MOVING COIL TYPE ALARMING INDICATOR DATA SHEET PAK The moving coil type alarming indicator is designed to receive various input signals such as FC series signals. DC voltage or current, and signals from themocouples or resistance bulbs. FEATURES 1. Direct connection of input signals. 2. High input impedance (1MΩ for 1 to 5V DC input). No circuit adjusting resistor is required for thermocouple input. 3. Compact and lightweight. Input resistance and allowable input signal source resistance: SPECIFICATIONS Input signal: FC series signal A; 1 to 5V DC B; 4 to 20mA DC DC current D; 0 to 100µA ....... 200mA DC DC voltage E; 0 to 10mV ........ 5V DC Thermocouple F; 0 to 10mV DC or more (with reference junction compensator) (Upper limit overshoot burnout circuit is available on request) G; 10mV DC span or more (with reference junction compensator) (Upper limit overshoot burnout circuit is available on request) Resistance bulb H; JPt100Ω 50°C span or more, 3-wire type W; Pt100Ω 50°C span or more, 3-wire type Ring tube (resistance span 14Ω) Slide resistant (resistance span 100Ω) J; 3-wire type K; 2-wire type (with adjusting resistor) Opening angle transmitter (resistance span 100Ω) L; 3-wire type (zero point and span adjustable) Input resistance Allowable input signal source resistance 1 to 5V 1MΩ 2kΩ or less Others 40kΩ to 1MΩ 100Ω or less 4 to 20mA 5Ω Others 1 to 100Ω Input signal Voltage ––– Current Thermocouple Resistance 40 to 600kΩ ––– ––– 100Ω or less 50Ω or less when burnout circuit 6Ω or less per wire ± 1.0% of full scale 100mm Within 3 sec (time required for stabilizing the indicator pointer within ± 1.5% after applying input corresponding to 2/3 (approx.) of full scale) Power supply: 100V ± 10% AC, 50/60Hz *200V ± 10% AC, 50/60Hz, or +15% *24V –10% AC, 50/60Hz Power consumption: Approx. 4.5VA max. Ambient temperature: –10 to +50°C Ambient humidity: 30 to 90%RH Enclosure: Steel case External dimensions (H × W × D): 48 × 144 × 275mm Mass{weight}: Approx. 2kg Finish color: Munsell 7.5BG 3.2/0.8 or equivalent Allowance: Scale length: Response time: EDS10-46c Date Feb. 28, 1991 PAK Alarm device: Upper limit (H or A), lower limit (L or B) Upper and lower limits (K or C with one common contact) H, L, K; Excitation alarm A, B, C; Non-excitation alarm Setting accuracy; ± 1.0% Contact; ON alarm (OFF alarm is available on request) Contact capacity; 100V AC 0.3A/24V DC 0.2A (resistance load) Alarm indicator lamp (available on request); Alarm signal displayed with LED mounted on indicator panel CODE SYMBOLS 1 2 3 4 5 6 7 8 PAK 9 10 Description 2 Input signal 1 to 5V DC 4 to 20mA DC 0 to 100µA.....200mA DC 0 to 10mV.....5V DC 0 to 10mV DC or more (with reference junction compensator) 10mV DC span or more (with reference junction compensator) Resistance bulb JPt100Ω 50°C span or more, 3-wire type Resistance bulb Pt100Ω 50°C span or more, 3-wire type Ring tube, slide resistant, 3-wire type Ring tube, slide resistant, 2-wire type (with circuit adjusting resistor) Opening angle indicator (resistance 100Ω, zero point and span adjustable) Other inputs Alarm device Upper limit Lower limit Excitation alarm Upper and (ON alarm) lower limits Upper limit Lower limit Non-excitation alarm Upper and (ON alarm) lower limits A B D E F G H W J K L * Z H L K *A *B *C Power supply 24V AC 50/60Hz 100V AC 50/60Hz 200V AC 50/60Hz * 1 3 * 5 Application For general use For connection zener barrier: Specify “3” only when zener barrier (PWZB3 or PMZB4) is to be connected and thermocouple or resistance bulb is used as input source. 0 3 1 * 2 0 * 1 Mounting method Horizontal mounting Vertical mounting Alarm indicator lamp None Provided Notes: Symbols of resistance bulbs are as follows. JPt100 Previous JIS standard Pt100 New JIS standard Scope of delivery : Indicator and mounting bracket Mounting method: Panel flush mounting Standard; Horizontal mounting on vertical panel Non-standard; Tilted mounting, vertical mounting Specify ∠α for tilted mounting OUTLINE DIAGRAM (Unit : mm) CONNECTION DIAGRAMS PAK ORDERING INFORMATION 1. 2. 3. 4. 5. Product name Code symbols Input Scale Alarm device and alarm indicator lamp (whether required or not) 6. Power supply 7. Application 8. Other necessary information Caution on Safety • Asterisked (*) items; Non-standard *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan