NEC RD9.1MW

DATA SHEET
ZENER DIODES
RD2.0MW to RD39MW
ZENER DIODES
200 mW 3-PIN MINI MOLD
DESCRIPTION
PACKAGE DIMENSIONS
Type RD2.0MW to RD39MW Series are 3-PIN Mini Mold Package
(Unit: mm)
zener diodes possessing allowable power dissipation of 200 mW.
2.8 ± 0.2
+0.1
VZ; Applied E24 standard
0.65 +0.1
–0.15
1.5
1
3
MAXIMUM RATINGS (TA = 25°C)
+0.1
Surge absorber, ESD Protect circuit, etc.
2
0.4 –0.05
Circuits for Constant Voltage, Constant Current, Wavefore clipper,
0.95
APPLICATIONS
0.95
Surge absorber on either side
2.9 ± 0.2
•
•
0.4 –0.05
FEATURES
Tj
150°C
Storage Temperature
Tstg
–55 to +150°C
Peak Reverse Power
PRSM
85 W (t = 10 µs)
Forward Current
IF
100 mA
0.16 +0.1
–0.06
Junction Temperature
0 to 0.1
200 mW
1.1 to 1.4
P
0.3
Marking
Power Dissipation
1 . Cathode : K1
2 . Cathode : K2 SC-59 (EIAJ)
3 . Anode : A
K2
2
A
3
K1
1
The information in this document is subject to change without notice. Before using this document, please
confirm that this is the latest version.
Not all devices/types available in every country. Please check with local NEC representative for availability
and additional information.
Document No. D10247EJ5V0DS00 (5th edition)
Date Published June 2000 N CP(K)
Printed in Japan
©
1993
RD2.0MW to RD39MW
ELECTRICAL CHARACTERISTICS (TA = 25 ± 2°C)
Type
Number
Dynamic
Impedance
ZZ (Ω)Note 2
Zener Voltage
VZ (V) Note 1
Class
MIN.
MAX.
Iz (mA)
MAX.
Iz (mA)
MAX.
VR(V)
RD2.0MW
B
1.90
2.20
5
100
5
120
0.5
RD2.2MW
B
2.10
2.40
5
100
5
120
0.7
RD2.4MW
B
2.30
2.60
5
100
5
120
1.0
RD2.7MW
B
2.50
2.90
5
110
5
120
1.0
RD3.0MW
B
2.80
3.20
5
120
5
50
1.0
RD3.3MW
B
3.10
3.50
5
130
5
20
1.0
RD3.6MW
B
3.40
3.80
5
130
5
10
1.0
RD3.9MW
B
3.70
4.10
5
130
5
10
1.0
RD4.3MW
B
4.01
4.48
5
130
5
10
1.0
RD4.7MW
B
4.42
4.90
5
130
5
10
1.0
RD5.1MW
B
4.84
5.37
5
130
5
5
1.0
RD5.6MW
B
5.31
5.92
5
80
5
5
1.5
RD6.2MW
B
5.86
6.53
5
50
5
2
2.5
RD6.8MW
B
6.47
7.14
5
30
5
2
3.5
RD7.5MW
B
7.06
7.84
5
30
5
2
4.0
RD8.2MW
B
7.76
8.64
5
30
5
2
5.0
RD9.1MW
B
8.56
9.55
5
30
5
2
6.0
RD10MW
B
9.45
10.55
5
30
5
2
7.0
RD11MW
B
10.44
11.56
5
30
5
2
8.0
RD12MW
B
11.42
12.60
5
35
5
2
9.0
RD13MW
B
12.47
13.96
5
35
5
2
10
RD15MW
B
13.84
15.52
5
40
5
2
11
RD16MW
B
15.37
17.09
5
40
5
2
12
RD18MW
B
16.94
19.03
5
45
5
2
13
RD20MW
B
18.86
21.08
5
50
5
2
15
RD22MW
B
20.88
23.17
5
55
5
2
17
RD24MW
B
22.93
25.57
5
60
5
2
19
RD27MW
B
25.10
28.90
2
70
2
2
21
RD30MW
B
28.00
32.00
2
80
2
2
23
RD33MW
B
31.00
35.00
2
80
2
2
25
RD36MW
B
34.00
38.00
2
90
2
2
27
RD39MW
B
37.00
41.00
2
100
2
2
30
Note 1. Tested with pulse (40 ms)
2. Zz is measured at Iz given a very small A.C. signal
2
Reverse Current
IR (µA)
Data Sheet D10247EJ5V0DS00
RD2.0MW to RD39MW
Type
Number
Class
Zener Voltage
+Forward Voltage
(VZ + VF) (V)
MIN.
