FC SERIES SELF-BALANCING RECORDER DATA SHEET PFA The FC SERIES self-balancing recorder is capable of continuously recording up to three types of inputs like process signal, DC voltage, current, thermocouple signal, resistance bulb signal, etc. Alarm units for the individual pens, external chart speed selector convenient for plant instrumentation, marking pen and many other optional accessories are prepared inside the self-balancing recorder. It is also usable as a trend recorder for 18 input points when combined with input selector (Type: PFC). FEATURES 1. Compact design measuring 96 mm wide by 144 mm high (front panel) by 400 mm deep (casing). 2. The recorder uses a folding type chart, of which one stack allows continuous recording for a month at a standard chart speed of 20 mm/h. 3. Data are indicated in bargraphs with color ribbon. 4. The servo-mechanism consists of a contactless induction potentiometer and a powerful coreless-motor, thereby assuring high reliability. 5. Chart speed is set accurately and can be switched easily by a combination of a clock circuit comprising a crystal oscillator and a pulse-motor. 6. The recorder can operate within a wide DC voltage range of 20 to 30V, or commonly at 50 and 60 Hz with an AC power supply. 7. The recording pen is a cartridge type felt-tip pen requiring a minimum of maintenance. SPECIFICATIONS Input signal: Process signal; 1 to 5V DC, 4 to 20mA DC DC voltage; 4mV span or more (30V max.) DC current; 100µA span or more (200mA max.) Thermocouple; 4mV span or more (Cold junction compensation, linearizer and burnout circuit built in.) Resistance bulb; Pt100 50°C span or more, 3wire system (linearizer built in) JPt100 in accordance with JIS C 1604-1981, 50°C span or more, 3wire system (linearizer built in) Slide rheostat; 10–100–10Ω, 3-wire system Input resistance and allowable signal source resistance: See page 3 Allowance: ± 0.5% of input span or ± 40 µV, whichever is larger Dead band: 0.2% of input span or 16 µV, whichever is larger Response time: Approx. 5 sec (variable within a range of approx. 2 to 20 sec) Number of recording points: 1, 2 or 3 pens Recording pens: Cartridge type felt-tip pen Pen No. 1 ... red, pen No. 2 ... green, pen No. 3 ... blue Scale length: 100mm (recording width) Chart length: 15m (continuous recording for 31 days at 20mm/h) Chart feed system: Pulse-motor type (driving pulse generator circuit built in) Chart storage system: Folding system Chart speed: 20mm/h basic (10, 30, 40, 60 and 120mm/h also selectable) Chart speed accuracy: ± 0.1% as measured on time axis on the chart EDS10-15f Date Aug. 31, 1994 PFA Power supply: 24V (20 to 30V) DC or 100V ± 10%, 50/60Hz AC Power indicator lamp: Rectangular green LED Power consumption: Approx. 5.5W (24V DC) or approx. 8VA (100V AC) for 1-pen type Approx. 8W (24V DC) or approx. 12VA (100V AC) for 2-pen type Approx. 10W (24V DC) or approx. 15VA ( 100V AC) for 3-pen type Ambient temperature: Note: Temperature [°C] 0 to 45°C x humidity [% RH] Ambient humidity: 3000 30 to 90% RH Housing: Steel case External dimensions (HxWxD): 144x96x400mm (casing) + terminal board Mass{weight}(approx): 1-pen type; 5 kg 2-pen type; 5.5 kg 3-pen type; 6 kg Finish color: Munsell 7Y 7.3/1.4 (Case, front frame) Mounting: Panel flush-mounting Marking unit: } External selecting signal; Terminals F—F High speed selected by short circuited (Contact capacity; 5V, 10mA) Time marker; Recording of impulselike spike on lower end of chart at definite time intervals (2 min basic) Externally controlled marker; Operating only while terminals M—M are short circuited in external sequence. Contact capacity: 24V, 50mA Marking pen; Cartridge type felt-tip pen (blue) 2min 2min 0% Low speed High speed Time marker α α=90° to 45° Scope of delivery: Recorder, mounting bracket and standard accessories (see page 3) Specifications for optional units Alarm unit: Type; Comparator circuit type Upper limit + lower limit, two upper limits or two lower limits (for each pen) Setting accuracy; ± 1% of input span Hysteresis width; Approx. 