3) (4) 4 12-Bit 665 733 ms 11-Bit 345 380 ms 10-Bit 185 204 ms 9-Bit 105 117 ms BRNG is bit 13 of Configuration Register 1. This parameter only expresses the full-scale range of the ADC scaling. In no event should more than 26V be applied to this device. Referred-to-input (RTI). See Subregulator section. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 ELECTRICAL CHARACTERISTICS: V+ = +12V (continued) Boldface limits apply over the specified temperature range, TA = –40°C to +125°C. At TA = +25°C, V+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG (1) = 1, unless otherwise noted. TMP512, TMP513 PARAMETER TEST CONDITIONS MIN TYP MAX UNIT TEMPERATURE ERROR Local Temperature Sensor Remote Temperature Sensor (5) TELOCAL TEREMOTE vs Supply, Local vs Supply, Remote TA = –40°C to +125°C ±1.25 ±2.5 °C TA = +15°C to +85°C, V+ = 12V ±0.25 ±1 °C TA = +15°C to +85°C, TD = –40°C to+ 150°C, V+ = 12V ±0.25 ±1 °C TA = –40°C to +100°C, TD = –40°C to +150°C, V+ = 12V ±1 ±3 °C TA = –40°C to +125°C, TD = –40°C to +150°C ±3 ±5 °C V+ = 3V to 5.5V, Configuration 3 (6) 0.2 0.5 °C/V V+ = 3V to 5.5V, Configuration 3 (6) 0.2 0.5 °C/V V+ = 4.5V to 26V, subregulator supply 0.01 0.05 °C/V 115 130 ms TEMPERATURE MEASUREMENT Conversion Time (per channel) 100 Resolution Local Temperature Sensor 13 Bits Remote Temperature Sensor 13 Bits High 120 mA Medium High 60 mA Medium Low 12 mA Low 6 mA Remote Sensor Source Currents Default Non-Ideality Factor Series Resistance 3kΩ max n TMP512/12 Optimized Ideality Factor 1.008 SMBus Logic Input High Voltage (SCL, SDA, GPIO, A0) VIH Logic Input Low Voltage (SCL, SDA, GPIO, A0) VIL 2.1 0.8 Hysteresis 500 SMBus Output Low Sink Current SDA Output Low Voltage V mV 6 VOL IOUT = 6mA 0 ≤ VIN ≤ 6V Logic Input Current mA 0.15 –1 SMBus Input Capacitance (SCL, SDA, GPIO, A0) 0.4 V 1 mA 3 SMBus Clock Frequency SMBus Timeout (7) 25 V 30 SCL Falling Edge to SDA Valid Time pF 3.4 MHz 35 ms 1 ms POWER SUPPLY Specified Supply Range (6) +26 V Quiescent Current V+ +3 1 1.4 mA Quiescent Current, Power-Down Mode 55 100 mA Power-On Reset Threshold 2 V TEMPERATURE RANGE Specified Temperature Range (5) (6) (7) –40 +125 °C Tested with one-shot measurements, and with less than 5Ω effective series resistance, and with 100pF differential input capacitance. See Subregulator section. SMBus timeout in the TMP512/13 resets the interface any time SCL or SDA is low for over 28ms. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 5 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com PIN CONFIGURATIONS TMP512 space D PACKAGE SO-14 (TOP VIEW) Filter C 1 14 GND V+ 2 13 ALERT VIN+ 3 12 GPIO VIN- 4 11 DXN2 SDA 5 10 DXP2 SCL 6 9 DXN1 A0 7 8 DXP1 TMP512 TMP512: PIN DESCRIPTIONS 6 PIN NO. NAME DESCRIPTION 1 Filter C Subregulator output and filter capacitor pin. 2 V+ Positive supply voltage (3V to 26V) See Figure 20. 3 VIN+ Positive differential shunt voltage. Connect to positive side of shunt resistor. 4 VIN- Negative differential shunt voltage. Connect to negative side of shunt resistor. Bus voltage is measured from this pin to ground. 5 SDA Serial bus data line for SMBus, open-drain; requires pull-up resistor. 6 SCL Serial bus clock line for SMBus, open-drain; requires pull-up resistor. 7 A0 Address pin 8 DXP1 Channel 1 positive connection to remote temperature sensor. 9 DXN1 Channel 1 negative connection to remote temperature sensor. 10 DXP2 Channel 2 positive connection to remote temperature sensor. 11 DXN2 Channel 2 negative connection to remote temperature sensor. 12 GPIO General-purpose, user-programmable input/output. Totem-pole output. Connect to ground or supply through a resistor if not used. Default state is as an input. 13 ALERT Open-drain SMBus alert output. Controlled in SMBus Alert Mask Register. Default state is disabled. 14 GND Ground Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 TMP513 space D PACKAGE SO-16 (TOP VIEW) ALERT VIN+ 3 14 GPIO VIN- 4 13 DXN3 VIN+ 1 12 DXP3 VIN- 2 ALERT 15 13 2 GND V+ 14 GND Filter C 16 15 1 V+ Filter C 16 RSA PACKAGE(1) QFN-16 (TOP VIEW) 12 GPIO 11 DXN3 TMP513 SDA 5 TMP513 A0 7 10 DXP2 SCL 4 9 DXN2 DXP1 8 9 DXN1 (1) 8 DXP3 DXP2 10 7 3 DXN1 SDA 6 DXN2 DXP1 11 5 6 A0 SCL Product preview device. TMP513: PIN DESCRIPTIONS D PACKAGE SO-16 RSA PACKAGE QFN-16 NAME DESCRIPTION 1 15 Filter C Subregulator output and filter capacitor pin. 2 16 V+ 3 1 VIN+ Positive differential shunt voltage. Connect to positive side of shunt resistor. 4 2 VIN- Negative differential shunt voltage. Connect to negative side of shunt resistor. Bus voltage is measured from this pin to ground. 5 3 SDA Serial bus data line for SMBus, open-drain; requires pull-up resistor. 6 4 SCL Serial bus clock line for SMBus, open-drain; requires pull-up resistor. 7 5 A0 8 6 DXP1 Channel 1 positive connection to remote temperature sensor. 9 7 DXN1 Channel 1 negative connection to remote temperature sensor. 10 8 DXP2 Channel 2 positive connection to remote temperature sensor. 11 9 DXN2 Channel 2 negative connection to remote temperature sensor. 12 10 DXP3 Channel 3 positive connection to remote temperature sensor. 13 11 DXN3 Channel 3 negative connection to remote temperature sensor. 14 12 GPIO General-purpose, user-programmable input/output. Totem-pole output. Connect to ground or supply through a resistor if not used. Default state is as an input. 15 13 ALERT 16 14 GND Positive supply voltage (3V to 26V) See Figure 20. Address pin Open-drain SMBus alert output. Controlled in SMBus Alert Mask Register. Default state is disabled. Ground Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 7 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com TYPICAL CHARACTERISTICS: V+ = +12V At TA = +25°C, V+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG = 1, unless otherwise noted. FREQUENCY RESPONSE REMOTE TEMPERATURE ERROR vs TEMPERATURE 0 Remote Temperature Error (?C) -10 -20 Gain (dB) -30 -40 -50 -60 -70 -80 -90 -100 1k 100 10 10k 100k 6 5 4 3 2 1 0 -1 -2 -3 -4 -5 -6 34 Units Shown 0 -40 -25 1M 25 Figure 1. LOCAL TEMPERATURE ERROR vs TEMPERATURE SHUNT OFFSET vs TEMPERATURE 40mV Range 10 80mV Range 1.0 0.5 Offset (mV) Local Temperature Error (°C) 14 Units Shown 0 -0.5 5 0 320mV Range -5 160mV Range -1.0 -10 -1.5 -2.0 -40 -25 -15 0 25 50 75 100 0 -40 -25 125 25 Ambient Temperature (°C) 75 100 125 Figure 4. SHUNT GAIN ERROR vs TEMPERATURE BUS VOLTAGE OFFSET vs TEMPERATURE 250 35 30 200 25 150 32V Range 20 320mV Range Offset (mV) Gain Error (m%) 50 Temperature (°C) Figure 3. 160mV Range 50 80mV Range 15 10 5 16V Range 0 0 -5 -10 40mV Range -100 -40 -25 0 25 50 75 100 125 -15 -40 -25 0 25 50 75 100 125 Temperature (°C) Temperature (°C) Figure 5. 8 125 15 1.5 -50 100 Figure 2. 2.0 100 75 50 Ambient Temperature (?C) Input Frequency (Hz) Figure 6. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 TYPICAL CHARACTERISTICS: V+ = +12V (continued) At TA = +25°C, V+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG = 1, unless otherwise noted. INTEGRAL NONLINEARITY vs INPUT VOLTAGE 20 200 15 10 150 32V Range 100 INL (mV) Gain Error (m%) BUS GAIN ERROR vs TEMPERATURE 250 50 5 0 -5 0 -10 16V Range -50 -15 -100 0 -40 -25 25 50 75 100 -20 -0.4 125 -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 Input Voltage (V) Temperature (°C) Figure 7. Figure 8. INPUT CURRENTS WITH LARGE DIFFERENTIAL VOLTAGES (VIN+ at 12V, Sweep of VIN–) ACTIVE IQ vs TEMPERATURE 2.0 1.4 V+ = 5.5V Current into VIN- V+ = 5.5V 1.5 1.2 1.0 0.5 IQ (mA) Input Currents (mA) V+ = 12V 1.0 V+ = 3V 0 V+ = 3V -0.5 V+ = 3V 0.8 0.6 0.4 -1.0 0.2 Current into VIN+ V+ = 5.5V -1.5 0 5 10 15 20 25 30 0 -40 -25 VIN- Voltage (V) 0 25 50 75 100 125 Temperature (°C) Figure 9. Figure 10. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 9 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com TYPICAL CHARACTERISTICS: V+ = +12V (continued) At TA = +25°C, V+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG = 1, unless otherwise noted. SHUTDOWN IQ vs SUPPLY VOLTAGE SHUTDOWN IQ vs TEMPERATURE 120 140 120 100 V+ = 5.5V 80 80 IQ (mA) IQ (mA) 100 V+ = 12V 60 60 40 40 V+ = 3V 20 20 Note: Shutdown IQ vs Temperature is for Subregulator Configurations 1 and 2 Note: Shutdown IQ vs VS is for Subregulator Configuration 3 0 0 -40 -25 0 25 50 75 100 125 2.5 3.0 3.5 4.0 4.5 5.0 5.5 VS (V) Temperature (°C) Figure 11. Figure 12. ACTIVE IQ vs TWO-WIRE CLOCK FREQUENCY SHUTDOWN IQ vs TWO-WIRE CLOCK FREQUENCY 1100 250 V+ = 12V 1050 200 IQ (mA) IQ (mA) V+ = 12V V+ = 3.3V 1000 950 150 100 900 V+ = 3.3V 50 850 800 0 1k 10k 100k 1M 10M 1k SCL Frequency (Hz) 100k 1M 10M SCL Frequency (Hz) Figure 13. 10 10k Figure 14. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 TYPICAL CHARACTERISTICS: V+ = +12V (continued) At TA = +25°C, V+ = 12V, VSENSE = (VIN+ – VIN–) = 32mV, PGA = ÷ 1, and BRNG = 1, unless otherwise noted. REMOTE TEMPERATURE ERROR vs SERIES RESISTANCE (GND Collector-Connected Transistor, 2N3906 PNP) 2.0 2.0 1.5 1.5 Remote Temperature Error (°C) Remote Temperature Error (°C) REMOTE TEMPERATURE ERROR vs SERIES RESISTANCE (Diode-Connected Transistor, 2N3906 PNP) 1.0 0.5 0 -0.5 -1.0 -1.5 Note: For all three subregulator configurations. -2.0 1.0 0.5 0 -0.5 -1.0 -1.5 Note: For all three subregulator configurations. -2.0 0 500 1000 1500 2000 2500 3000 3500 0 500 1000 RS (W) 1500 2000 2500 3000 3500 RS (W) Figure 15. Figure 16. REMOTE TEMPERATURE ERROR vs DIFFERENTIAL CAPACITANCE Remote Temperature Error (°C) 3 2 1 0 -1 -2 -3 0 0.5 1.0 1.5 2.0 2.5 3.0 Capacitance (nF) Figure 17. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 11 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com PARAMETRIC MEASUREMENT INFORMATION TYPICAL CONNECTIONS SERIES RESISTANCE CONFIGURATION (a) GND Collector-Connected Transistor RS1 (1) DXP DXN RS2 (1) (b) Diode-Connected Transistor RS1 (1) DXP DXN RS2 (1) (1) RS1 + RS2 should be less than 1kΩ; see Filtering section. Figure 18. DIFFERENTIAL CAPACITANCE CONFIGURATION (a) GND Collector-Connected Transistor DXP CDIFF (1) DXN (b) Diode-Connected Transistor DXP CDIFF (1) DXN (1) CDIFF should be less than 2200pF; see Filtering section. Figure 19. 