LED - Lamp ELD-410-533 20.11.2007 rev. 01 Radiation Type Technology Case Blue Standard InGaN/Al2O3 5 mm plastic lens Description 8,6 Ø5,9 ±0,2 Ø5,0 ±0,3 0,5 1 ±0,3 ±0,2 Note: Special packages with standoff available on request 2,54 Anode High-power, high-speed blue LED in standard 5 mm package, narrow beam angle, housing without standoff leads Applications 1,0 min Illumination, safety equipment, automation 25,4 min Absolute Maximum Ratings at Tamb = 25°C, unless otherwise specified Parameter Test сonditions Symbol Value Unit IF 30 mA IFM 60 mA Operating temperature range Tamb -20 to +80 °C Storage temperature range Tstg -30 to +100 °C Tj 100 °C Tsd 260 °C Typ Max Unit 3.3 3.6 V DC forward current Peak forward current tp≤10 µs, f≤500 Hz Junction temperature t ≤ 5 s, 3 mm from case Soldering temperature Optical and Electrical Characteristics Tamb = 25°C, unless otherwise specified Test conditions Symbol Forward voltage IF = 20 mA VF Reverse voltage IR = 10 µA VR 5V Radiant power IF = 20 mA Φe 6 8 mW Radiant intensity IF = 20 mA Ιe 20 35 mW/sr Peak wavelength IF = 20 mA λp 400 410 Spectral bandwidth at 50% IF = 20 mA ∆λ0.5 18 nm Viewing angle IF = 20 mA ϕ 25 deg. Switching time IF = 20 mA tr, tf 10/10 ns Parameter Min V 420 nm Note: All measurements carried out on EPIGAP equipment We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 1 of 3 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 LED - Lamp ELD-410-533 20.11.2007 rev. 01 Spectral power distribution (typical) at IF = 20 mA rel. Intensity (arb. units) 1,0 0,8 0,6 0,4 0,2 0,0 300 350 400 450 500 Wavelength (nm) Ambient Temperature vs. maximal forward current Max. forward current (mA) 30 20 10 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 Ambient Temperature (°C) We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 2 of 3 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 LED - Lamp ELD-410-533 20.11.2007 rev. 01 Remarks concerning optical radiation safety* Up to maximum forward current, at continuous operation, this LED may be classified as LED product Class 1 , according to standard IEC 60825-1:A2. Class 1 products are safe to eyes and skin under reasonably predictable conditions. This implicates a direct observation of the light beam by means of optical instruments. *Note: Safety classification of an optical component mainly depends on the intended application and the way the component is being used. Furthermore, all statements made to classification are based on calculations and are only valid for this LED "as it is", and at continuous operation. Using pulsed current or altering the light beam with additional optics may lead to different safety classifications. Therefore these remarks should be taken as recommendation and guideline only. LED Class 1 accord. DIN EN/IEC 60825-1:2001-11 We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications.All operating parameters must be validated for each customer application by the customer. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 3 of 3 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545