MAX.
I Z (mA)
Zener Voltage
+ Forward Voltage
∆(V + VF) (V)
MAX.
IZ (mA)
RD2.0MW
B
2.54
3.04
5
0.35
5
RD2.2MW
B
2.74
3.24
5
0.35
5
RD2.4MW
B
2.97
3.47
5
0.35
5
RD2.7MW
B
3.17
3.77
5
0.35
5
RD3.0MW
B
3.47
4.07
5
0.35
5
RD3.3MW
B
3.77
4.37
5
0.35
5
RD3.6MW
B
4.07
4.67
5
0.35
5
RD3.9MW
B
4.37
4.97
5
0.35
5
RD4.3MW
B
4.68
5.35
5
0.35
5
RD4.7MW
B
5.09
5.77
5
0.35
5
RD5.1MW
B
5.51
6.24
5
0.35
5
RD5.6MW
B
5.98
6.79
5
0.35
5
RD6.2MW
B
6.53
7.40
5
0.35
5
RD6.8MW
B
7.14
8.01
5
0.35
5
RD7.5MW
B
7.73
8.71
5
0.35
5
RD8.2MW
B
8.07
9.87
5
0.35
5
RD9.1MW
B
8.87
10.87
5
0.35
5
RD10MW
B
10.12
11.42
5
0.70
5
RD11MW
B
11.11
12.43
5
0.70
5
RD12MW
B
12.09
13.47
5
0.70
5
RD13MW
B
13.14
14.83
5
0.90
5
RD15MW
B
14.51
16.37
5
0.90
5
RD16MW
B
16.04
17.96
5
0.90
5
RD18MW
B
17.61
19.90
5
1.20
5
RD20MW
B
19.53
21.95
5
1.20
5
RD22MW
B
21.55
24.04
5
1.20
5
RD24MW
B
23.60
26.44
5
1.20
5
RD27MW
B
25.73
29.73
2
1.70
2
RD30MW
B
28.63
32.83
2
1.70
2
RD33MW
B
31.63
35.83
2
1.70
2
RD36MW
B
34.63
38.83
2
1.70
2
RD39MW
B
37.63
41.83
2
1.70
2
Data Sheet D10247EJ5V0DS00
Forward Voltage
A–K1
VF (V) A–K2
MAX.
IF (mA)
1.2
100
3
RD2.0MW to RD39MW
TYPICAL CHARACTERISTICS (TA = 25°C)
Fig. 1 P - TA RATING
P - Power Dissipation - mW
250
200
150
100
50
25
50
75
100
125
TA - Ambient Temperature - °C
0
150
Fig. 2 IZ - VZ CHARACTERISTICS (a to e)
IZ - Zener Current - A
10 m
RD2.0MW
RD2.2MW
RD5.6MW
RD3.3MW
100 µ
10 µ
1µ
RD5.1MW
RD4.7MW
RD3.6MW RD4.3MW
1n
1
2
1m
RD7.5MW
RD15MW
10 µ
1µ
1n
9
10
0
7
10 µ
1µ
9
10 11 12 13
VZ - Zener Voltage - V
(b)
14
15
RD22MW RD24MW RD27MW
RD30MW
10 m
100 µ
8
100 m
RD18MW
RD20MW
IZ - Zener Current - A
RD16MW
8
1m
1m
100 µ
10 µ
1µ
100 n
100 n
10 n
10 n
1n
11
RD13MW
100 µ
10 n
RD6.8MW
3
4
5
6
7
VZ - Zener Voltage - V
(a)
100 m
10 m
RD12MW
100 n
RD3.3MW
0
RD11MW
RD10MW
10 m
RD2.7MW
10 n
IZ - Zener Current - A
100 m
RD2.4MW
RD3.0MW
1m
100 n
4
RD8.2MW
RD6.2MW
RD9.1MW
IZ - Zener Current - A
100 m
1n
12
13
14 15 16 17 18
VZ - Zener Voltage - V
(c)
19
20
Data Sheet D10247EJ5V0DS00
0 15
20
22
24
25
VZ - Zener Voltage - V
(d)
28
30
RD2.0MW to RD39MW
IZ - Zener Current - A
100 m
RD32MW RD36MW
10 m
1m
RD39MW
100 µ
10 µ
1µ
100 n
10 n
1n
0 15
30
35
40
VZ - Zener Voltage - V
(e)
Fig. 4 ZZ - IZ CHARACTERISTICS
40
32
%/°C
0.08
0.06
24
16
0.04
mV/°C
0.02
8
0
0
–0.02
–8
–0.04
–16
–0.06
–24
4
8
12 16 20 24 28 32
VZ - Zener Voltage - V
36 40
1000
TYP.
ZZ - Zener Impedance - Ω
TYP.
0.1
γZ - VZ Temperature Coefficient - mV/°C
γZ - VZ Temperature Coefficient - %/°C
Fig. 3 γ Z - VZ CHARACTERISTICS
RD5.6MW
RD39MW
100 RD24MW
RD2.0MW
RD2.4MW
RD3.0MW
RD3.9MW
RD4.7MW
RD20MW
RD5.1MW
RD15MW
10
RD10MW
RD7.5MW
1
0.1
Data Sheet D10247EJ5V0DS00
1
10
IZ - Zener Current - mA
100
5
RD2.0MW to RD39MW
Fig. 5 TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS
Zth – Transient Thermal Impedance – °C/W
1000
625 °C/W
100
RD∗∗MW
10
1
0.1
1m
10 m
100 m
1
10
100
t – Time – s
Fig. 6 SURGE REVERSE POWER RATINGS
10000
PRSM – Surge Reverse Power – W
PRSM
TA = 25°C
Repetitive
100
RD∗∗MW
10
1
1µ
10 µ
100 µ
1m
t – Pulse Width – s
6
tT
1000
Data Sheet D10247EJ5V0DS00
10 m
100 m
RD2.0MW to RD39MW
[MEMO]
Data Sheet D10247EJ5V0DS00
7
RD2.0MW to RD39MW
[MEMO]
• The information in this document is subject to change without notice. Before using this document, please
confirm that this is the latest version.
• No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in
this document.
• NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property
rights of third parties by or arising from use of a device described herein or any other liability arising from use
of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other
intellectual property rights of NEC Corporation or others.
• Descriptions of circuits, software, and other related information in this document are provided for illustrative
purposes in semiconductor product operation and application examples. The incorporation of these circuits,
software, and information in the design of the customer's equipment shall be done under the full responsibility
of the customer. NEC Corporation assumes no responsibility for any losses incurred by the customer or third
parties arising from the use of these circuits, software, and information.
• While NEC Corporation has been making continuous effort to enhance the reliability of its semiconductor devices,
the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or
property arising from a defect in an NEC semiconductor device, customers must incorporate sufficient safety
measures in its design, such as redundancy, fire-containment, and anti-failure features.
• NEC devices are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a
customer designated “quality assurance program“ for a specific application. The recommended applications of
a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device
before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment,
audio and visual equipment, home electronic appliances, machine tools, personal electronic
equipment and industrial robots
Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically designed
for life support)
Specific: Aircraft, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc.
The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
they should contact an NEC sales representative in advance.
M7 98.8