12 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 APPLICATION INFORMATION DESCRIPTION The TMP512/13 are digital temperature sensors with a digital current-shunt monitor that combine a local die temperature measurement channel and remote junction temperature measurement channels: two for the TMP512 and three for the TMP513. The TMP512/13 contain multiple registers for holding configuration information, temperature, and voltage measurement results. These devices provide digital current, voltage, and power readings necessary for accurate decision-making in precisely-controlled systems. Programmable registers allow flexible configuration for setting warning limits, measurement resolution, and continuous-versus-triggered operation. Detailed register information appears at the end of this data sheet, beginning with Table 3. For proper remote temperature sensing operation, the TMP512 requires transistors connected between DXP1 and DXN1 and between DXP2 and DXN2, and for the TMP513, between DXP3 and DXN3 as well. Unused channels on the TMP512/13 must be connected to GND. The TMP512/13 offer compatibility with two-wire and SMBus interfaces. The two-wire and SMBus protocols are essentially compatible with each other. Two-wire is used throughout this data sheet, with SMBus being specified only when a difference Bus Voltage Range = 4.5V to 26V V+ = 4.5V to 26V SUBREGULATOR The subregulator can be configured to three different modes of operation. Each mode has its advantage and limitation. Figure 20 shows the three configuration arrangements. The minimum capacitance on the Filter C pin for Configurations 1 and 2 is 470nF. The minimum capacitance on the Filter C pin for Configuration 3 is 100nF. Configuration 1 has V+ and VIN+ tied together. V+ supplies the subregulator, which in turn supplies the 3.3V to the Filter C pin and the internal die. With the V+ supply range of 4.5V to 26V connected to the shunt voltage, the bus voltage range cannot go to zero and is limited to 4.5V to 26V. Configuration 2 has V+ to the subregulator without any other connections. Under this configuration, the bus voltage range can go from 0V to 26V, because it is not limited to 4.5V as in Configuration 1. Configuration 3 has the subregulator V+ and Filter C pins shorted together. V+ is limited to 3V to 5.5V because the Filter C pin supplies the internal die; it cannot exceed this voltage range. The bus voltage range can go from 0V to 26V, because it is not limited to 4.5V as in Configuration 1. Bus Voltage Range = 0V to 26V V+ = 4.5V to 26V Subregulator 3.3V Filter C Bus Voltage Range = 0V to 26V V+ = 3V to 5.5V Subregulator 3.3V Filter C 470nF 100nF VIN+ VIN+ ADC Shunt RSHUNT VIN- Load ADC Shunt RSHUNT VIN- Load GND ADC VIN- Load GND Configuration 1 Subregulator 3.3V Filter C 470nF VIN+ Shunt RSHUNT between the two systems is being addressed. Two bi-directional lines, SCL and SDA, connect the TMP512/13 to the bus. SDA is an open-drain connection. See Figure 21 for a typical application circuit. GND Configuration 2 Configuration 3 Figure 20. Typical Subregulator Configurations Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 13 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com SERIES RESISTANCE CANCELLATION Series resistance in an application circuit that typically results from printed circuit board (PCB) trace resistance and remote line length is automatically cancelled by the TMP512/13, preventing what would otherwise result in a temperature offset. A total of up to 3kΩ of series line resistance is cancelled by the TMP512/13, eliminating the need for additional characterization and temperature offset correction. See the Remote Temperature Error vs Series Resistance typical characteristic curves (Figure 15 ) for details on the effects of series resistance and power-supply voltage on sensed remote temperature error. DIFFERENTIAL INPUT CAPACITANCE The TMP512/13 can tolerate differential input capacitance of up to 2200pF with minimal change in temperature error. The effect of capacitance on sensed remote temperature error is illustrated in Figure 16, Remote Temperature Error vs Differential Capacitance. See the Filtering section for suggested component values where filtering unwanted coupled signals is needed. TEMPERATURE MEASUREMENT DATA Temperature measurement data may be taken over an operating range of –40°C to +125°C for both local and remote locations. The Temperature Register of the TMP512/13 is configured as a 13-bit, read-only register that stores the output of the most recent conversion. Two bytes must be read to obtain data, and are described in the 14 Local Temperature Result Register and the Remote Temperature Result Registers. Note that byte 1 is the most significant byte, followed by byte 2, the least significant byte. The first 13 bits are used to indicate temperature. The least significant byte does not have to be read if that information is not needed. The data format for temperature is summarized in Table 10. One LSB equals 0.0625°C. Negative numbers are represented in binary twos complement format. Following power-up or reset, the Temperature Register will read 0°C until the first conversion is complete. Unused bits in the Temperature Register always read '0'. REGISTER INFORMATION The TMP512/13 contain multiple registers for holding configuration information, temperature and voltage measurement results, and status information. These registers are described in Table 3. POINTER REGISTER The 8-bit Pointer Register is used to address a given data register. The Pointer Register identifies which of the data registers should respond to a read or write command on the two-wire bus. This register is set with every write command. A write command must be issued to set the proper value in the Pointer Register before executing a read command. Table 3 describes the pointer address of the TMP512/13 registers. The power-on reset (POR) value of the Pointer Register is 00h (0000 0000b). Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 n-FACTOR CORRECTION REGISTER The TMP512/13 allow for a different n-factor value to be used for converting remote channel measurements to temperature. The remote channel uses sequential current excitation to extract a differential VBE voltage measurement to determine the temperature of the remote transistor. Equation 1 describes this voltage and temperature. I nkT VBE2 - VBE1 = In 2 q I1 (1) ( ( The value n in Equation 1 is a characteristic of the particular transistor used for the remote channel. The power-on reset value for the TMP512/13 is n = 1.008. The value in the n-Factor Correction Register may be used to adjust the effective n-factor according to Equation 2 and Equation 3. 1.008 ´ 300 neff = (300 - NADJUST) (2) The 300 ´ 1.008 neff n-factor value ( ( NADJUST = 300 - must (3) be stored in twos-complement format, yielding an effective data range from –128 to +127. The n-factor value may be written to and read from pointer address 16h for remote channel 1, pointer address 17h for remote channel 2, and pointer address 18h for remote channel 3. The register power-on reset value is 00h, thus having no effect unless the register is written to. BUS OVERVIEW The device that initiates the transfer is called a master, and the devices controlled by the master are slaves. The bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and generates START and STOP conditions. To address a specific device, the master initiates a START condition by pulling the data signal line (SDA) from a HIGH to a LOW logic level while SCL is HIGH. All slaves on the bus shift in the slave address byte on the rising edge of SCL, with the last bit indicating whether a read or write operation is intended. During the ninth clock pulse, the slave being addressed responds to the master by generating an Acknowledge and pulling SDA LOW. TMP512 TMP513 MUX DXP1 Low-Pass Filter DXN1 ADC DXP2 DXN2 DXP3 Internal Diode Temperature Sensor DXN3 V+ Subregulator 3.3V Filter C 3.3V Supply ´ VIN- Two-Wire Interface Current Register VIN+ Current Shunt A0 Power Register ADC ALERT SDA SMBus Controller SCL Voltage Register Load GND GPIO Figure 21. Typical Application Circuit Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 15 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com Data transfer is then initiated and eight bits of data are sent, followed by an Acknowledge bit. During data transfer, SDA must remain stable while SCL is HIGH. Any change in SDA while SCL is HIGH is interpreted as a START or STOP condition. Once all data have been transferred, the master generates a STOP condition, indicated by pulling SDA from LOW to HIGH while SCL is HIGH. The TMP512/13 includes a 28ms timeout on its interface to prevent locking up an SMBus. SERIAL BUS ADDRESS To communicate with the TMP512/13, the master must first address slave devices via a slave address byte. The slave address byte consists of seven address bits, and a direction bit indicating the intent of executing a read or write operation. The TMP512/13 feature an address pin to allow up to four devices to be addressed on a single bus. Table 1 describes the pin logic levels used to properly connect up to four devices. The state of the A0 pin is sampled on every bus communication and should be set before any activity on the interface occurs. The address pin is read at the start of each communication event. Table 1. TMP512/13 Address Pins and Slave Addresses DEVICE TWO-WIRE ADDRESS A0 PIN CONNECTION 1011100 Ground 1011101 V+ 1011110 SDA 1011111 SCL SERIAL INTERFACE The TMP512/13 operate only as slave devices on the two-wire bus and SMBus. SCL is an input only, and TMP512/13 cannot drive it. Connections to the bus are made via the open-drain I/O lines SDA and SCL. The SDA and SCL pins feature integrated spike suppression filters and Schmitt triggers to minimize the effects of input spikes and bus noise. The TMP512/13 support the transmission protocol for fast (1kHz to 400kHz) and high-speed (1kHz to 3.4MHz) modes. All data bytes are transmitted MSB first. 16 WRITING TO/READING FROM THE TMP512/13 Accessing a particular register on the TMP512/13 is accomplished by writing the appropriate value to the register pointer. Refer to Table 3 for a complete list of registers and corresponding addresses. The value for the register pointer as shown in Figure 24 is the first byte transferred after the slave address byte with the R/W bit LOW. Every write operation to the TMP512/13 requires a value for the register pointer. Writing to a register begins with the first byte transmitted by the master. This byte is the slave address, with the R/W bit LOW. The TMP512/13 then acknowledge receipt of a valid address. The next byte transmitted by the master is the address of the register to which data will be written. This register address value updates the register pointer to the desired register. The next two bytes are written to the register addressed by the register pointer. The TMP512/13 acknowledge receipt of each data byte. The master may terminate data transfer by generating a START or STOP condition. When reading from the TMP512/13, the last value stored in the register pointer by a write operation determines which register is read during a read operation. To change the register pointer for a read operation, a new value must be written to the register pointer. This write is accomplished by issuing a slave address byte with the R/W bit LOW, followed by the register pointer byte. No additional data are required. The master then generates a START condition and sends the slave address byte with the R/W bit HIGH to initiate the read command. The next byte is transmitted by the slave and is the most significant byte of the register indicated by the register pointer. This byte is followed by an Acknowledge from the master; then the slave transmits the least significant byte. The master acknowledges receipt of the data byte. The master may terminate data transfer by generating a Not-Acknowledge after receiving any data byte, or generating a START or STOP condition. If repeated reads from the same register are desired, it is not necessary to continually send the register pointer bytes; the TMP512/13 retain the register pointer value until it is changed by the next write operation. Figure 22 and Figure 23 show read and write operation timing diagrams, respectively. Note that register bytes are sent most-significant byte first, followed by the least significant byte. See Figure 25 for an illustration of a typical register pointer configuration. