SUPERTEX SR036DB1

SR036DB1
Inductorless Switching Power Supply
Specifications
Introduction
The Supertex SR036 is an inductorless, dual output off-line
regulator intended for 120/240VAC line operation. The
operating principle is to activate a pass element between
line and load only when the input voltage is lower than a
certain value. Thus conduction only occurs with a low
voltage drop across the pass element, resulting in more
efficient operation compared to a standard linear regulator.
24VAC to 264VAC
40Hz to 100Hz
AC Input
Output Voltages
VUNREG
VREG
Output Current
IUNREG + IREG
The SR036DB1 demo board contains all the circuitry
needed to supply a low-current (<40mA) load. Included are
input protection circuitry, a full wave bridge rectifier, a pass
element, and output capacitors.
18V±20%
3.3V ±10%
40mA @ 120VAC
30mA @ 240VAC
Efficiency
ACIN=120VAC 60Hz, IU=40mA, IR=0mA
40% typ
Board Layout and Connections
Q1
D1
Z1
IC1
ACIN
F1
C1
C2
GND
WARNING!!!
Do not connect to scope ground or to the ground of other
earth-grounded instruments. Doing so will short the AC line,
resulting in damage to the circuit and/or instrument. Either
use an isolation transformer on the AC line, use a differential
probe, or use a floating, battery-powered instrument to make
measurements.
VREG
VUNREG
WARNING!!!
No galvanic isolation. Dangerous voltages are
present when connected to the AC mains.
ACIN
VUNREG
Connect to the AC line. Neutral to top, hot to bottom.
The unregulated output. Nominal output voltage is 18 volts.
This output will have a certain amount of 120Hz ripple,
depending on load.
GND
Circuit common.
Note that since galvanic isolation is not provided, connecting
this point to an earth-grounded instrument (such as an
oscilloscope) will short the AC line, resulting in circuit and/or
instrument damage.
Also note that GND may be at a higher potential with respect
to earth ground, even if the AC is switched off. Use caution!
Do not connect to earth-ground.
Do not connect to earth-grounded loads.
VREG
The regulated output. 5V nominal output voltage.
Do not connect to earth-grounded loads.
Fuse
The AC input is fused to protect against overloads. It should
be replaced with a 125mA, 250V standard 3AG fuse.
16APR02
1
SR036DB1
Inductorless Switching Power Supply
SR036 Circuit
F1
125mA
D1
Q1
VN2460N8
ACIN
Z1
P6KE400CA
VUNREG
C1
220µF
IC1
VREG
SR036
C2
1µF
Parts List
Desig
Description
Part Number
F1
Fuse, 3AG, 125mA, 250V
Z1
Transient voltage suppressor, 400V
D1
Diode bridge, 1A, 600V
IC1
HV Supply Controller
Supertex SR036SG
Q1
MOSFET, 600V N-channel
Supertex VN2460N8
C1
Capacitor, alum, 220µF, 35V
C2
Capacitor, cer, 1µF, 16V
P6KE400CA
Modifications
The SR036DB1 may be modified to provide higher output current. Remove Q1 and replace with a D-Pak N-channel MOSFET with
a voltage rating appropriate for the input voltage. The on resistance of the replacement FET is not as important as the gate
threshold voltage – the lower the threshold voltage, the more efficient the converter.
To reduce ripple at the higher output current, C1 may be replaced with a higher value capacitor.
16APR02
2