AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS AC Output (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Resistive Load Current UL 508/ IEC 62314 LC-A [Arms, FLA] (2)
Minimum Load Current [Arms]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum Surge Current (50/60 Hz, 1 cycle) [Apk]
Maximum I²t for Fusing (50/60 HZ, 1/2 cycle) [A² sec]
UL 508 HP/IEC 62314 LC-B Rating @ 240V, 40°C [HP/KW]
Minimum Power Factor (with Maximum Load)
3A
5A
24-280
600
3
0.15
0.1
500
1.1
240/250
285/260
0.25 / 0.37
0.5
24-280
600
5
0.15
0.1
500
1.1
600/625
1780/1620
0.5 / 0.55
0.5
INPUT SPECIFICATIONS (1)
Description
ED24Dx
ED24Cx
ED24Fx
ED24Ex
ED24Bx
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Maximum Reverse Voltage
Minimum Input Current [mA]
Maximum Input Current [mA]
Nominal Input Impedance [ohms]
Maximum Turn-On Time [msec] (4)
Maximum Turn-Off Time [msec]
3-15 VDC
3 VDC
1.9 VDC
6 VDC
3.8
33.8
500
8.33
8.33
18-32 VDC
18 VDC
10.5 VDC
6 VDC
3.8
6.9
4.8K
8.33
8.33
48-72 VDC
48 VDC
24 VDC
6 VDC
3.8
5.8
12.5K
8.33
8.33
18-36 VAC
18 VAC
10 VAC
N/A
3.8
8.5
4.5K
20
30
90-140 VAC
90 VAC
48 VAC
N/A
3.2
4.9
28K
20
30
GENERAL SPECIFICATIONS (1)
Description
Dielectric Strength, Input/Output (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Maximum Humidity
Housing Material
Terminals Material
Parameters
3750 Vrms
109 Ohms
10 pF
-30ºC to 80ºC
-40ºC to 125ºC
1.06 oz. (30 g)
85% non-condensing
Polyamide Class V0 (UL94)
Copper w/Sulfamet Nickel finish
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Based on 17mm (5A model) and 13mm (3A model) spacing minimum between parts.
3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
4) Turn-On time for Random turn-on versions is 0.1ms for DC control and 5ms for AC control.
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
IEC 61000-4-2 : Electrostatic Discharge
IEC 61000-4-4 : Electrically Fast Transients
IEC 61000-4-5 : Electrical Surges
Level 3 – Criteria A
Level 3 – Criteria B
Level 3 – Criteria A
E374474
Rev 051211
ACCESSORIES