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com Start By Master 1 1 1 1 0 1 1 1 A1 A0 (1) 9 1 D15 D14 ACK By TMP512/TMP513 R/W Frame 1 Two-Wire Slave Address Byte 1 1 1 A1 A0 (1) 9 1 P7 ACK By TMP512/TMP513 R/W P6 P4 P3 P2 D13 P1 D12 D11 D10 D9 (2) D8 From TMP512/TMP513 Frame 2 Data MSByte P0 9 1 D15 D14 ACK By TMP512/TMP513 Frame 2 Register Pointer Byte P5 D13 9 1 D8 D7 ACK By Master D9 D6 9 D5 1 D7 ACK By TMP512/TMP513 Frame 3 Data MSByte D12 D11 D10 NOTES: (1) The value of the Slave Address Byte is determined by the settings of the A0 pin. Refer to Table 1. (2) Read data is from the last register pointer location. If a new register is desired, the register pointer must be updated. See Figure 23. (3) ACK by Master can also be sent. 0 Frame 1 Two-Wire Slave Address Byte D4 D3 D2 From TMP512/TMP513 D5 D4 D3 D1 (2) D2 Frame 3 Data LSByte D6 D0 9 9 NoACK By Master D0 D1 (3) ACK By TMP512/TMP513 Frame 4 Data LSByte Stop Stop By Master Product Folder Link(s): TMP512 TMP513 17 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated SCL SDA SCL SDA Start By Master NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 pin. Refer to Table 1. Figure 23. Timing Diagram for Read Word Format Figure 22. Timing Diagram for Write Word Format TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com ALERT 1 9 1 9 SCL SDA 0 0 0 1 1 0 0 1 R/W Start By Master 0 1 1 ACK By TMP512/TMP513 1 A1 A0 0 From NACK By TMP512/TMP513 Master Frame 1 SMBus ALERT Response Address Byte Frame 2 Slave Address Byte Stop By Master (1) NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 pin. Refer to Table 1. Figure 24. Timing Diagram for SMBus ALERT 1 9 1 9 SCL ¼ SDA 1 0 1 1 Start By Master 1 A1 A0 R/W P7 P6 P5 P4 P3 P2 ACK By TMP512/TMP513 Frame 1 Two-Wire Slave Address Byte (1) P1 P0 Stop ACK By TMP512/TMP513 Frame 2 Register Pointer Byte NOTE (1): The value of the Slave Address Byte is determined by the settings of the A0 pin. Refer to Table 1. Figure 25. Typical Register Pointer Set 18 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 TIMING DIAGRAMS Figure 26 describes the timing operations on the TMP512/13. Parameters for Figure 26 are defined in Table 2. Bus definitions are: Bus Idle: Both SDA and SCL lines remain high. Start Data Transfer: A change in the state of the SDA line, from high to low, while the SCL line is high, defines a START condition. Each data transfer initiates with a START condition. Denoted as S in Figure 26. Stop Data Transfer: A change in the state of the SDA line from low to high while the SCL line is high defines a STOP condition. Each data transfer terminates with a repeated START or STOP condition. Denoted as P in Figure 26. t(LOW) Data Transfer: The number of data bytes transferred between a START and a STOP condition is not limited and is determined by the master device. The receiver acknowledges data transfer. Acknowledge: Each receiving device, when addressed, is obliged to generate an Acknowledge bit. A device that acknowledges must pull down the SDA line during the Acknowledge clock pulse in such a way that the SDA line is stable low during the high period of the Acknowledge clock pulse. Setup and hold times must be taken into account. On a master receive, data transfer termination can be signaled by the master generating a Not-Acknowledge on the last byte that has been transmitted by the slave. tF tR t(HDSTA) SCL t(HDSTA) t(HIGH) t(HDDAT) t(SUSTO) t(SUSTA) t(SUDAT) SDA t(BUF) P S S P Figure 26. Two-Wire Timing Diagram Table 2. Timing Characteristics for Figure 26 FAST MODE PARAMETER HIGH-SPEED MODE MIN MAX MIN MAX UNIT 0.4 0.001 3.4 MHz SCL Operating Frequency f(SCL) 0.001 Bus Free Time Between STOP and START Condition t(BUF) 600 160 ns Hold time after repeated START condition. After this period, the first clock is generated. t(HDSTA) 100 100 ns Repeated START Condition Setup Time t(SUSTA) 100 100 ns STOP Condition Setup Time t(SUSTO) 100 100 ns Data Hold Time t(HDDAT) 0 (1) 0 (2) ns Data Setup Time t(SUDAT) 100 10 ns SCL Clock LOW Period t(LOW) 1300 160 ns SCL Clock HIGH Period t(HIGH) 600 60 ns Clock/Data Fall Time tF 300 160 Clock/Data Rise Time tR 300 160 tR 1000 for SCL ≤ 100kHz (1) (2) ns ns For cases with fall time of SCL less than 20ns and/or the rise or fall time of SDA less than 20ns, the hold time should be greater than 20ns. For cases with a fall time of SCL less than 10ns and/or the rise or fall time of SDA less than 10ns, the hold time should be greater than 10ns. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 19 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com HIGH-SPEED MODE SENSOR FAULT In order for the two-wire bus to operate at frequencies above 400kHz, the master device must issue a High-Speed mode (Hs-mode) master code (0000 1xxx) as the first byte after a START condition to switch the bus to high-speed operation. The TMP512/13 do not acknowledge this byte, but switch the input filters on SDA and SCL and the output filter on SDA to operate in Hs-mode, allowing transfers at up to 3.4MHz. After the Hs-mode master code has been issued, the master transmits a START condition to a two-wire slave address that initiates a data transfer operation. The bus continues to operate in Hs-mode until a STOP condition occurs on the bus. Upon receiving the STOP condition, the TMP512/13 switch the input and output filters back to Fast mode operation. The TMP512/13 can sense an open circuit. Short-circuit conditions return a value of –256°C. The detection circuitry consists of a voltage comparator that trips when the voltage at DXP exceeds (V+) – 0.6V (typical). The comparator output is continuously checked during a conversion. If a fault is detected, the OPEN bit (bit 0) in the temperature result register is set to '1' and the rest of the register bits should be ignored. POWER-UP CONDITIONS Power-up conditions apply to a software reset via the RST bit (bit 15) in the Configuration Register, or the two-wire bus General Call Reset. At device power up, all Status bits are masked, and the SMBus Alert function is disabled. All watchdog outputs default to active low and transparent (non-latched) modes. SHUTDOWN MODE The TMP512/13 shutdown mode of operation allows the user flexibility to shut down the shunt/bus voltage measurement and the temperature measurement functions individually. To shut down the shunt/bus voltage measurement function immediately, set bits 2 through 0 in Configuration Register 1 (00h) to '000' respectively. To shut down the shunt/bus voltage measurement after the end of the current conversion, set bits 2 through 0 in Configuration Resister 1 (00h) to '100' respectively. To shut down the temperature measurement function immediately, set bits 15 through 11 in Configuration Register 2 (01h) to '00000' respectively. To shut down the temperature measurement after the end of the current conversion, set bit 15 in Configuration Register 2 (01h) to '0'. UNDERVOLTAGE LOCKOUT The TMP512/13 sense when the power-supply voltage has reached a minimum voltage level for the ADC to function. The detection circuitry consists of a voltage comparator that enables the ADC after the power supply (V+) exceeds 2.7V (typical). The comparator output is continuously checked during a conversion. The TMP512/13 do not perform a temperature conversion if the power supply is not valid. The PVLD bit (see Status Register; Local Temperature Reset Register; Remote Temperature Reset 1, 2 and 3 Registers) of the individual Local/Remote Temperature Result Registers are set to '1' and the temperature result may be incorrect. TEMPERATURE AVERAGING The TMP512/13 average the input diode voltages that determine the remote temperature by sampling multiple times throughout a conversion. The temperature result can be extracted from four different VBE readings and is sampled 600 times in 130ms (max). Each VBE voltage is sampled 150 times through integration capacitors that average the results throughout the conversion time. A delta-sigma (ΔΣ) modulator and digital filter integrate the VBE voltages and create a sync filter averaging system. In addition, a low-pass filter is present at the input of the converter with a cutoff frequency of 65kHz. This integrating topology offers superior noise immunity. FILTERING ONE-SHOT COMMAND For the TMP512/13, when the temperature core is in shutdown and the voltage core is in triggered mode, a single conversion is started on all enabled channels by writing a '1' to the OS bit in Configuration Register 1. This write operation starts one conversion; the TMP512/13 returns to shutdown mode when that conversion completes. At the end of the conversion, the Conversion Ready flags (bit 6 and bit 5) in the Status Register are set to indicate end of conversion. 20 When not using the remote sensor with the TMP512/13, the DXP and DXN inputs must be connected together to prevent meaningless fault warnings. Remote junction temperature sensors are usually implemented in a noisy environment. Noise is frequently generated by fast digital signals and if not filtered properly will induce errors that can corrupt temperature measurements. The TMP512/13 have a built-in 65kHz filter on the inputs of DXP and DXN to minimize the effects of noise. However, a bypass capacitor placed differentially across the inputs of the remote temperature sensor is recommended to make the application more robust against unwanted Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 Where: n = ideality factor of remote temperature sensor. T(°C) = actual temperature. TERR = error in TMP512/13 because n ≠ 1.008. Degree delta is the same for °C and K. For n = 1.004 and T(°C) = 100°C: 1.004 - 1.008 TERR = ´ 273.15 + 100°C) 1.008 ( ( ) coupled signals. The value of this capacitor should be between 100pF and 1nF. Some applications attain better overall accuracy with additional series resistance; however, this increased accuracy is application-specific. When series resistance is added, the total value should not be greater than 3kΩ. If filtering is needed, suggested component values are 100pF and 50Ω on each input; exact values are application-specific. GENERAL CALL RESET The TMP512/13 support reset via the two-wire General Call address 00h (0000 0000b). The TMP512/13 acknowledge the General Call address and respond to the second byte. If the second byte is 06h (0000 0110b), the TMP512/13 execute a software reset state to all TMP512/13 registers, and abort any conversion in progress. The TMP512/13 take no action in response to other values in the second byte. REMOTE SENSING The TMP512/13 are designed to be used with either discrete transistors or substrate transistors built into processor chips and ASICs. Either NPN or PNP transistors can be used, as long as the base-emitter junction is used as the remote temperature sense. NPN transistors must be diode-connected. PNP transistors can either be transistoror diode-connected, as Figure 18 and Figure 19 show. Errors in remote temperature sensor readings are typically the consequence of the ideality factor and current excitation used by the TMP512/13 versus the manufacturer-specified operating current for a given transistor. Some manufacturers specify a high-level and low-level current for the temperature-sensing substrate transistors. The TMP512/13 use 6mA for ILOW and 120mA for IHIGH. The ideality factor (n) is a measured characteristic of a remote temperature sensor diode as compared to an ideal diode. The TMP512/13 allow for different n-factor values; see the n-Factor Correction Register section. The ideality factor for the TMP512/13 is trimmed to be 1.008. For transistors that have an ideality factor that does not match the TMP512/13, Equation 4 can be used to calculate the temperature error. Note that for the equation to be used correctly, actual temperature (°C) must be converted to kelvins (K). ( ( TERR = n - 1.008 ´ 273.15 + T(°C) 1.008 space (4) TERR = 1.48°C (5) If a discrete transistor is used as the remote temperature sensor with the TMP512/13, the best accuracy can be achieved by selecting the transistor according to the following criteria: 1. Base-emitter voltage > 0.25V at 6mA, at the highest sensed temperature. 