LEM HAIS100-P

Current Transducer HAIS 50..400-P
and HAIS 50..100-TP
IPN = 50 .. 400 A
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
All Data are given with a R L = 10 kΩ
Electrical data
Primary nominal
current rms
IPN (A)
50
100
150
200
400
VOUT
VREF
RL
ROUT
CL
VC
IC
Primary current,
measuring range
IPM (A)
±
±
±
±
±
150
300
450
600
600
Type
RoHS since
date code
HAIS 50-P, HAIS 50-TP1)
HAIS 100-P, HAIS 100-TP1)
HAIS 150-P
HAIS 200-P
HAIS 400-P
Output voltage (Analog) @ IP
IP = 0
Reference voltage 2) - Output voltage
VREF Output impedance
VREF Load impedance
Load resistance
Output internal resistance
Capacitive loading
Supply voltage (± 5 %)
Current consumption @ VC = 5 V
45231, 46272
45231, 46012
46172
45231
planned
VREF ± (0.625·IP/IPN) V
VREF ± 0.025
V
2.5 ± 0.025
V
typ. 200
Ω
≥ 200
kΩ
≥2
kΩ
< 10
Ω
<1
µF
5
V
22
mA
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation test voltage 2500V
• Low power consumption
• Single power supply +5V
• Fixed offset & gain
• Bus bar version available for 50A and
100A ratings.
• Insulated plastic case recognized
according to UL94-V0.
Advantages
• Small size and space saving
• Only one design for wide current
ratings range
• High immunity to external
Accuracy - Dynamic performance data
X
ε
L
TCVOE
TCVREF
TCVOUT / VREF
TCVOUT
VOM
t ra
tr
di/dt
Vno
BW
Accuracy 3) @ IPN , TA = 25°C
Linearity error 0 .. 3 x IPN
Temperature coefficient of VOE @ IP = 0
Temperature coefficient of VREF
Temperature coefficient of VOUT / VREF @ IP = 0
Temperature coefficient of VOUT
Magnetic offset voltage @ IP = 0,
after an overload of 3 x IPN DC
Reaction time @ 10 % of IPN
Response time to 90 % of IPN step
di/dt accurately followed
Output voltage noise (DC ..10 kHz)
(DC .. 1 MHz)
Frequency bandwidth (-3 dB) 4)
≤±
≤±
≤±
≤±
≤±
1
0.5
0.3
0.01
0.2
% of IPN
% of IPN
mV/K
%/K
mV/K
≤ ± 0.05% of reading/K
< ± 0.4
<3
<5
> 100
< 15
< 40
DC .. 50
% of IPN
µs
µs
A/µs
mVpp
mVpp
kHz
interference.
• VREF. IN/OUT
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Application Domain
Notes : 1) -TP version is equipped with a primary bus bar.
2)
It is possible to overdrive VREF with an external reference voltage
between 2 - 2.8 V providing its ability to sink or source approximately
2.5 mA.
3)
Excluding offset and hysteresis.
4)
Small signal only to avoid excessive heatings of the magnetic core.
• Industrial
Page 1/3
061018/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Current Transducer HAIS 50..400-P and HAIS 50..100-TP
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass (in brackets : TP version)
Standards
- 40 .. + 85
°C
- 40 .. + 85
°C
20 (30)
g
EN 50178: 1997
Isolation characteristics
Vb
Vb
Vd
Ve
Vw
dCp
dCl
CTI
Rated isolation voltage rms
with IEC 61010-1 standards and following conditions
- Single insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
Rated isolation voltage rms
with EN 50178 standards and following conditions
- Reinforced insulation
- Over voltage category III
- Pollution degree 2
- Heterogeneous field
Rms voltage for AC isolation test, 50 Hz, 1 min
Partial discharge extinction voltage rms @ 10pC
HAIS 50..400-P
HAIS 50..100-TP
Impulse withstand voltage 1.2/50 µs
Creepage distance
Clearance distance
Comparative tracking index (Group I)
300
V rms
600
V rms
2.5
>1
> 1.4
8
>8
>8
> 600
kV
kV
kV
kV
mm
mm
If insulated cable is used for the primary circuit, the
voltage category could be improved with the following table :
Cable insulation (primary)
Category
HAR 03
450V CAT III
HAR 05
550V CAT III
HAR 07
650V CAT III
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the following
manufacturer's operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
061018/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HAIS 50..400-P and HAIS 50..100-TP (in mm. 1 mm = 0.0394 inch)
HAIS 50..100-TP
HAIS 50..400-P
Front view
Front view
Right view
33
15
0.5
3.5
3
3
3.5
0.5
16
29
29
8
33
1.5
2-D1.0
2-D1.0
6
4-0.25x0.45
Bottom view
1.5
Bottom view
10
3-P1.8
6
14.5
Terminal Pin Identification
25.9
19.9
5
4
4.3
6
11
1
11
6.5
5
4
6
4.3
14.5
1.5
1.5
11
6.5
14
1
3-P1.8
11
Recommended
connection
Required Connection
Circuitcircuit
1...+5V
2...0V
3...OUTPUT
4...Vref. (IN/OUT)
5...Core Earth (*)
6...NC.
1
2
3
4
47nF
4.7nF
47nF
+5V
0V
OUTPUT
Vref. (IN/OUT)
5
Recommended PCB hole
Pin 1-4 : 0.7 ±0.1mm
Pin 5-6 : 1.5 ±0.1mm
Primary bus bar : 2.3 ±0.1mm
General tolerance : ±0.2mm
Unit : mm
Operation Principle
+Vc
Vout
Vref.(IN/OUT)
Ip
0V
(*)
should be connected to 0V of Power Supply for better dv/dt immunity.
Arrow indicates positive current direction.
Page 3/3
061018/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com