MOVING COIL TYPE INDICATOR DATA SHEET PAJ The moving coil type indicator receives various types of input signals, DC voltage, DC current, and signals from thermocouple and resistance bulbs. FEATURES 1. Input signal can be directly connected. 2. High input impedance (1MΩ at 1 to 5V DC input). No adjusting resistor is required for thermocouple input. 3. Compact and lightweight design. SPECIFICATIONS Input resistance and allowable input signal source resistance: Input resistance Allowable input signal source resistance 1 to 5V 1MΩ 2kΩ or less Others 40kΩ to 1MΩ 100Ω or less 4 to 20mA 5Ω – Others 1 to 100Ω – Input signal Measuring input: Signal A; 1 to 5V DC B; 4 to 20mA DC DC current D; 0 to 100µA ....... 200mA DC DC voltage E; 0 to 10mV ........ 5V DC Thermocouple F; 0 to 10mV DC or more (with reference junction compensator) (Upper limit overshoot burnout circuit is available on request) Thermocouple G; 10mV DC span or more (with reference junction compensator) (Upper limit overshoot burnout circuit is available on request) Resistance bulb H; JPt100Ω 50°C span or more 3-wire type W; Pt100Ω 50°C span or more 3-wire type Slide resistant (resistance span; 100Ω) J; 3-wire type K; 2-wire type (with adjusting resistor) Opening angle transmitter (resistance span: 100Ω) L; 3-wire type (zero point and span adjustable) Voltage Current Thermocouple Resistance 100Ω or less 40 to 600kΩ – (50Ω or less when burnout is provided) 6Ω or less per wire ± 1.0% of full scale 100mm Within 3 sec (time required for stabilizing the indicator pointer within ± 1.5% after applying input corresponding to 2/3 (approx.) of full scale) Power supply: 100V ± 10% AC, 50/60Hz *200V ± 10% AC, 50/60Hz, or +15% *24V –10% AC, 50/60Hz Power consumption: Approx. 1.8VA max. Ambient temperature: –10 to +50°C Ambient humidity: 30 to 90%RH Enclosure: Steel case External dimensions (H × W × D): 48 × 144 × 210mm Mass{weight}: Approx. 1.5kg Finish color: Munsell 7.5BG 3.2/0.8 or equivalent Scope of delivery:Indicator and mounting bracket Allowance: Scale length: Response time: EDS10-45e Date July. 15, 1993 PAJ Mounting method: Panel flush mounting Standard; Horizontal mounting on vertical panel Non-standard; Tilted mounting, vertical mounting Specify ∠α when mounting on tilted panel OUTLINE DIAGRAM (Unit : mm) CODE SYMBOLS 1 2 3 4 5 6 7 8 P AJ 0 9 Description 2 Input signal 1 to 5V DC 4 to 20mA DC 0 to 100µA.....200mA DC 0 to 10mV.....5V DC 0 to 10mV DC or more (with reference junction compensator) 10mV DC span or more (with reference junction compensator) Resistance bulb JPt100Ω 50°C span or more, 3-wire type Resistance bulb Pt100Ω 50°C span or more, 3-wire type Slide resistant, 3-wire type Slide resistant, 2-wire type (with circuit adjusting resistor) For opening angle indicator (resistance; 100Ω, zero point and span adjustable) Other inputs A B D E F G H W J K L *Z CONNECTION DIAGRAMS Power supply 24V AC 50/60Hz 100V AC 50/60Hz 200V AC 50/60Hz *1 3 *5 Application For general use For zener barrier connection Specify "3" only when connecting to zener barrier (PWZB3 or PWZB4) with thermocouple or resistance bulb input used. 0 3 1 2 Mounting method Horizontal mounting Vertical mounting Notes: Symbols of resistance bulbs are as follows. JPt100 Previous JIS standard Pt100 New JIS standard ORDERING INFORMATION 1. 2. 3. 4. Product name Code symbols Input Scale 5. Power supply 6. Application 7. Other necessary information Caution on Safety • Asterisked (*) items; Non-standard *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan