DATA SHEET ZENER DIODES RD2.0MW to RD39MW ZENER DIODES 200 mW 3-PIN MINI MOLD DESCRIPTION PACKAGE DIMENSIONS Type RD2.0MW to RD39MW Series are 3-PIN Mini Mold Package (Unit: mm) zener diodes possessing allowable power dissipation of 200 mW. 2.8 ± 0.2 +0.1 VZ; Applied E24 standard 0.65 +0.1 –0.15 1.5 1 3 MAXIMUM RATINGS (TA = 25°C) +0.1 Surge absorber, ESD Protect circuit, etc. 2 0.4 –0.05 Circuits for Constant Voltage, Constant Current, Wavefore clipper, 0.95 APPLICATIONS 0.95 Surge absorber on either side 2.9 ± 0.2 • • 0.4 –0.05 FEATURES Tj 150°C Storage Temperature Tstg –55 to +150°C Peak Reverse Power PRSM 85 W (t = 10 µs) Forward Current IF 100 mA 0.16 +0.1 –0.06 Junction Temperature 0 to 0.1 200 mW 1.1 to 1.4 P 0.3 Marking Power Dissipation 1 . Cathode : K1 2 . Cathode : K2 SC-59 (EIAJ) 3 . Anode : A K2 2 A 3 K1 1 The information in this document is subject to change without notice. Before using this document, please confirm that this is the latest version. Not all devices/types available in every country. Please check with local NEC representative for availability and additional information. Document No. D10247EJ5V0DS00 (5th edition) Date Published June 2000 N CP(K) Printed in Japan © 1993 RD2.0MW to RD39MW ELECTRICAL CHARACTERISTICS (TA = 25 ± 2°C) Type Number Dynamic Impedance ZZ (Ω)Note 2 Zener Voltage VZ (V) Note 1 Class MIN. MAX. Iz (mA) MAX. Iz (mA) MAX. VR(V) RD2.0MW B 1.90 2.20 5 100 5 120 0.5 RD2.2MW B 2.10 2.40 5 100 5 120 0.7 RD2.4MW B 2.30 2.60 5 100 5 120 1.0 RD2.7MW B 2.50 2.90 5 110 5 120 1.0 RD3.0MW B 2.80 3.20 5 120 5 50 1.0 RD3.3MW B 3.10 3.50 5 130 5 20 1.0 RD3.6MW B 3.40 3.80 5 130 5 10 1.0 RD3.9MW B 3.70 4.10 5 130 5 10 1.0 RD4.3MW B 4.01 4.48 5 130 5 10 1.0 RD4.7MW B 4.42 4.90 5 130 5 10 1.0 RD5.1MW B 4.84 5.37 5 130 5 5 1.0 RD5.6MW B 5.31 5.92 5 80 5 5 1.5 RD6.2MW B 5.86 6.53 5 50 5 2 2.5 RD6.8MW B 6.47 7.14 5 30 5 2 3.5 RD7.5MW B 7.06 7.84 5 30 5 2 4.0 RD8.2MW B 7.76 8.64 5 30 5 2 5.0 RD9.1MW B 8.56 9.55 5 30 5 2 6.0 RD10MW B 9.45 10.55 5 30 5 2 7.0 RD11MW B 10.44 11.56 5 30 5 2 8.0 RD12MW B 11.42 12.60 5 35 5 2 9.0 RD13MW B 12.47 13.96 5 35 5 2 10 RD15MW B 13.84 15.52 5 40 5 2 11 RD16MW B 15.37 17.09 5 40 5 2 12 RD18MW B 16.94 19.03 5 45 5 2 13 RD20MW B 18.86 21.08 5 50 5 2 15 RD22MW B 20.88 23.17 5 55 5 2 17 RD24MW B 22.93 25.57 5 60 5 2 19 RD27MW B 25.10 28.90 2 70 2 2 21 RD30MW B 28.00 32.00 2 80 2 2 23 RD33MW B 31.00 35.00 2 80 2 2 25 RD36MW B 34.00 38.00 2 90 2 2 27 RD39MW B 37.00 41.00 2 100 2 2 30 Note 1. Tested with pulse (40 ms) 2. Zz is measured at Iz given a very small A.C. signal 2 Reverse Current IR (µA) Data Sheet D10247EJ5V0DS00 RD2.0MW to RD39MW Type Number Class Zener Voltage +Forward Voltage (VZ + VF) (V) MIN. MAX. I Z (mA) Zener Voltage + Forward Voltage ∆(V + VF) (V) MAX. IZ (mA) RD2.0MW B 2.54 3.04 5 0.35 5 RD2.2MW B 2.74 3.24 5 0.35 5 RD2.4MW B 2.97 3.47 5 0.35 5 RD2.7MW B 3.17 3.77 5 0.35 5 RD3.0MW B 3.47 4.07 5 0.35 5 RD3.3MW B 3.77 4.37 5 0.35 5 RD3.6MW B 4.07 4.67 5 0.35 5 RD3.9MW B 4.37 4.97 5 0.35 5 RD4.3MW B 4.68 5.35 5 0.35 5 RD4.7MW B 5.09 5.77 5 0.35 5 RD5.1MW B 5.51 6.24 5 0.35 5 RD5.6MW B 5.98 6.79 5 0.35 5 RD6.2MW B 6.53 7.40 5 0.35 5 RD6.8MW B 7.14 8.01 5 0.35 5 RD7.5MW B 7.73 8.71 5 0.35 5 RD8.2MW B 8.07 9.87 5 0.35 5 RD9.1MW B 8.87 10.87 5 0.35 5 RD10MW B 10.12 11.42 5 0.70 5 RD11MW B 11.11 12.43 5 0.70 5 RD12MW B 12.09 13.47 5 0.70 5 RD13MW B 13.14 14.83 5 0.90 5 RD15MW B 14.51 16.37 5 0.90 5 RD16MW B 16.04 17.96 5 0.90 5 RD18MW B 17.61 19.90 5 1.20 5 RD20MW B 19.53 21.95 5 1.20 5 RD22MW B 21.55 24.04 5 1.20 5 RD24MW B 23.60 26.44 5 1.20 5 RD27MW B 25.73 29.73 2 1.70 2 RD30MW B 28.63 32.83 2 1.70 2 RD33MW B 31.63 35.83 2 1.70 2 RD36MW B 34.63 38.83 2 1.70 2 RD39MW B 37.63 41.83 2 1.70 2 Data Sheet D10247EJ5V0DS00 Forward Voltage A–K1 VF (V) A–K2 MAX. IF (mA) 1.2 100 3 RD2.0MW to RD39MW TYPICAL CHARACTERISTICS (TA = 25°C) Fig. 1 P - TA RATING P - Power Dissipation - mW 250 200 150 100 50 25 50 75 100 125 TA - Ambient Temperature - °C 0 150 Fig. 2 IZ - VZ CHARACTERISTICS (a to e) IZ - Zener Current - A 10 m RD2.0MW RD2.2MW RD5.6MW RD3.3MW 100 µ 10 µ 1µ RD5.1MW RD4.7MW RD3.6MW RD4.3MW 1n 1 2 1m RD7.5MW RD15MW 10 µ 1µ 1n 9 10 0 7 10 µ 1µ 9 10 11 12 13 VZ - Zener Voltage - V (b) 14 15 RD22MW RD24MW RD27MW RD30MW 10 m 100 µ 8 100 m RD18MW RD20MW IZ - Zener Current - A RD16MW 8 1m 1m 100 µ 10 µ 1µ 100 n 100 n 10 n 10 n 1n 11 RD13MW 100 µ 10 n RD6.8MW 3 4 5 6 7 VZ - Zener Voltage - V (a) 100 m 10 m RD12MW 100 n RD3.3MW 0 RD11MW RD10MW 10 m RD2.7MW 10 n IZ - Zener Current - A 100 m RD2.4MW RD3.0MW 1m 100 n 4 RD8.2MW RD6.2MW RD9.1MW IZ - Zener Current - A 100 m 1n 12 13 14 15 16 17 18 VZ - Zener Voltage - V (c) 19 20 Data Sheet D10247EJ5V0DS00 0 15 20 22 24 25 VZ - Zener Voltage - V (d) 28 30 RD2.0MW to RD39MW IZ - Zener Current - A 100 m RD32MW RD36MW 10 m 1m RD39MW 100 µ 10 µ 1µ 100 n 10 n 1n 0 15 30 35 40 VZ - Zener Voltage - V (e) Fig. 4 ZZ - IZ CHARACTERISTICS 40 32 %/°C 0.08 0.06 24 16 0.04 mV/°C 0.02 8 0 0 –0.02 –8 –0.04 –16 –0.06 –24 4 8 12 16 20 24 28 32 VZ - Zener Voltage - V 36 40 1000 TYP. ZZ - Zener Impedance - Ω TYP. 0.1 γZ - VZ Temperature Coefficient - mV/°C γZ - VZ Temperature Coefficient - %/°C Fig. 3 γ Z - VZ CHARACTERISTICS RD5.6MW RD39MW 100 RD24MW RD2.0MW RD2.4MW RD3.0MW RD3.9MW RD4.7MW RD20MW RD5.1MW RD15MW 10 RD10MW RD7.5MW 1 0.1 Data Sheet D10247EJ5V0DS00 1 10 IZ - Zener Current - mA 100 5 RD2.0MW to RD39MW Fig. 5 TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS Zth – Transient Thermal Impedance – °C/W 1000 625 °C/W 100 RD∗∗MW 10 1 0.1 1m 10 m 100 m 1 10 100 t – Time – s Fig. 6 SURGE REVERSE POWER RATINGS 10000 PRSM – Surge Reverse Power – W PRSM TA = 25°C Repetitive 100 RD∗∗MW 10 1 1µ 10 µ 100 µ 1m t – Pulse Width – s 6 tT 1000 Data Sheet D10247EJ5V0DS00 10 m 100 m RD2.0MW to RD39MW [MEMO] Data Sheet D10247EJ5V0DS00 7 RD2.0MW to RD39MW [MEMO] • The information in this document is subject to change without notice. Before using this document, please confirm that this is the latest version. • No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in this document. • NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from use of a device described herein or any other liability arising from use of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of NEC Corporation or others. • Descriptions of circuits, software, and other related information in this document are provided for illustrative purposes in semiconductor product operation and application examples. The incorporation of these circuits, software, and information in the design of the customer's equipment shall be done under the full responsibility of the customer. NEC Corporation assumes no responsibility for any losses incurred by the customer or third parties arising from the use of these circuits, software, and information. • While NEC Corporation has been making continuous effort to enhance the reliability of its semiconductor devices, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or property arising from a defect in an NEC semiconductor device, customers must incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and anti-failure features. • NEC devices are classified into the following three quality grades: "Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a customer designated “quality assurance program“ for a specific application. The recommended applications of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device before using it in a particular application. Standard: Computers, office equipment, communications equipment, test and measurement equipment, audio and visual equipment, home electronic appliances, machine tools, personal electronic equipment and industrial robots Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster systems, anti-crime systems, safety equipment and medical equipment (not specifically designed for life support) Specific: Aircraft, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those specified for Standard quality grade, they should contact an NEC sales representative in advance. M7 98.8