2.25 kW CW Helix TWT Series, 5.85 to 6.425 GHz, periodic-permanent, magnet focused, coaxial input, waveguide output, forced-air cooled. Custom configurations are also available. These variations in the performance and configuration include: mechanical configuration, electrical and RF connections, and dual-stage depressed collector. Features •2.25 kW •5.85 - 6.425 GHz • PPM Focusing • Coaxial Input • Waveguide Output •Any Mounting Position •Weight: 25 lbs. max •Forced-Air Cooled model Frequency (GHz) 5.85 - 6.425 VTC-6369C2 Power output (min) 2.25 kW TYPICAL OPERATING PARAMeters MAXIMUMMINIMUM Heater Voltage:6.6 6.0 Heater Surge Current: 5.0 --- Helix Voltage: 15.5 14.0 Helix Current: 25 --- Collector Voltage 1: 67% Ew 63% Ew Collector Current 1: 990 --- Cathode Current: --- --- Collector Voltage 2: 37% Ew 33% Ew Collector Current 2: 650 --- Cathode Warm-up Time:--- 3.0 Drive Power: --- --- Collector Temp: 150 --- Prime Power: --- --- Load VSWR: 1.7:1 --- Air Flow: 828 --- TYPICALUNITS --- Vdc ---A --- kVdc --- mAdc --- kVdc --- mAdc --- mAdc --- kVdc --- mAdc ---Minutes --- mW --- °C --- Watts --- VSWR --- lb/hr The values listed above represent specified limits for the product and are subject to change. The data should be used for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design. For information on this and other CPI products, visit our website at: www.cpii.com, or contact: CPI MPP Division, 607 Hansen Way, Palo Alto, CA 94303 telephone: 1(800) 414-8823. fax : (650) 856-0705 | email : [email protected] CPI 05/10 CPI k W C-band helix twt series CPI 2.25 | 4CW50,000J 2.25 kW, C-Band Helix TWT Series