LT1085LCC4
MILITARY VERSION
MECHANICAL DATA
Dimensions in mm (inches)
CERAMIC SURFACE MOUNT
LOW DROPOUT POSITIVE ADJUSTABLE
VOLTAGE REGULATOR
FOR HI-REL APPLICATIONS
9.14 (0.360)
8.64 (0.340)
1.27 (0.050)
1.07 (0.040)
≈ 2.16 (0.085)
12 13 14 15 16
FEATURES
• Ceramic Surface Mount Hermetic Package
• Low Dropout Performance
• Output Current 3A
• Line Regulation 0.015% / V Typical.
• Load Regulation 0.1% Typical.
• Full Temperature Range (–55 to +150°C)
1.39 (0.055)
1.02 (0.040)
7.62 (0.300)
7.12 (0.280)
11
17
10
18
9
1
8
2
7
6
5
1.39 (0.055)
1.15 (0.045)
4
BLOCK DIAGRAM
VIN
0.76 (0.030)
0.51 (0.020)
0.33 (0.013)
Rad.
0.08 (0.003)
3
1.65 (0.065)
1.40 (0.055)
0.43 (0.017)
0.18 (0.007 Rad.
THERMAL
LIMIT
LCC4
Pads 5,4 = adjust
Pads 6,7,8,9,10,11,13 = Vin
Pads 1,2,15,16,17,18 = Vout
ABSOLUTE MAXIMUM RATINGS
VI-O
Input–Output Differential Voltage
PD
Power Dissipation
VIN
Operating Input Voltage
TJ
Operating Junction Temperature Range
TSTG
Storage Temperature Range
qJC
Thermal Resistance (junction to case)
VADJ
VOUT
(Tcase = 25°C unless otherwise stated)
30V
Internally limited
25V
Control
–55 to 150°C
Power
–55 to 200°C
–65 to 150°C
13°C/W
* Although the devices’ maximum operating voltage is limited to 25V the devices are guaranteed to withstand transient
input voltages up to 30V. For input voltages greater than the maximum operating input voltage, some degradation of
specifications will occur.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
Prelim. 8/00
LT1085LCC4
MILITARY VERSION
DESCRIPTION
The LT1085 is designed to provide 3A with higher efficiency than currently available devices. All internal circuitry is
designed to operate down to 1V input to output differential and the dropout voltage is fully specified as a function of load
current. Dropout is guaranteed at a maximum of 1.5V at maximum output current, decreasing at lower load currents. Onchip trimming adjusts the reference output voltage to 1%. Current limit is also trimmed, minimising the stress on both the
regulator and power source circuitry under overload conditions.
ELECTRICAL CHARACTERISTICS (Pre Irradiation)
Parameter
Test Conditions
VIN – VOUT = 3V
VREF
Reference Voltage
(TJ = 25°C unless otherwise stated)
IO = 10mA
VIN – VOUT = 1.5 to 15V IO = 10mA to 3A
TJ = –55 to 125°C
REG(LINE)
Line Regulation
IO = 10mA
Min.
Typ.
Max. Unit
1.238
1.250
1.252
1.225
1.25
1.270
0.015
0.2
(VIN–VOUT) = 1.5 to 15V
TJ = –55 to 125°C
%
IO = 10mA (VIN–VOUT) = 15 to 30V
0.5
TJ = –55 to 125°C
REG(LOAD) Load Regulation
VD
0.3
0.2
0.4
1.3
1.5
Dropout Voltage
DVREF = 1%
See note 3
IOUT = 3A
TJ = –55 to 125°C
VIN – VOUT = 5V
TJ = –55 to 125°C
3.2
4
VIN – VOUT = 25V
TJ = –55 to 125°C
0.2
0.5
VIN – VOUT = 5V
TJ = –55 to 125°C
TP = 30ms
f = 120Hz
TA = 25°C
VIN – VOUT = 3V
IO = 3A
CADJ = 25mF
IQ
Quiescent Current
Minimum Load Current 4
REG(THERM) Thermal Regulation
RA
Ripple Rejection
IPIN
Adjust Pin Current
DIPIN
Adjust Pin Current Change
TS
Temperature Stability
TJ = –55 to 125°C
0.1
IO = 10mA to 3A
Current Limit
VN
VIN – VOUT = 3V
See notes 1,2
ICL
TJ = –55 to 125°C
VIN – VOUT = 1.5 to 15V
IO = 10mA to 3A
TJ = –55 to 125°C
Long Term Stability
TJ = –55 to 125°C
TA = 125°C
T = 1000 Hrs
RMS Output Noise
f = 10Hz to 10kHz
TA = 25°C
V
60
%
V
A
5
10
mA
0.004
0.02
%/W
dB
75
55
120
mA
0.2
5
mA
0.5
%
0.3
%
0.003
%
Notes:
1 Load and line regulation are measured at a constant junction temperature by low duty cycle pulse testing.
2 Power dissipation is determined by the input - output differential and the output current. Guaranteed maximum power
2 dissipation will not be available over the full input - output voltage range.
3 Dropout voltage is specified over the full output current range of the device.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: [email protected]
Website: http://www.semelab.co.uk
Prelim. 8/00