2. Base-emitter voltage < 0.95V at 120mA, at the lowest sensed temperature. 3. Base resistance < 100Ω. 4. Tight control of VBE characteristics indicated by small variations in hFE (that is, 50 to 150). Based on these criteria, two recommended small-signal transistors are the 2N3904 (NPN) or 2N3906 (PNP). BASIC ADC FUNCTIONS The two analog inputs to the TMP512/13, VIN+ and VIN–, connect to a shunt resistor in the bus of interest. The TMP512/13 are powered by an internal subregulator, which has a typical output of 3.3V. The bus being sensed can vary from 0V to 26V. There are no special considerations for power-supply sequencing (for example, a bus voltage can be present with the supply voltage off, and vice-versa). The TMP512/13 sense the small drop across the shunt for shunt voltage, and sense the voltage with respect to ground from VIN– for the bus voltage. See Figure 27 for an illustration of this operation. When the TMP512/13 are in the normal operating mode (that is, MODE bits of Configuration Register 1 are set to '111'), the devices continuously convert the shunt voltage up to the number set in the shunt voltage averaging function (Configuration Register 1, SADC bits). The devices then convert the bus voltage up to the number set in the bus voltage averaging (Configuration Register 1, BADC bits). The Mode control in Configuration Register 1 also permits selecting modes to convert only voltage or current, either continuously or in response to a two-wire command. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 21 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com TMP512 TMP513 MUX DXP1 Low-Pass Filter DXN1 ADC DXP2 DXN2 DXP3 Internal Diode Temperature Sensor DXN3 V+ Subregulator 3.3V Filter C 3.3V Supply ´ VSHUNT = VIN+ - VINTypically < 50mV VIN- ALERT SDA Two-Wire Interface Current Register VIN+ Current Shunt A0 Power Register ADC SMBus Controller SCL Voltage Register Load GPIO VBUS = VIN- - GND Range of 0V to 26V Typical Application: 12V GND Figure 27. TMP512/13 Configured for Shunt and Bus Voltage Measurement All current and power calculations are performed in the background and do not contribute to conversion time; conversion times shown in the Electrical Characteristics table can be used to determine the actual conversion time. Power-Down mode reduces the quiescent current and turns off current into the TMP512/13 inputs, avoiding any supply drain. Full recovery from Power-Down requires 40ms. ADC Off mode (set by Configuration Register 1, MODE bits) stops all conversions. Although the TMP512/13 can be read at any time, and the data from the last conversion remain available, the Conversion Ready bit and the Conversion Ready Temperature bit (Status Register, CVR and CRT) are provided to help co-ordinate one-shot or triggered conversions. The Conversion Ready bit and the Conversion Ready Temperature bit are set after all conversions, averaging, and multiplication operations are complete. 22 The Conversion Ready bit and the Conversion Ready Temperature bit clear when reading the Status Register or triggering a single-shot conversion. POWER MEASUREMENT Current and bus voltage are converted at different points in time, depending on the resolution and averaging mode settings. For instance, when configured for 12-bit and 128 sample averaging, up to 81ms in time between sampling these two values is possible. Again, these calculations are performed in the background and do not add to the overall conversion time. PGA FUNCTION If larger full-scale shunt voltages are desired, the TMP512/13 provide a PGA function that increases the full-scale range up to 2, 4, or 8 times (320mV). Additionally, the bus voltage measurement has two full-scale ranges: 16V or 32V. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 COMPATIBILITY WITH TI HOT-SWAP CONTROLLERS The TMP512/13 are designed for compatibility with hot-swap controllers such the TI TPS2490. The TPS2490 uses a high-side shunt with a limit at 50mV; the TMP512/13 full-scale range of 40mV enables the use of the same shunt for current sensing below this limit. When sensing is required at (or through) the 50mV sense point of the TPS2490, the PGA of the TMP512/13 can be set to ÷2 to provide an 80mV full-scale range. FILTERING AND INPUT CONSIDERATIONS Measuring current is often noisy, and such noise can be difficult to define. The TMP512/13 offer several options for filtering by choosing resolution and averaging in Configuration Register 1. These filtering options can be set independently for either voltage or current measurement. The internal ADC is based on a delta-sigma (ΔΣ) front-end with a 500kHz (±10%) typical sampling rate. This architecture has good inherent noise rejection; however, transients that occur at or very close to the sampling rate harmonics can cause problems. Because these signals are at 1MHz and higher, they can be dealt with by incorporating filtering at the input of the TMP512/13. The high frequency enables the use of low-value series resistors on the filter for negligible effects on measurement accuracy. Figure 28 shows the TMP512/13 with an additional filter added at the input. Overload conditions are another consideration for the TMP512/13 inputs. The TMP512/13 inputs are specified to tolerate 26V across the inputs. A large differential scenario might be a short to ground on the load side of the shunt. This type of event can result in full power-supply voltage across the shunt (as long the power supply or energy storage capacitors support it). It must be remembered that removing a short to ground can result in inductive kickbacks that could exceed the 26V differential and common-mode rating of the TMP512/13. Inductive kickback voltages are best dealt with by zener-type transient-absorbing devices (commonly called transzorbs) combined with sufficient energy storage capacitance. TMP512 TMP513 MUX DXP1 Low-Pass Filter DXN1 ADC DXP2 DXN2 DXP3 Internal Diode Temperature Sensor DXN3 V+ Subregulator 3.3V Filter C 3.3V Supply ´ A0 Power Register 10W Current Shunt VIN- Two-Wire Interface Current Register VIN+ ADC ALERT SDA SMBus Controller SCL Voltage Register 10W Load 0.1mF to 1mF Ceramic Capacitor GND GPIO Figure 28. TMP512/13 with Input Filtering Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 23 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com In applications that do not have large energy storage electrolytics on one or both sides of the shunt, an input overstress condition may result from an excessive dV/dt of the voltage applied to the input. A hard physical short is the most likely cause of this event, particularly in applications with no large electrolytics present. This problem occurs because an excessive dV/dt can activate the ESD protection in the TMP512/13 in systems where large currents are available. Testing has demonstrated that the addition of 10Ω resistors in series with each input of the TMP512/13 sufficiently protects the inputs against dV/dt failure up to the 26V rating of the TMP512/13. These resistors have no significant effect on accuracy. not generate an Acknowledge and continues to hold the ALERT line low until the interrupt is cleared. Successful completion of the read alert response protocol clears the SMBus ALERT pin, provided that the condition causing the alert no longer exists. The SMBus Alert flag is cleared separately by either reading the Status Register or by disabling the SMBus Alert function. SMBus ALERT RESPONSE The TMP512/13 GPIO can be used to control an external circuit to switch the VBUS measurement to an alternate location. Switching is most often done to perform bus voltage measurements on the opposite side of a MOSFET switch in series with the shunt resistor. The SMBus alert response functions only when the Alert pin is active and in latch mode (03h, bit 0 = 1); see Figure 24. The ALERT interrupt output signal is latched and can be cleared only by either reading the Status Register or by successfully responding to an alert response address. If the fault is still present, the ALERT pin re-asserts. Asserting the ALERT pin does not halt automatic conversions that are already in progress. The ALERT output pin is open-drain, allowing multiple devices to share a common interrupt line. The TMP512/13 respond to the SMBus alert response address, an interrupt pointer return-address feature. The SMBus alert response interrupt pointer provides quick fault identification for simple slave devices. When an ALERT occurs, the master can broadcast the alert response slave address (0001 100). Following this alert response, any slave devices that generated interrupts identify themselves by putting the respective addresses on the bus. The alert response can activate several different slave devices simultaneously, similar to the two-wire General Call. If more than one slave attempts to respond, bus arbitration rules apply; the device with the lower address code wins. The losing device does 24 The Status Register flags indicate which (if any) of the watchdogs have been activated. After power-on reset (POR), the normal state of all flag bits is '0', assuming that no alarm conditions exist. EXTERNAL CIRCUITRY FOR ADDITIONAL VBUS INPUT Consideration must be given to the typical 20mA input current of each TMP512/13 input, along with the 320kΩ impedance present at the VIN– input where the bus voltage is measured. These effects can create errors through the resistance of any external switching method used. The easiest way to avoid these errors is by reducing this resistance to a minimum; select switching MOSFETs with the lowest possible RDS(on) values. The circuit shown in Figure 29 uses MOSFET pairs to reduce package count. Back-to-back MOSFETs must be used in each leg because of the built-in back diodes from source-to-drain. In this circuit, the normal connection for VIN– is at the shunt, with the optional voltage measurement at the output of the control FET. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 TMP512 TMP513 MUX DXP1 Low-Pass Filter DXN1 ADC DXP2 DXN2 DXP3 Internal Diode Temperature Sensor DXN3 V+ Subregulator 3.3V Filter C 3.3V Supply ´ Current Register VIN+ Shunt RSHUNT A0 Power Register Two-Wire Interface ADC VIN- ALERT SDA SMBus Controller SCL Voltage Register GPIO GND 10kW Control FET N-Channel MOSFETs Dual pairs such as Vishay SI1034 P-Channel MOSFETs Dual pairs such as Vishay SI3991DV 10kW Load From Hot-Swap Controller N-Channel MOSFETs Dual pairs such as Vishay SI1034 Figure 29. External Circuitry for Additional VBUS Input Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 25 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com PROGRAMMING THE TMP512/13 POWER MEASUREMENT ENGINE Calibration Register and Scaling The Calibration Register makes it possible to set the scaling of the Current and Power Registers to whatever values are most useful for a given application. One strategy may be to set the Calibration Register such that the largest possible number is generated in the Current Register or Power Register at the expected full-scale point; this approach yields the highest resolution. The Calibration Register can also be selected to provide values in the Current and Power Registers that either provide direct decimal equivalents of the values being measured, or yield a round LSB number. After these choices have been made, the Calibration Register also offers possibilities for end user system-level calibration, where the value is adjusted slightly to cancel total system error. This section presents two examples for configuring the TMP512/13 calibration. Both examples are written so the information relates directly to the calibration setup found in the TMP512/13EVM software. Calibration Example 1: Calibrating the TMP512/13 with no possibility for overflow. NOTE The numbers used in this example are the same used with the TMP512/13EVM software as shown in Figure 30. 