CHERRY 180-1001

BL Flat Packs
Big Little Digital Panel Meters
BL-176
BL-177
Backlighting Options
• Non-Backlit LCD Black on Grey Background
The MODUTEC BL Digital panel meter gives you all the
functionality you need with none of the extras you don’t
need. That means simplicity, easy readability, small
footprint, and a low cost.
• Ultra compact form factor with optional flat back design on BL-176 or BL-177
• Value priced
• Low power consumption
Applications
Telecommunications
Water Purification
Sewage Treatment
Flow
Process
Desalinization
DC Amps
DC Volts
The MODUTEC BL is easy-to-read and provides a variety of indicators
— all in a compact unit.
• 3 1/2 digit readout, full scale 1999 display
• 1/2" high digits on a high contrast LCD
• Auto-polarity (-) displayed
• “LO-BAT” indication on 9VDC power units
Ease of assembly is one of the BL’s most valuable benefits.
• 13 pin connection or solder pad connections
• Easy to install bezel mount, order 00-907062-002 for bezel kit
The BL offers a variety of flexible features to meet your unique
applications needs.
• User selectable decimal points
• Choice of 200mV, 2V or 20V input
• Choice of 9VDC, +5VDC; or 5 VDC power
[email protected] • www.jewellinstruments.com • 800 638-3771
BL Series Bezel, Window and Surface Mount Dimensional Drawings ( mm/in )
BL-176
2.5
D (4)
.098
30
1.18
NC
NC
D1
D2
D3
ROH
ROL
COM
RFH
RFL
V–
INLO
INHI
TST
V+
38.1
1.50
BP
E1
B1
G1
AB
60
2.36
6.1
.24
.76
.03
BL-177
60
2.36
6.1
.24
Note: Do not solder to pins.
30.5
1.20
8.4
.33
9.1
.36
2.54
0.10
V+
V–
NC
TST
COM
INLO
INHI
RFL
RFH
ROH
D3
D2
D1
2.5
D (4)
.098
30
1.18
Bezel Mounting (BL-176 and BL-177)
62.5
2.46
6.1
.24
2.5
R max (4)
.010
Panel Cutout
64.5
2.54
32.5
1.28
34.3
1.35
9
.35
How to Order
BL
-
BL Series Specifications
a
b
c
17 6
1
02
Terminals
a 6 = Solder Pads
7 = 13 Pins
DPM Power
b 1 = 9VDC
2 = +5v and -5VDC
3 = +5VDC
Input
c 01 = 200mVDC
02 = 2VDC
03 = 20VDC
Example: BL-176102 is a 9VDC (battery powered)
with solder pads, and a 2VDC input.
Female Connector for BL-177 order: 00-939033-091
Display
Digits: 3 1/2 digits, 7 segments Non-Backlit LCD (1999)
Digit Height: 0.5" (12.7 mm)
Polarity: Automatic (-) displayed
Decimal Point: Three positions, external selection
Overload: Three lower digits blank for readings greater than 1999 counts
Low Battery: “Low Bat” annunciator for <7.2V (9V power only)
Performance
Accuracy: (0.1% rdg + 2 count) with + 5 and 5V power
(0.1% rdg + 1 count) with 9V power
Conversion Rate: 2.5 per second
Common Mode Voltage Range: 1V maximum
Common Mode Rejection: > 86 db
Zero Adjust: Automatic
Tempco: 100 PPM/°C typical
Standard Analog Inputs
Full Scale Range: Choice 200mV, 2V, or 20V. Special Ranges and engineering units available
Configuration: True differential input and references
Ratiometric Operation: -176, -177
Protection: 250V DC or 150V RMS continuous 300V intermittent maximum
Bias Current: 1 pA typical, 10 pA maximum
[email protected] • www.jewellinstruments.com • 800 638-3771
850 Perimeter Road • Manchester, NH 03103 • USA
BL Series Specifications (continued)
Standard Power Options
9V Battery: 9V isolated, 7.2-12V at 150 uA
+5V and -5VDC: 5V 5% at 100 uA
+5V: 5V 5% at 3 mA
Connectors
13 connector pins, 0.025" square
BL-177
15 solder pads
Series BL-176
Environment
Operating2: 0°C to +50°C
Storage: -20°C to 70°C
2 Extended operating ranges available. Please consult factory.
Connector Pin Designations
V+, VNC:
TST:
COM:
IN HI, IN LO:
RFL, RFH:
ROH, ROL:
D1, D2, D3:
BP, E1, B1, G1, AB:
Positive & negative connections for power supply
Not Connected
Return for +5V power
Internal reference voltage return. Input common for 9V units
Signal inputs
Differential reference inputs
On board reference terminals. ROL on BL-176 only
Decimal point selection: Connect to V+ as follows:
D1=X.XXX
D2=XX.XX
D3=XXX.X
Can be used for underrange and overrange signal for external
auto ranging on the BL-176
Accessories and Options:
• Female connector for BL-100, -130, 177, -300, -330, -400, 430, -500, -530, -600, -630 series:
Order 939099-091
• For display hold function add suffix “-H” to catalog number
• For coated board and solid front cover add suffix “-MI” to catalog number
• For special OEM requirements, other input ranges, wider operating temperature, or other features,
contact factory.
[email protected] • www.jewellinstruments.com • 800 638-3771
850 Perimeter Road • Manchester, NH 03103 • USA