1~4 Output Medical Type 120W Medical series Features Universal AC input / Full range Low leakage current <180 A Protections: Short circuit / Overload / Over voltage UL60601-1 medical safety approved With power good and fail signal output (Optional) 100% full load burn-in test Fixed switching frequency at 45KHz 3 years warranty EN60601-1 IEC60601-1 Specification AC INPUT VOLTAGE 90~264 VAC, 47~440Hz / 127~370VDC. TEMP. COEFFICIENT 0.04%/ on all outputs at full load between 0~50 AC INPUT CURRENT (Typ.) Maximum input current 2.9A at 115VAC, 60Hz or 1.7A at 230VAC, 60Hz with 100% output load. VIBRATION 2G of acceleration, vibrating frequency adjust from 10Hz ~500Hz within a 10-minute cycle. 6 testing cycles (60 minutes) each along X, Y, Z axes. INRUSH CURRENT (Typ.) Inrush current is less than 22A at 115VAC or less than 45A at 230VAC under cold start conditions. Limiting provided by internal thermistors. SAFETY STANDARDS Medical : UL60601-1, TUV EN60601-1, IEC60601-1 approved Commercial : Also design refer to UL60950-1, TUV EN60950-1 SETUP, RISE TIME MPS-120: 800ms, 20ms / 230VAC at full load 2000ms, 50ms / 115VAC at full load MPD,T,Q-120:500ms, 20ms / 230VAC at full load 1200ms, 50ms / 115VAC at full load HOLD-UP TIME (Typ.) 80ms / 230VAC at full load 14ms / 115VAC at full load DC OUTPUT ADJ. RANGE DC output voltage (or Ch1 of multiple output models) can be adjusted between -5%~+10% rated output voltage by potential meter. OVERLOAD PROTECTION Fully protected against short circuit and output overload. The hiccup type protection will be activated at 110~150% (For MPD,T,Q-120),120~160%(For MPS-120) rated load and recovers automatically after fault condition is removed. OVER VOLTAGE PROTECTION Provided on output channel 1 only at 115%~135% rated output voltage. (120%~140% for MPS-120-15/24/48). Output will be shut down when this protection is activated. POWER GOOD / FAIL SIGNAL (OPTIONAL) TTL logic high for power good and TTL low for power fail. When the output voltage reaches 90% of rated value, a +5V TTL signal will be sent out with a 10~500ms delay; At least 1ms before the output voltage goes below 90% of the rated value, the TTL signal will be turned off. * MPS-120-3.3 does not have this optional function. WORKING TEMP. Whole series can operate from -20~70 to the derating curves. WITHSTAND VOLTAGE 4000VAC between input and output 1500VAC between input and F.G. 500VAC between output and F.G. ISOLATION RESISTANCE >100M Ohms for I/P-O/P, I/P-FG, O/P-FG by using 500VDC test voltage. EMI COMPLIANCE EMI Specifications Conducted & Radiation LEAKAGE CURRENT Leakage current is less than 180 A at 264VAC . Please refer of ambient temperature. Harmonic distortion Voltage flicker EMS COMPLIANCE EMS Specification ESD air ESD contact RF field susceptibility EFT(Electrical Fast Transient)/Burst Lightning/Surge Conducted RF susceptibility Magnetic field immunity Voltage dip, interruption Digital phone carrier immunity Compliance Level EN55011, Class B EN55022, Class B EN61000-3-2 EN61000-3-3 Compliance Level EN61000-4-2, Level 3, 8KV EN61000-4-2, Level 2, 4KV EN61000-4-3, Level 2, 3V/m Level 3, 10V/m EN61000-4-4, Level 2, 1KV/5KHz Level 3, 2KV/5KHz EN61000-4-5, Level 4, 2KV/Line-Line 4KV/Line-Earth EN61000-4-6, Level 2, 3Vrms/m Level 3, 10Vrms/m EN61000-4-8, Level 2, 3A/m Level 3, 10A/m EN61000-4-11,Compliance ENV50204, Level 2, 3V/m, 900MHz Level 3, 10A/m, 900MHz MTBF 262,100 hours min. at full load and 25 calculated per MIL-HDBK-217F. of ambient temperature, DIMENSION (L*W*H) 177.8x107.95x35.5mm or 7"x4.25"x1.4" PACKING 0.55Kg; 24pcs/14.5Kg/1.04CUFT WORKING HUMIDITY 20~90% RH non-condensing. STORAGE TEMP., HUMIDITY -40~+85 , 10~90% RH File Name:120W MEDICAL-SPEC 2008-03-25 120W Medical 1~4 Output Medical Type series Output Chart MODEL