1. Establish the following parameters: VBUS_MAX = 32 VSHUNT_MAX = 0.32 RSHUNT = 0.5 2. Use Equation 6 to determine the maximum possible current . VSHUNT_MAX MaxPossible_I = RSHUNT MaxPossible_I = 0.64 (6) 3. Choose the desired maximum current value. This value is selected based on system expectations. Max_Expected_I = 0.6 4. Calculate the possible range of current LSBs. To calculate this range, first compute a range of LSBs that is appropriate for the design. Next, select an LSB within this range. Note that the results will have the most resolution when the minimum LSB is selected. Typically, an LSB is selected to be the nearest round number to the minimum LSB value. Max_Expected_I Minimum_LSB = 32767 Minimum_LSB = 18.311 ´ 10-6 (7) Max_Expected_I 4095 Maximum_LSB = 146.520 ´ 10-6 Maximum_LSB = (8) Choose an LSB in the range: Minimum_LSB < Selected_LSB < Maximum_LSB Current_LSB = 20 × 10–6 Note: This value was selected to be a round number near the Minimum_LSB. This selection allows for good resolution with a rounded LSB. 5. Compute the Calibration Register value using Equation 9: 0.04096 Cal = trunc Current_LSB ´ R SHUNT Cal = 4096 26 (9) Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 6. Calculate the Power LSB with Equation 10. Equation 10 shows a general formula; because the bus voltage measurement LSB is always 4mV, the power formula reduces to the calculated result. Power_LSB = 20 Current_LSB Power_LSB = 400 ´ 10-6 (10) 7. Compute the maximum current and shunt voltage values (before overflow), as shown by Equation 11 and Equation 12. Note that both Equation 11 and Equation 12 involve an If - then condition: Max_Current = Current_LSB ´ 32767 Max_Current = 0.65534 (11) If Max_Current ≥ MaxPossible_I then Max_Current_Before_Overflow = MaxPossible_I Else Max_Current_Before_Overflow = Max_Current End If (Note that Max_Current is greater than MaxPossible_I in this example.) Max_Current_Before_Overflow = 0.64 Max_ShuntVoltage = Max_Current_Before_Overflow ´ RSHUNT Max_ShuntVoltage = 0.32 (12) If Max_ShuntVoltage ≥ VSHUNT_MAX Max_ShuntVoltage_Before_Overflow = VSHUNT_MAX Else Max_ShuntVoltage_Before_Overflow= Max_ShuntVoltage End If (Note that Max_ShuntVoltage is greater than VSHUNT_MAX in this example.) Max_ShuntVoltage_Before_Overflow = 0.32 8. Compute the maximum power with Equation 13. MaximumPower = Max_Current_Before_Overflow ´ VBUS_MAX MaximumPower = 20.48 (13) 9. (Optional second Calibration step.) Compute corrected full-scale calibration value based on measured current. TMP513_Current = 0.63484 MeaShuntCurrent = 0.55 Corrected_Full_Scale_Cal = trunc Cal ´ MeasShuntCurrent TMP513_Current Corrected_Full_Scale_Cal = 3548 (14) Figure 30 illustrates how to perform the same procedure discussed in this example using the automated TMP512/13EVM software. Note that the same numbers used in this nine-step example are used in the software example. Note also that Figure 30 illustrates which results correspond to which step (for example, the information entered in Step 1 is enclosed in a box in Figure 30 and labeled). Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 27 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com Figure 30. TMP512/513EVM Calibration Software Automatically Computes Calibration Steps 1-9 28 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 Calibration Example 2 (Overflow Possible) This design example uses the nine-step procedure for calibrating the TMP512/13 where overflow is possible. Figure 31 illustrates how the same procedure is performed using the automated TMP512/13EVN software. The same numbers used in the nine-step example are used in the software example shown in Figure 31. Note also that Figure 31 illustrates which results correspond to which step (for example, the information entered in Step 1 is circled in Figure 31 and labeled). 1. Establish the following parameters: VBUS_MAX = 32 VSHUNT_MAX = 0.32 RSHUNT = 5 2. Determine the maximum possible current using Equation 15: VSHUNT_MAX MaxPossible_I = RSHUNT MaxPossible_I = 0.064 (15) 3. Choose the desired maximum current value: Max_Expected_I, ≤ MaxPossible_I. This value is selected based on system expectations. Max_Expected_I = 0.06 4. Calculate the possible range of current LSBs. This calculation is done by first computing a range of LSB's that is appropriate for the design. Next, select an LSB withing this range. Note that the results will have the most resolution when the minimum LSB is selected. Typically, an LSB is selected to be the nearest round number to the minimum LSB. Max_Expected_I Minimum_LSB = 32767 Minimum_LSB = 1.831 ´ 10-6 (16) Max_Expected_I 4095 Maximum_LSB = 14.652 ´ 10-6 Maximum_LSB = (17) Choose an LSB in the range: Minimum_LSB < Selected_LSB < Maximum_LSB Current_LSB = 1.9 × 10–6 Note: This value was selected to be a round number near the Minimum_LSB. This section allows for good resolution with a rounded LSB. 5. Compute the calibration register using Equation 18: Cal = trunc 0.04096 Current_LSB ´ RSHUNT Cal = 4311 (18) 6. Calculate the Power LSB using Equation 19. Equation 19 shows a general formula; because the bus voltage measurement LSB is always 4mV, the power formula reduces to calculate the result. Power_LSB = 20 Current_LSB Power_LSB = 38 ´ 10-6 (19) Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 29 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com 7. Compute the maximum current and shunt voltage values (before overflow), as shown by Equation 20 and Equation 21. Note that both Equation 20 and Equation 21 involve an If - then condition. Max_Current = Current_LSB ´ 32767 Max_Current = 0.06226 (20) If Max_Current ≥ MaxPossible_I then Max_Current_Before_Overflow = MaxPossible_I Else Max_Current_Before_Overflow = Max_Current End If (Note that Max_Current is less than MaxPossible_I in this example.) Max_Current_Before_Overflow = 0.06226 Max_ShuntVoltage = Max_Current_Before_Overflow ´ RSHUNT Max_ShuntVoltage = 0.3113 (21) If Max_ShuntVoltage ≥ VSHUNT_MAX Max_ShuntVoltage_Before_Overflow = VSHUNT_MAX Else Max_ShuntVoltage_Before_Overflow= Max_ShuntVoltage End If (Note that Max_ShuntVoltage is less than VSHUNT_MAX in this example.) Max_ShuntVoltage_Before_Overflow = 0.3113 8. Compute the maximum power with Equation 22. MaximumPower = Max_Current_Before_Overflow ´ VBUS_MAX MaximumPower = 1.992 (22) 9. (Optional second calibration step.) Compute the corrected full-scale calibration value based on measured current. TMP513_Current = 0.06226 MeaShuntCurrent = 0.05 Corrected_Full_Scale_Cal = trunc Cal ´ MeasShuntCurrent TMP513_Current Corrected_Full_Scale_Cal = 3462 30 (23) Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 Figure 31. TMP512/513EVM Calibration Software Automatically Computes Calibration Steps 1-9 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 31 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com REGISTER INFORMATION The TMP512/13 uses a bank of registers for holding configuration settings, measurement results, maximum/minimum limits, and status information. Table 3 summarizes the TMP512/13 registers. Register contents are updated 4ms after completion of the write command. Therefore, a 4ms delay is required between the completion of a write to a given register and a subsequent read of that register (without changing the pointer) when using SCL frequencies in excess of 1MHz. Table 3. Summary of Register Set POINTER ADDRESS (1) (2) (3) 32 POWER-ON RESET HEX REGISTER NAME FUNCTION BINARY HEX TYPE (1) 00 Configuration Register 1 All-register reset, settings for bus voltage range, PGA Gain, Bus ADC resolution/averaging, Shunt ADC resolution/averaging, one-shot, Operation Mode. 00111001 10011111 399F R/W 01 Configuration Register 2 TMP512 Settings for Temperature Continuous conversion, Remote Channels enable, Local Channel enable, resistance correction enable, Conversion rate bits, and GPIO mode bit and readback. 1011111110000x00 BF80/BF84 R/W 01 Configuration Register 2 TMP513 Settings for Temperature Continuous conversion, Remote Channels enable, Local Channel enable, resistance correction enable, Conversion rate bits, and GPIO mode bit and readback. 11111111 10000x00 FF80/FF84 R/W Contains the alert and conversion ready flags. 00000000 00000000 0000 R Contains masks to enable/disable the alert functions. 00000000 00000000 0000 R/W Shunt voltage measurement result. 00000000 00000000 0000 R Bus voltage measurement result. 00000000 00000000 0000 R Power measurement result. 00000000 00000000 0000 R Contains the value of the current flowing through the shunt resistor. 00000000 00000000 0000 R 02 Status Register 03 SMBus Alert Mask/Enable Control Register 04 Shunt Voltage Result 05 Bus Voltage Result 06 Power Result 07 Shunt Current Result (2) 08 Local Temperature Result Contains local temperature measurement result. 00000000 00000000 0000 R 09 Remote Temperature Result 1 Contains remote temperature measurement result. 00000000 00000000 0000 R 0A Remote Temperature Result 2 Contains remote temperature measurement result. 00000000 00000000 0000 R 0B (3) Remote Temperature Result 3 Contains remote temperature measurement result. 00000000 00000000 0000 R 0C Shunt Voltage Positive Limit Contains the positive limit for Shunt Voltage. 00000000 00000000 0000 R/W 0D Shunt Voltage Negative Limit Contains the negative limit for Shunt Voltage. 00000000 00000000 0000 R/W Contains the positive limit for Bus Voltage. 00000000 00000000 0000 R/W 00000000 00000000 0000 R/W Contains the positive limit for Power. 00000000 00000000 0000 R/W Contains positive limit for local temperature. 00101010 10000000 2A80 R/W 0E Bus Voltage Positive Limit 0F Bus Voltage Negative Limit Contains the negative limit for Bus Voltage. 10 Power Limit 11 Local Temperature Limit Type: R = Read-Only, R/W = Read/Write. Current Register defaults to '0' because the Calibration Register defaults to '0', yielding a zero current value until the Calibration Register is programmed. For TMP513 only. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 Table 3. Summary of Register Set (continued) POINTER ADDRESS POWER-ON RESET BINARY HEX TYPE (1) Contains positive limit for remote temperature. 00101010 10000000 2A80 R/W Remote Temperature Limit 2 Contains positive limit for remote temperature. 00101010 10000000 2A80 R/W 14 (4) Remote Temperature Limit 3 Contains positive limit for remote temperature. 00101010 10000000 2A80 R/W 15 Shunt Calibration Register Sets the current that corresponds to a full-scale drop across the shunt. 00000000 00000000 0000 R/W 16 n-Factor 1 Contains the N-factor value for Remote Channel 1 and Hysteresis for temperature limits. 00000000 00000000 0000 R/W HEX REGISTER NAME 12 Remote Temperature Limit 1 13 FUNCTION 17 n-Factor 2 Contains the N-factor value for Remote Channel 2. 00000000 00000000 0000 R/W 18 (4) n-Factor 3 Contains the N-factor value for Remote Channel 3. 00000000 00000000 0000 R/W 1E/FE Manufacturer ID Register Contains the Manufacturer ID. 01010101 11111111 55FF R 1F/FF TMP512 Device ID Register Contains the Device ID. 00100010 11111111 22FF R 1F/FF TMP513 Device ID Register Contains the Device ID. 00100011 11111111 23FF R (4) For TMP513 only. space space REGISTER DETAILS All TMP512/13 registers are 16-bit registers. 16-bit register data are sent in two 8-bit bytes via the two-wire interface. Configuration Register 1—Shunt Measurement Configuration 00h (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME RST ONESHOT BRNG PG1 PG0 BADC4 BADC3 BADC2 BADC1 SADC4 SADC3 SADC2 SADC1 MODE3 MODE2 MODE1 POR VALUE 0 0 1 1 1 0 0 1 1 0 0 1 1 1 1 1 Bit Descriptions RST: Reset Bit Bit 15 Setting this bit to '1' generates a system reset that is the same as power-on reset. Resets all registers to default values; this bit self-clears. ONE-SHOT One-Shot Bit Bit 14 Setting this bit to '1' generates a one-shot command. BRNG: Bus Voltage Range Bit 13 0 = 16V FSR 1 = 32V FSR (default value) PG: PGA (Shunt Voltage Only) Bits 12, 11 Sets PGA gain and range. Note that the PGA defaults to ÷8 (320mV range). Table 4 shows the gain and range for the various product gain settings. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 33 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com Table 4. PG Bit Settings (1) (1) PG1 PG0 GAIN RANGE 0 0 1 ±40mV 0 1 ÷2 ±80mV 1 0 ÷4 ±160mV 1 1 ÷8 ±320mV Shaded values are default. BADC: BADC Bus ADC Resolution/Averaging Bits 10–7 These bits adjust the Bus ADC resolution (9-, 10-, 11-, or 12-bit) or set the number of samples used when averaging results for the Bus Voltage Register (05h). SADC: SADC Shunt ADC Resolution/Averaging Bits 6–3 These bits adjust the Shunt ADC resolution (9-, 10-, 11-, or 12-bit) or set the number of samples used when averaging results for the Shunt Voltage Register (04h). BADC (Bus) and SADC (Shunt) ADC resolution/averaging and conversion time settings are shown in Table 5. Table 5. ADC Settings (1) (1) (2) ADC4 ADC3 ADC2 ADC1 MODE/SAMPLES CONVERSION TIME 0 X (2) 0 0 9-bit 105ms 0 X (2) 0 1 10-bit 185ms 0 X (2) 1 0 11-bit 345ms 0 X (2) 1 1 12-bit 665ms 1 0 0 0 12-bit 665ms 1 0 0 1 2 1.3ms 1 0 1 0 4 2.58ms 1 0 1 1 8 5.13ms 1 1 0 0 16 10.25ms 1 1 0 1 32 20.49ms 1 1 1 0 64 40.97ms 1 1 1 1 128 81.92ms Shaded values are default. X = Don't care. MODE: Operating Mode Bits 2–0 Selects continuous, triggered, or power-down mode of operation. These bits default to continuous shunt and bus measurement mode. The mode settings are shown in Table 6. Table 6. Mode Settings (1) (1) (2) (3) (4) 34 MODE3 MODE2 MODE1 MODE 0 0 0 Power-Down (2) 0 0 1 Shunt Voltage, Triggered (3) 0 1 0 Bus Voltage, Triggered (3) 0 1 1 Shunt and Bus, Triggered (3) 1 0 0 ADC Off (disabled) (4) 1 0 1 Shunt Voltage, Continuous 1 1 0 Bus Voltage, Continuous 1 1 1 Shunt and Bus, Continuous Shaded values are default. Combination '000' stops converter immediately. In triggered modes the converter goes to power down. It can be triggered by a write of '1' to bit 14 (One-Shot) in Configuration Register 1 or by the delay scheme of the temperature sensor core. See Table 7. Combination '100' stops the converter at conversion end. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 Configuration Register 2—Temperature Measurement Configuration 01h (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME CONT REN3 REN2 REN1 LEN RC R2 R1 R0 — — — — GP GPM1 GPM0 TMP512 POR VALUE 1 0 1 1 1 1 1 1 1 0 0 0 0 X 0 0 TMP513 POR VALUE 1 1 1 1 1 1 1 1 1 0 0 0 0 X 0 0 CONT: Continuous Conversion Bit 15 0: When all bits 14 to 11 are '0', the temp sensor core goes immediately to shutdown mode. When all bits 14 to 11 are not '0', the temp sensor core stops when all enabled conversions are done. When this bit is '0', a one-shot command can be triggered by writing a "1" to bit 14 of Configuration Register 1. 1: Continuous temperature conversion mode. REN3: Remote Channel 3 Enable (TMP513 only) Bit 14 0: Remote channel 3 disabled. 1: Remote channel 3 enabled. REN2: Remote Channel 2 Enable Bit 13 0: Remote channel 2 disabled. 1: Remote channel 2 enabled. REN1: Remote Channel 1 Enable Bit 12 0: Remote channel 1 disabled. 1: Remote channel 1 enabled. LEN: Local Temperature Enable Bit 11 0: Local temperature disabled. 1: Local temperature enabled. RC: Resistance Correction Bit 10 0: Resistance correction disabled. 1: Resistance correction enabled. R2, R1, R0: Conversion Rate Bits 9-7 These bits set the conversion rate as shown in Table 7. Table 7. Conversion Rate Settings (1) (1) (2) (3) R2 R1 R0 CONVERSIONS/SEC 0 0 0 0.0625 0 0 1 0.125 0 1 0 0.25 0 1 1 0.5 1 0 0 1 1 0 1 2 1 1 0 4 (2) 1 1 1 8 (3) Shaded values are default. Conversion rate shown is for only one or two enabled measurement channels. When three channels are enabled, the conversion rate is 2 and 2/3 conversions per second. When four channels are enabled, the conversion rate is 2 per second. Conversion rate shown is for only one enabled measurement channel. When two channels are enabled, the conversion rate is 4 conversions per second. When three channels are enabled, the conversion rate is 2 and 2/3 conversions per second. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 35 TMP512 TMP513 SBOS491 – JUNE 2010 • • • www.ti.com When all of the following conditions are met, the temperature sensor core triggers a single conversion of the voltage measurement core at the same rate as the conversion rate shown by bits R2 to R0. The conversion rate is different than '111'; There is at least one enabled temperature channel; and The voltage measurement core is in triggered mode of operation. The temperature sensor core triggers a single conversion of the ADC core at the same rate as the conversion rate shown by R2 to R0. GP: GPIO Read-Back Bit 2 Shows the state of the GPIO pin. GPM: GPIO Mode Bits 1-0 The GPIO mode settings are shown in Table 8. GPIO should not be left floating at start-up. Table 8. GPIO Mode Settings (1) (1) 36 GPM[1] GPM[0] GPIO PIN DESCRIPTION 0 0 Hi-Z 0 1 Hi-Z Use as an input for either of these modes. 1 0 0 Use to output 0 to GPIO pin 1 1 1 Use to output 1 to GPIO pin Shaded values are default. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 Status Register 02h (Read) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SHP SHN BVP BVN PWR LCL RM1 RM2 RM3 CVR CRT PVLD SMBA OVF — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 The Status Register flags activate whenever any limit is violated, and latch if the alert is in latch mode. In latch mode, these flags are cleared when the Status Register is read (if the limit is exceeded, then at next conversion end, the flag sets again). In transparent mode, these flags are cleared when any corresponding limit is not violated any longer. After power-up and initial setup, the Status Register should be read once to clear any flags set as a result of power-up values prior to setup. Bit Descriptions SHP: Shunt Positive Over-Voltage Bit 15 This bit is set to '1' when the result in the Shunt Voltage Register (04h) exceeds the level set in the Shunt Positive Limit Register (0Ch). SHN: Shunt Negative Under-Voltage Bit 14 This bit is set to '1' when the result in the Shunt Voltage Register (04h) goes below the level set in the Shunt Negative Limit Register (0Dh). BVP: Bus Positive Over-Voltage Bit 13 This bit is set to '1' when the result in the Bus Voltage Register (05h) exceeds the level set in the Bus Voltage Positive Limit Register (0Eh). BVN: Bus Negative Under-Voltage Bit 12 This bit is set to '1' when the result in the Bus Voltage Register (05h) goes below the level set in the Bus Voltage Negative Limit Register (0Fh). PWR: Power Over–Limit Bit 11 This bit is set to '1' when the result in the Power Register (06h) exceeds the level set in the Power Limit Register (10h). LCL: Local Temperature Over-Limit Bit 10 This bit is set to '1' when the result in the Local Temperature Result Register (08h) exceeds the level set in the Local Temperature Limit Register (11h) plus half of the temperature hysteresis. It clears in transparent mode when the result in the Local Temperature Result Register (08h) is below the level set in the Local Temperature Limit Register (11h) minus half of the temperature hysteresis. RM1: Remote Temperature 1 Over-Limit Bit 9 This bit is set to '1' when the result in the Remote Temperature Result 1 Register (09h) exceeds the level set in the Remote Temperature Limit 1 Register (12h) plus half of the temperature hysteresis. It also sets if, during conversion of remote channel 1, an open diode condition was detected. It clears in transparent mode when the result in the Remote Temperature Result 1 Register (09h) is below the level set in the Remote Temperature Limit 1 Register (12h) minus half of the temperature hysteresis, and the last conversion of channel 1 was done without open-diode detection. RM2: Remote Temperature 2 Over-Limit Bit 8 This bit is set to '1' when the result in the Remote Temperature Result 2 Register (0Ah) exceeds the level set in the Remote Temperature Limit 2 Register (13h) plus half of the temperature hysteresis. It also sets if, during conversion of remote channel 2, an open diode condition was detected. It clears in transparent mode when the result in the Remote Temperature Result 2 Register (0Ah) is below the level set in the Remote Temperature Limit 2 Register (13h) minus half of the temperature hysteresis, and the last conversion of channel 2 was done without open-diode detection. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 37 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com Bit Descriptions (continued) RM3: Remote Temperature 3 Over-Limit (TMP513 only) Bit 7 This bit is set to '1' when the result in the Remote Temperature Result 3 Register (0Bh) exceeds the level set in the Remote Temperature Limit 3 Register (14h) plus half of the temperature hysteresis. It sets also if during conversion of remote channel 3 an open diode condition was detected. It clears in transparent mode when the result in the Remote Temperature Result 3Register (0Bh) is below the level set in the Remote Temperature Limit 3 Register (14h) minus half of the temperature hysteresis and the last conversion of channel 3 was done without open-diode detection. CVR: Conversion Ready Bit 6 The Conversion Ready line is provided to help coordinate one-shot conversions for shunt voltage, bus voltage, current and power measurements. The Conversion bit is set after all conversions, averaging, and multiplication events are complete. Conversion Ready clears under the following conditions: 1. Writing to the One-Shot bit in Configuration Register 1. 2. Reading the Status Register. CRT: Conversion Ready Temperature Bit 5 The Conversion Ready Temperature line is provided to help coordinate one-shot conversions for local and remote temperature measurements. The Conversion bit is set after all enabled channels complete the respective conversions. Conversion Ready Temperature clears under the following conditions: 1. 