LEM HTB100-P

Current Transducers HTB 50 .. 400-P
and HTB 50 .. 100-TP
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 50 .. 400 A
Electrical data
Primary nominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
50
100
200
300
400
VC
IC
Vd
R IS
VOUT
ROUT
RL
±150
±300
±500
±600
±600
Type
HTB 50-P, HTB 50-TP1)
HTB 100-P, HTB 100-TP1)
HTB 200-P
HTB 300-P
HTB 400-P
Supply voltage (±5 %)2)
Current consumption
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
Isolation resistance @ 500 VDC
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C
Output internal resistance
Load resistance
±12 .. ±15
<±15
2.5
>500
±4
100
≥10
V
mA
kV
MΩ
V
Ω
kΩ
Accuracy - Dynamic performance data
X
ε
L
VOE
VOH
VOT
TC ε G
tr
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 3 x IPN
Thermal drift of VOE
HTB 50-(T)P
HTB 100-(T)P..400-P
Thermal drift (% of reading)
Response time @ 90% of IP
Frequency bandwidth (-3 dB)3)
<±1
<±1
<±30
% of IPN
% of IPN
mV
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500V
• Low power consumption
• Wide power supply: ±12V to ±15V
• Primary bus bar option for 50A and
100A version for ease of connection
Advantages
• Small size and space saving
• Only one design for wide current
ratings range
<±1
% of IPN
<±2.0
mV/K
<±1.0
mV/K
<±0.1
%/K
<3
µs
DC .. 50 kHz
General data
TA
TS
m
Features
Ambient operating temperature
-20 .. +80
Ambient storage temperature
-25 .. +85
Mass (-TP version)
<30 (<36)
2 pins of Ø2mm diameter are available on transducer
for PCB soldering.
°C
°C
g
• High immunity to external
interference.
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Notes : EN 50178 approval pending
1)
-TP version is equipped with a primary bus bar.
2)
Operating at ±12V ≤ Vc < ±15V will reduce measuring range.
3)
Derating is needed to avoid excessive core heating at high frequency.
030529/7
LEM Components
www.lem.com
HTB 50 .. 400-P
Left view
Back view
Positive Current Flow
39
9 +/-1
1.5
19.5
34
d1
6
14 MAX.
3.5
4321
4-0.635x0.635
24.5
Secondary Pin Identification
5.5
3-P=2.5
10
Bottom view
1
2
3
4
7
11
3
6 +/-1
2-d2
Mounting Pins
3
19
+Vc
-Vc
Output
0V
HTB 50 .. 100-TP
39
14 MAX.
Left view
10
1.5
1.5
3.5
4 321
4-0.635x0.635
3.5
1.5
17
34
Back view
1.5
Positive Current Flow
3-P=2.5 10.5 3 3
3.25
6-1.5x1.5
3
11
14
2
6.5
3
Secondary Pin Identification
1
2
3
4
+Vc
-Vc
Output
0V
Bottom view
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.