200 W, CW Helix TWT Series, 13.75 GHz to 14.50 GHz, Periodic-Permanent, Magnet Focused, Coaxial Input and Waveguide Output, and Conduction Cooled. Custom configurations are also available. These variations in the performance and configuration include: mechanical configuration, electrical and RF connections, & dual stage depressed collector. Model Number Frequency (GHz) VTU-6395M2 13.75 – 14.50 200 Watts 13.75 GHz – 14.50 GHz PPM Focusing Coaxial Input Waveguide Output Any Mounting Position Weight: 6 lbs. Max Conduction Cooled 200 W Operating Parameters Features • • • • • • • • Power Output (Min.) Heater Voltage Parameters: Units: Maximum: Minimum: Heater Surge Current Helix Voltage Collector Voltage 1 Collector Voltage 2 Cathode Current Ef If Ew Eb1 Eb2 Ik V 6.6 6.0 A 5.0 --- kVdc 8.9 8.2 kVdc 0.52 Ew 0.48 Ew kVdc 0.34 Ew 0.30 Ew mAdc 240 --- Parameters: Helix Current Iw Drive Power Pd Cathode Warm-up Time tk Units: Maximum: Minimum: mAdc 240 --- mW 50 --- minutes --3 Load VSWR 1.5:1 --- The values listed above represent specified limits for the product and are subject to change. The data should be used for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design. For additional information on CPI MPP products contact: CPI MPP, Helix TWT Operation - 811 Hansen Way, Palo Alto, CA 94303-0750 Phone: 650-846-3900, Fax: 650-494-8779, Email: [email protected], www.cpii.com/mpp