OUTPUT VOLTAGE RATED CURRENT MPS-120-3.3 3.3V 24A OUTPUT CURRENT RIPPLE & NOISE VOLTAGE PEAK LOAD (Max.) TOLERANCE WITH 25CFM FAN (Note 2) (Note 3) LINE LOAD REGULATION REGULATION EFFICIENCY MINIMUM LOAD CONVECTION (max.) WITH FAN (25CFM) (Note 4) 0A 16A 24A 26A 80mVp-p 3.0% 1.0% 3.0% 68% MPS-120-5 5V 22A 0A 14.7A 22A 26A 80mVp-p 3.0% 1.0% 3.0% 73% MPS-120-12 12V 10A 0A 6.7A 10A 11A 100mVp-p 2.0% 1.0% 2.0% 77% MPS-120-15 15V 8A 0A 5.3A 8A 8.8A 100mVp-p 2.0% 1.0% 2.0% 79% MPS-120-24 24V 5A 0A 3.3A 5A 5.5A 120mVp-p 2.0% 1.0% 2.0% 81% MPS-120-48 48V 2.5A 0A 1.7A 2.5A 2.8A 120mVp-p 2.0% 1.0% 2.0% 82% MPD-120A 5V 10A 2A 7.3A 10A 12A 80mVp-p 2.0% 0.5% 0.5% 12V 5A 0.5A 3.6A 5A 6A 120mVp-p 7.0% 2.0% 3.5% 5V 10A 2A 7A 10A 12A 80mVp-p 2.0% 0.5% 0.5% 24V 2.9A 0.3A 1.9A 2.9A 3.2A 250mVp-p 8.0% 2.0% 4.0% 5V 10A 2A 7.3A 10A 12A 80mVp-p 2.0% 0.5% 1.0% 12V 4.8A 0.4A 3.5A 4.8A 5.8A 120mVp-p +8,-6% 1.5% 3.5% -5V 0.6A 0A 0.3A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% 5V 10A 2A 7.3A 10A 12A 80mVp-p 2.0% 0.5% 1.0% 12V 4.4A 0.4A 3.2A 4.4A 5.3A 120mVp-p 6.0% 1.5% 3.5% -12V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% 5V 10A 2A 7A 10A 11A 80mVp-p 2.0% 0.5% 1.0% 15V 4A 0.4A 2.6A 4A 4.4A 150mVp-p +6,-7% 2.0% 3.5% -15V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% 5V 10A 2A 7.3A 10A 12A 80mVp-p 2.0% 0.5% 1.0% 24V 2.2A 0.4A 1.6A 2.2A 2.64A 300mVp-p +8,-6% 3.0% +4,-3% 12V 0.6A 0A 0.4A 0.6A 1A 120mVp-p 5.0% 0.5% 1.0% 5V 10A 2A 7.3A 10A 11A 80mVp-p 2.0% 0.5% 0.5% 12V 4.2A 0.5A 3.1A 4.2A 5A 120mVp-p 6.0% 1.5% 3.5% -5V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% -12V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% 5V 10A 2A 7.3A 10A 11A 80mVp-p 2.0% 0.5% 0.5% 15V 3.2A 0.5A 2.4A 3.2A 3.8A 150mVp-p +6,-7% 2.0% 3.5% -5V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% -15V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% 5V 10A 2A 7A 10A 11A 80mVp-p 2.0% 0.5% 0.5% 12V 1A 0.2A 0.7A 1A 1.1A 150mVp-p +8,-6% 2.0% 3.5% 24V 2.1A 0.3A 1.4A 2.1A 2.3A 300mVp-p 8.0% 2.0% 3.5% -12V 0.6A 0A 0.3A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% 5V 10A 2A 7.3A 10A 11A 80mVp-p 2.0% 0.5% 0.5% 12V 3A 0.5A 2.3A 3A 3.3A 120mVp-p 6.0% 2.0% 3.0% 15V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 8.0% 2.0% 3.0% 24V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% MPD-120B MPT-120A MPT-120B MPT-120C MPT-120D MPQ-120B MPQ-120C MPQ-120D MPQ-120E Notes : 75% 76% 72% 73% 72% 74% 71% 71% 74% 73% 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:120W MEDICAL-SPEC 2008-03-25 120W Medical 1~4 Output Medical Type Mechanical Specification series Unit:mm 177.8[7"] 165.1 [6.5"] CN1 95.25[3.75"] 13 12 11 10 9 8 7 6 5 4 3 2 1 CN2 107.95[4.25"] 5 4 3 2 1 10cm +V ADJ 4- 3.96[0.156"] 35.5 [1.4"] FAN 2 [0.078"] max. Pin Assignment AC Input Connector (CN1) : Molex 5273-05 or equivalent Pin No. 1 2,4 3 5 MPS-120 FG No Pin AC/N AC/L MPD-120 FG No Pin AC/N AC/L MPT-120 FG No Pin AC/N AC/L MPQ-120 FG No Pin AC/N AC/L Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent MPQ-120 V1 V1 V1 COM COM COM COM V2 V2 P.F.D. V3 No Pin V4 Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent DC Output Connector (CN2) : Molex 5273-13 or equivalent Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 MPS-120 +V +V +V -V -V -V -V +V +V P.F.D. NC No Pin NC MPD-120 V1 V1 V1 COM COM COM COM V2 V2 P.F.D. NC No Pin NC MPT-120 V1 V1 V1 COM COM COM COM V2 V2 P.F.D. V3 No Pin NC Derating Curve Static Characteristics 100 100 25CFM forced air cooling 90 80 40 Convection cooling 53W MPS-120-3.3 only 73.7W MPS-120-5 only 80W others 70 LOAD(%) LOAD (%) 60 80 MPS/D-120 MPT/Q-120 20 -20 0 10 20 30 40 50 55 60 AMBIENT TEMPERATURE ( ) 70 (HORIZONTAL) 60 50 40 90 100 115 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:120W MEDICAL-SPEC 2008-03-25