2. Writing to the One-Shot bit in Configuration Register 1. Reading the Status Register. PVLD: Power Valid Error Bit 4 In latch mode, this bit is set to '1' when the brown-out detect fires during a conversion. The flag sets to '1' at the conversion end. It clears by reading the Status Register. SMBA: SMBus Alert Bit 3 This bit is set when the Alert pin is active. When in latch mode, it clears only on reading the Status Register, disabling the SMBus Alert function, or using SMBus Alert Response. In transparent mode, it clears when the triggering condition is not present. OVF: Math Overflow Bit 2 This bit is set to '1' if an arithmetic operation resulted in an overflow error. It indicates that current and power data may be meaningless. It does not set the Alert pin. 38 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 SMBus Alert Register—Mask and Alert Control Functions 03h (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SHPM SHNM BVPM BVNM PWRM LCLM R1M R2M R3M CVRM CRTM PVLM FC1 FC0 POL LATCH POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bits D4–D15 of the SMBus Alert Register mask correspond to bits D4 to D15 of the Status Register to prevent them from initiating an SMBus Alert. It does not prevent the Status Register bit from setting. Writing a '0' to an SMBus Alert Mask bit masks it from activating the SMBus Alert. All default values are '0'. Bit Descriptions SHPM: Shunt Positive Over-Voltage Mask Bit 15 0: SHP flag in Status Register cannot activate Alert pin. 1: SHP flag (when set to '1') in Status Register activates Alert pin. SHNM: Shunt Negative Under-Voltage Mask Bit 14 0: SHN flag in Status Register cannot activate Alert pin. 1: SHN flag (when set to '1') in Status Register activates Alert pin. BVPM: Bus Voltage Positive Over-Voltage Mask Bit 13 0: BVP flag in Status Register cannot activate Alert pin. 1: BVP flag (when set to '1') in Status Register activates Alert pin. BVNM: Bus Voltage Negative Under-Voltage Mask Bit 12 0: BVN flag in Status Register cannot activate Alert pin. 1: BVN flag (when set to '1') in Status Register activates Alert pin. PWRM: Power Over-Limit Mask Bit 11 0: PWR flag in Status Register cannot activate Alert pin. 1: PWR flag (when set to '1') in Status Register activates Alert pin. LCLM: Local Temperature Over-Limit Mask Bit 10 0: LCL flag in Status Register cannot activate Alert pin. 1: LCL flag (when set to '1') in Status Register activates Alert pin. R1M: Remote Temperature1 Over-Limit Mask Bit 9 0: RM1 flag in Status Register cannot activate Alert pin. 1: RM1 flag (when set to '1') in Status Register activates Alert pin. R2M: Remote Temperature2 Over-Limit Mask Bit 8 0: RM2 flag in Status Register cannot activate Alert pin. 1: RM2 flag (when set to '1') in Status Register activates Alert pin. R3M: Remote Temperature3 Over-Limit Mask (TMP513 only) Bit 7 0: RM3 flag in Status Register cannot activate Alert pin. 1: RM3 flag (when set to '1') in Status Register activates Alert pin. CVRM: Conversion Ready Mask Bit 6 0: CVR flag in Status Register cannot activate Alert pin. 1: CVR flag (when set to '1') in Status Register activates Alert pin. CRTM: Conversion Ready Temperature Mask Bit 5 0: CRT flag in Status Register cannot activate Alert pin. 1: CRT flag (when set to '1') in Status Register activates Alert pin. PVLM: Power Valid Limit Mask Bit 4 0: PVLD flag in Status Register cannot activate Alert pin. 1: PVLD flag (when set to '1') in Status Register activates Alert pin. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 39 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com Bit Descriptions (continued) FC0, FC1 Fault Count Control Bits The Fault Count Control Bits affect flags in SMBus Alert Register bits D15-D7. Bit 3, 2 00: These flags are activated after the first conversion result with a violated limit. 01: These flags are activated after the second consecutive conversion result with a violated limit. 10: These flags are activated after the fourth consecutive conversion result with a violated limit. 11: These flags are activated after the eighth consecutive conversion result with a violated limit. POL: Alert Polarity Bit 1 0: Alert pin is active low. 1: Alert pin is active high. LATCH: Alert Mode of Operation Bit 0 0: Alert pin works in transparent mode. The SMB alert response function does not function. Alert is deasserted when the triggering condition goes away. 1: Alert pin works in latch mode. The SMB alert response function functions when Alert pin is active. Alert will remain asserted even if the triggering condition goes away. Alert can be deasserted by reading the Status register (02h), using the SMBus Alert response function, resetting the part, or by disabling the alert function using the mask bits. 40 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 Shunt Voltage Register 04h (Read-Only) The Shunt Voltage Register stores the current shunt voltage reading, VSHUNT. Shunt Voltage Register bits are shifted according to the PGA setting selected in Configuration Register 1 (00h). When multiple sign bits are present, they will all be the same value. Negative numbers are represented in twos complement format. Generate the twos complement of a negative number by complementing the absolute value binary number and adding 1. Extend the sign, denoting a negative number by setting the MSB = '1'. Extend the sign to any additional sign bits to form the 16-bit word. Example: For a value of VSHUNT = –320mV: 1. Take the absolute value (include accuracy to 0.01mV)==> 320.00 2. Translate this number to a whole decimal number ==> 32000 3. Convert it to binary==> 111 1101 0000 0000 4. Complement the binary result : 000 0010 1111 1111 5. Add 1 to the Complement to create the twos complement formatted result ==> 000 0011 0000 0000 6. Extend the sign and create the 16-bit word: 1000 0011 0000 0000 = 8300h (Remember to extend the sign to all sign-bits, as necessary based on the PGA setting.) At PGA = ÷8, full-scale range = ±320mV (decimal = 32000, positive value hex = 7D00, negative value hex = 8300), and LSB = 10mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SIGN SD14_8 SD13_8 SD12_8 SD11_8 SD10_8 SD9_8 SD8_8 SD7_8 SD6_8 SD5_8 SD4_8 SD3_8 SD2_8 SD1_8 SD0_8 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 At PGA = ÷4, full-scale range = ±160mV (decimal = 16000, positive value hex = 3E80, negative value hex = C180), and LSB = 10mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SIGN SIGN SD13_4 SD12_4 SD11_4 SD10_4 SD9_4 SD8_4 SD7_4 SD6_4 SD5_4 SD4_4 SD3_4 SD2_4 SD1_4 SD0_4 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 At PGA = ÷2, full-scale range = ±80mV (decimal = 8000, positive value hex = 1F40, negative value hex = E0C0), and LSB = 10mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SIGN SIGN SIGN SD12_2 SD11_2 SD10_2 SD9_2 SD8_2 SD7_2 SD6_2 SD5_2 SD4_2 SD3_2 SD2_2 SD1_2 SD0_2 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 At PGA = ÷1, full-scale range = ±40mV (decimal = 4000, positive value hex = 0FA0, negative value hex = F060), and LSB = 10mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SIGN SIGN SIGN SIGN SD11_1 SD10_1 SD9_1 SD8_1 SD7_1 SD6_1 SD5_1 SD4_1 SD3_1 SD2_1 SD1_1 SD0_1 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 41 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com Table 9. Shunt Voltage Register Format (1) VSHUNT Reading (mV) Decimal Value PGA = ÷ 8 (D15…..................D0) PGA = ÷ 4 (D15…..................D0) PGA = ÷ 2 (D15…..................D0) PGA = ÷ 1 (D15…..................D0) 320.02 32002 0111 1101 0000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 320.01 32001 0111 1101 0000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 320.00 32000 0111 1101 0000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 319.99 31999 0111 1100 1111 1111 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 319.98 31998 0111 1100 1111 1110 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 160.02 16002 0011 1110 1000 0010 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 160.01 16001 0011 1110 1000 0001 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 160.00 16000 0011 1110 1000 0000 0011 1110 1000 0000 0001 1111 0100 0000 0000 1111 1010 0000 159.99 15999 0011 1110 0111 1111 0011 1110 0111 1111 0001 1111 0100 0000 0000 1111 1010 0000 159.98 15998 0011 1110 0111 1110 0011 1110 0111 1110 0001 1111 0100 0000 0000 1111 1010 0000 80.02 8002 0001 1111 0100 0010 0001 1111 0100 0010 0001 1111 0100 0000 0000 1111 1010 0000 80.01 8001 0001 1111 0100 0001 0001 1111 0100 0001 0001 1111 0100 0000 0000 1111 1010 0000 80.00 8000 0001 1111 0100 0000 0001 1111 0100 0000 0001 1111 0100 0000 0000 1111 1010 0000 79.99 7999 0001 1111 0011 1111 0001 1111 0011 1111 0001 1111 0011 1111 0000 1111 1010 0000 79.98 7998 0001 1111 0011 1110 0001 1111 0011 1110 0001 1111 0011 1110 0000 1111 1010 0000 40.02 4002 0000 1111 1010 0010 0000 1111 1010 0010 0000 1111 1010 0010 0000 1111 1010 0000 40.01 4001 0000 1111 1010 0001 0000 1111 1010 0001 0000 1111 1010 0001 0000 1111 1010 0000 40.00 4000 0000 1111 1010 0000 0000 1111 1010 0000 0000 1111 1010 0000 0000 1111 1010 0000 39.99 3999 0000 1111 1001 1111 0000 1111 1001 1111 0000 1111 1001 1111 0000 1111 1001 1111 39.98 3998 0000 1111 1001 1110 0000 1111 1001 1110 0000 1111 1001 1110 0000 1111 1001 1110 0.02 2 0000 0000 0000 0010 0000 0000 0000 0010 0000 0000 0000 0010 0000 0000 0000 0010 0.01 1 0000 0000 0000 0001 0000 0000 0000 0001 0000 0000 0000 0001 0000 0000 0000 0001 0 0 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 –0.01 –1 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 –0.02 –2 1111 1111 1111 1110 1111 1111 1111 1110 1111 1111 1111 1110 1111 1111 1111 1110 –39.98 –3998 1111 0000 0110 0010 1111 0000 0110 0010 1111 0000 0110 0010 1111 0000 0110 0010 –39.99 –3999 1111 0000 0110 0001 1111 0000 0110 0001 1111 0000 0110 0001 1111 0000 0110 0001 –40.00 –4000 1111 0000 0110 0000 1111 0000 0110 0000 1111 0000 0110 0000 1111 0000 0110 0000 –40.01 –4001 1111 0000 0101 1111 1111 0000 0101 1111 1111 0000 0101 1111 1111 0000 0110 0000 –40.02 –4002 1111 0000 0101 1110 1111 0000 0101 1110 1111 0000 0101 1110 1111 0000 0110 0000 –79.98 –7998 1110 0000 1100 0010 1110 0000 1100 0010 1110 0000 1100 0010 1111 0000 0110 0000 –79.99 –7999 1110 0000 1100 0001 1110 0000 1100 0001 1110 0000 1100 0001 1111 0000 0110 0000 –80.00 –8000 1110 0000 1100 0000 1110 0000 1100 0000 1110 0000 1100 0000 1111 0000 0110 0000 –80.01 –8001 1110 0000 1011 1111 1110 0000 1011 1111 1110 0000 1100 0000 1111 0000 0110 0000 –80.02 –8002 1110 0000 1011 1110 1110 0000 1011 1110 1110 0000 1100 0000 1111 0000 0110 0000 –159.98 –15998 1100 0001 1000 0010 1100 0001 1000 0010 1110 0000 1100 0000 1111 0000 0110 0000 –159.99 –15999 1100 0001 1000 0001 1100 0001 1000 0001 1110 0000 1100 0000 1111 0000 0110 0000 –160.00 –16000 1100 0001 1000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –160.01 –16001 1100 0001 0111 1111 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –160.02 –16002 1100 0001 0111 1110 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –319.98 –31998 1000 0011 0000 0010 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –319.99 –31999 1000 0011 0000 0001 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –320.00 –32000 1000 0011 0000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –320.01 –32001 1000 0011 0000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 –320.02 –32002 1000 0011 0000 0000 1100 0001 1000 0000 1110 0000 1100 0000 1111 0000 0110 0000 (1) 42 Out-of-range values are shaded. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 Bus Voltage Register 05h (Read-Only) The Bus Voltage Register stores the most recent bus voltage reading, VBUS. At full-scale range = 32V (decimal = 8000, hex = 1F40), and LSB = 4mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BD12 BD11 BD10 BD9 BD8 BD7 BD6 BD5 BD4 BD3 BD2 BD1 BD0 — — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 At full-scale range = 16V (decimal = 4000, hex = 0FA0), and LSB = 4mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME 0 BD11 BD10 BD9 BD8 BD7 BD6 BD5 BD4 BD3 BD2 BD1 BD0 — — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Power Register 06h (Read-Only) Full-scale range and LSB are set by the Calibration Register. See the Programming the TMP512/13 Power Measurement Engine section. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME PD15 PD14 PD13 PD12 PD11 PD10 PD9 PD8 PD7 PD6 PD5 PD4 PD3 PD2 PD1 PD0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 The Power Register records power in watts by multiplying the values of the current with the value of the bus voltage according to the equation: Current ´ BusVoltage Power = 5000 Current Register 07h (Read-Only) Full-scale range and LSB depend on the value entered in the Calibration Register. See the Programming the TMP512/13 Power Measurement Engine section. Negative values are stored in twos complement format. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME CSIGN CD14 CD13 CD12 CD11 CD10 CD9 CD8 CD7 CD6 CD5 CD4 CD3 CD2 CD1 CD0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 The value of the Current Register is calculated by multiplying the value in the Shunt Voltage Register with the value in the Calibration Register according to the equation: Current = ShuntVoltage ´ Calibration Register 4096 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 43 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com Local Temperature Result Register 08h (Read-Only) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME T12 T11 T10 T9 T8 T7 T6 T5 T4 T3 T2 T1 T0 — PVLD — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 The data format is 13 bits, 0.0625°C per bit. Full-scale allows display up to ±256°C. T12–T0: Temperature Result Bits 15-3 Shows the temperature result according to the format shown in Table 10. Table 10. 13-Bit Temperature Data Format TEMPERATURE (°C) DIGITAL OUTPUT (BINARY) HEX 150 0 1001 0110 0000 0960 128 0 1000 0000 0000 0800 127.9375 0 0111 1111 1111 07FF 100 0 0110 0100 0000 0640 80 0 0101 0000 0000 0500 75 0 0100 1011 0000 04B0 50 0 0011 0010 0000 0320 25 0 0001 1001 0000 0190 0.25 0 0000 0000 0100 0004 0 0 0000 0000 0000 0000 –0.25 1 1111 1111 1100 1FFC –25 1 1110 0111 0000 1E70 –55 1 1100 1001 0000 1C90 For positive temperatures (for example, +50°C): Twos complement is not performed on positive numbers. Therefore, simply convert the number to binary code with the 13-bit, left-justified format, and MSB = 0 to denote a positive sign. Example: (+50°C)/(0.0625°C/count) = 800 = 320h = 0011 0010 0000 For negative temperatures (for example, –25°C): Generate the twos complement of a negative number by complementing the absolute value binary number and adding 1. Denote a negative number with MSB = 1. Example: (–25°C)/(0.0625°C/count) = 400 = 190h = 0001 1001 0000 Twos complement format: 1110 0110 1111 + 1 = 1110 0111 0000 PVLD Power Valid Flag Bit 1 This bit is the power valid flag. The TMP512/13 do not start a temperature conversion if the power supply is not valid. If the voltage is less than 2.7V during a conversion, the PVLD bit is set to '1' and the temperature result may be incorrect. 44 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 Remote Temperature Result 1 Register 09h, Remote Temperature Result 2 Register 0Ah, Remote Temperature Result 3 Register (TMP513 Only) 0Bh (Read-Only) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME RT12 RT11 RT10 RT9 RT8 RT7 RT6 RT5 RT4 RT3 RT2 RT1 RT0 — PVLD DO POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 The data format is 13 bits, 0.0625°C per bit. Full-scale allows display up to ±256°C. RT12–RT0: Remote Temperature Result Bits 3-15 Shows the remote temperature measurement result. PVLD Power Valid Flag Bit 1 This bit is the power valid flag. The TMP512/13 do not start a temperature conversion if the power supply is not valid. If the voltage is less than 2.7V during a conversion, the PVLD bit is set to '1' and the temperature result may be incorrect. DO Diode Open Flag Bit 0 This bit is the diode open flag. If the Remote Channels are open during a conversion, then Diode Open bit is set at the end of the conversion. Shunt Positive Limit Register 0Ch (Read/Write) At full-scale range = ±320mV, 15-bit + sign, LSB = 10mV (decimal = 32000, positive value hex = 7D00, negative value hex = 8300). BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SWP SIGN SWP14 SWP13 SWP12 SWP11 SWP10 SWP9 SWP8 SWP7 SWP6 SWP5 SWP4 SWP3 SWP2 SWP1 SWP0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Shunt Negative Limit Register 0Dh (Read/Write) At full-scale range = ±320mV (decimal = 32000, positive value hex = 7D00, negative value hex = 8300). 15 bit + sign, LSB = 10mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME SWN SIGN SWN14 SWN13 SWN12 SWN11 SWN10 SWN9 SWN8 SWN7 SWN6 SWN5 SWN4 SWN3 SWN2 SWN1 SWN0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bus Voltage Positive Limit Register 0Eh (Read/Write) At full-scale range = 32V (decimal = 8000, hex = 1F40), and LSB = 4mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BWU12 BWU11 BWU10 BWU9 BWU8 BWU7 BWU6 BWU5 BWU4 BWU3 BWU2 BWU1 BWU0 — — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 45 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com Bus Voltage Negative Limit Register 0Fh (Read/Write) At full-scale range = 32V (decimal = 8000, hex = 1F40), and LSB = 4mV. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BUO12 BUO11 BUO10 BUO9 BUO8 BUO7 BUO6 BUO5 BUO4 BUO3 BUO2 BUO1 BUO0 — — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Power Limit Register 10h (Read/Write) At full-scale range, same as the Power Register (06h). BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME PW15 PW14 PW13 PW12 PW11 PW10 PW9 PW8 PW7 PW6 PW5 PW4 PW3 PW2 PW1 PW0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Local Temperature Limit Register 11h, Remote Temperature Limit 1 Register 12h, Remote Temperature Limit 2 Register 13h, Remote Temperature Limit 3 Register 14h (TMP513 Only) (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME TH12 TH11 TH10 TH9 TH8 TH7 TH6 TH5 TH4 TH3 TH2 TH1 TH0 — — — POR VALUE 0 0 1 0 1 0 1 0 1 0 0 0 0 0 0 0 The data format is 13 bits. TH12–TH0: Temperature Limit Bits 15-3 Shows the temperature limit. Shunt Calibration Register 15h (Read/Write) Current and power calibration are set in the Calibration Register. Note that bit D0 is not used in the calculation. This register sets the current that corresponds to a full-scale drop across the shunt. Full-scale range and the LSB of the current and power measurement depend on the value entered in this register. See the Programming the TMP512/13 Power Measurement Engine section. This register is suitable for use in overall system calibration. Note that the '0' POR values are all default. BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 (1) BIT NAME FS15 FS14 FS13 FS12 FS11 FS10 FS9 FS8 FS7 FS6 FS5 FS4 FS3 FS2 FS1 FS0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (1) 46 D0 is a void bit and is always '0'. It is not possible to write a '1' to D0. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 TMP512 TMP513 www.ti.com SBOS491 – JUNE 2010 n-Factor 1 Register 16h (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME NF7 NF6 NF5 NF4 NF3 NF2 NF1 NF0 HST7 HST6 HST5 HST4 HST3 HST2 HST1 HST0 POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 NF7–NF0: n-Factor Bits Bits 15-8 Shows the n-factor for Channel 1 according to the range indicated in Table 11. Table 11. n-Factor Range (1) NADJUST (1) BINARY HEX DECIMAL n 0111 1111 7F 127 1.747977 0000 1010 0A 10 1.042759 0000 1000 08 8 1.035616 0000 0110 06 6 1.028571 0000 0100 04 4 1.021622 0000 0010 02 2 1.014765 0000 0001 01 1 1.011371 0000 0000 00 0 1.008 1111 1111 FF –1 1.004651 1111 1110 FE –2 1.001325 1111 1100 FC –4 0.994737 1111 1010 FA –6 0.988235 1111 1000 F8 –8 0.981818 1111 0110 F6 –10 0.975484 1000 0000 80 –128 0.706542 Shaded values are default. HST7–HST0: Hysteresis Register Bits Bits 7-0 The hysteresis register is binary coded. 1LSB is equal to 0.5°C, so the possible hysteresis range is 0°C to 127.5°C. n-Factor 2 Register 17h (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME NF7 NF6 NF5 NF4 NF3 NF2 NF1 NF0 — — — — — — — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 NF7–NF0: n-Factor Bits Bits 15-8 Shows the n-factor for Channel 2 according to the range indicated in Table 11. n-Factor 3 Register 18h (TMP513 Only) (Read/Write) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME NF7 NF6 NF5 NF4 NF3 NF2 NF1 NF0 — — — — — — — — POR VALUE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 NF7–NF0: n-Factor Bits Bits 15-8 Shows the n-factor for Channel 3 according to the range indicated in Table 11. Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 47 TMP512 TMP513 SBOS491 – JUNE 2010 www.ti.com Manufacturer ID Register 1Eh and FEh (Read-Only) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME ID7 ID6 ID5 ID4 ID3 ID2 ID1 ID0 — — — — — — — — POR VALUE 0 1 0 1 0 1 0 1 1 1 1 1 1 1 1 1 ID7–ID0: Identification Register Bits Bits 15-8 These bits provide the manufacturer ID. Device ID Register 1Fh and FFh (Read-Only) BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME DID7 DID6 DID5 DID4 DID3 DID2 DID1 DID0 — — — — — — — — TMP512 POR VALUE 0 0 1 0 0 0 1 0 1 1 1 1 1 1 1 1 TMP513 POR VALUE 0 0 1 0 0 0 1 1 1 1 1 1 1 1 1 1 DID7–DID0: Identification Register Bits Bits 15-8 These bits provide the device ID. 48 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated Product Folder Link(s): TMP512 TMP513 PACKAGE OPTION ADDENDUM www.ti.com 2-Jul-2010 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Qty Eco Plan (2) Lead/ Ball Finish MSL Peak Temp (3) Samples (Requires Login) TMP512AID ACTIVE SOIC D 14 50 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR Purchase Samples TMP512AIDR ACTIVE SOIC D 14 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR Request Free Samples TMP513AID ACTIVE SOIC D 16 40 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR Purchase Samples TMP513AIDR ACTIVE SOIC D 16 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR Request Free Samples (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com 20-Jul-2010 TAPE AND REEL INFORMATION *All dimensions are nominal Device TMP512AIDR Package Package Pins Type Drawing SOIC D 14 SPQ Reel Reel A0 Diameter Width (mm) (mm) W1 (mm) 2500 330.0 16.4 Pack Materials-Page 1 6.5 B0 (mm) K0 (mm) P1 (mm) 9.0 2.1 8.0 W Pin1 (mm) Quadrant 16.0 Q1 PACKAGE MATERIALS INFORMATION www.ti.com 20-Jul-2010 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) TMP512AIDR SOIC D 14 2500 346.0 346.0 33.0 Pack Materials-Page 2 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DLP® Products www.dlp.com Communications and Telecom www.ti.com/communications DSP dsp.ti.com Computers and Peripherals www.ti.com/computers Clocks and Timers www.ti.com/clocks Consumer Electronics www.ti.com/consumer-apps Interface interface.ti.com Energy www.ti.com/energy Logic logic.ti.com Industrial www.ti.com/industrial Power Mgmt power.ti.com Medical www.ti.com/medical Microcontrollers microcontroller.ti.com Security www.ti.com/security RFID www.ti-rfid.com Space, Avionics & Defense www.ti.com/space-avionics-defense RF/IF and ZigBee® Solutions www.ti.com/lprf Video and Imaging www.ti.com/video Wireless www.ti.com/wireless-apps Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2010, Texas Instruments Incorporated