0.4% of input span Output contacts; N.O (1a) contacts for upper limit and lower limit (excited at alarm condition) Contact capacity; Maximum voltage 125V AC/30V DC Current (breaking) Resistance load: 0.3A or less Relay load: 0.2A or less Note: Alarm output stabilized several seconds after turning ON power switch. If necessary, the user is to provide an external sequence such as a timer for cutting off output at start time. Chart speed selector: Selector; Internal switch or external sequence for selecting a preset low or high speed Low speed; 10, 20, 30, 40, 60, 120 mm/h High speed; 120, 300, 600, 1200, 3000, 6000,12000mm/h 2 ON OFF ON OFF Driven by external sequence Indication pause: Indicator (recorder pen) is paused by short circuited terminals PS — PS via external sequence. (Contact capacity; 20V, 50mA) Note: Alarm device continues monitoring even while the indication is paused. Input resistance and allowable signal source resistance List of chart Nos. (standard charts) Es (Is) indicates input span (unit: mV or mA) Voltage input Input resistance Input 4 Es 200mV 0.2<Es 1V Type Current input Allowable signal source resistance 100kΩ or more 100Ω Approx. 100kΩ 100Ω 1<Es<4V Approx. 470kΩ 470Ω 4 Es 30V 1 MΩ 1 kΩ Process signal 1 to 5V 1 MΩ 1 kΩ Input 0.1 Is 10mA Input resistance 50/Is Ω — — 10<Is 200mA — Process signal 4 to 20mA 5Ω — 250 Ω 4 Es 40mV with burnout circuit Es/4 x 104Ω Es/0.4Ω 10 to 50mA 100 Ω 40<Es 80mV with burnout circuit Es/8 x 104Ω Es/0.8Ω — — Note: Wiring resistance: 6 Ω or less per wire (each wire resistance should be equal value) Standard accessories PFA1 PFA2 PFA3 3 3 3 Red 2 2 2 Green — 2 2 Blue — — 2 1 1 1 Chart Recording pen Oil Equal graduations (without graduation numerals) Equal graduations (with graduation numerals) Graduation numeral Number of Chart No. sections — 40 FL-4000-S — 50 FL-5000-S — 60 FL-6000-S — 70 FL-7000-S — 75 FL-7500-S — 80 FL-8000-S 0 to 40, 0 to 200 200 to 400 40 FL-4001-S 0 to 25, 50, 100 50 FL-5001-S 0 to 30, 60, 120 60 FL-6001-S 0 to 14, 0 to 70 700 to 1400 70 FL-7001-S 0 to 150, 50 to 200 100 to 250 75 FL-7501-S 0 to 80, 0 to 1600 800 to 1600 80 FL-8001-S Remarks: (1) Standard chart speed 20mm/h. Different chart speeds available for non-standard specifications. (2) The symbol added to the end of chart Nos. Denotes chart speed. S: 20mm/h (basic) L: 10mm/h, X: 60mm/h, Y: 120mm/h Z: Graduation in length (same graduations are repeated at every 1m rg.). (3) The non-standard chart should be ordered as a set of 24. Marker pen 3 (only when marker equipped) Remarks: Chart to be supplied as standard accessory should in principle be selected from among the standard charts) 3 PFA CODE SYMBOLS 1 2 3 4 5 6 7 8 PFA 9 10 11 12 13 Description 1 - Number of recording points 1-pen 2-pen 3-pen 1 2 3 Input signal (*4) Pen No, 1, pen No.2, pen No.3 1 to 5V DC 4 to 20mA DC 4mV DC span or more, max. voltage 30V 100µA DC span or more, max. current 200mA Thermocouple input, 4mV span or more (*1) (*2) Same as above, for connecting zener barrier Resistance bulb JPt 100, 3-wire type, 50 °C span or more Same as above, for connecting zener barrier Resistance bulb Pt 100, 3-wire type, 50 °C span or more Same as above, for connecting zener barrier Slide rheostat, 3-wire type None A B E D F T H M W N J Y Entries of input codes ( 5th digit (*7) to be filled with input code) (*6) 6th digit 7th digit Y Y 1-pen 2-pen Y 3-pen Power supply 24V DC 100V AC 1 2 * * * * * * Y A B C D E F G Common optional units Without optional units With time marker With externally controlled marker Same as above, for one-shot operation Low/high chart speed selection A+D B+D (*5) C+D Y K *H * L D E 1st pen, optional units Without optional units Upper limit + lower limit alarm Two upper limits alarm (*3) Two lower limits alarm Indication pause Unusable for thermocouple input K+D Y K *H * L D E Y K *H * L D E 2nd pen, optional units Without optional units Upper limit + lower limit alarm Two upper limits alarm (*3) Two lower limits alarm Indication pause Unusable for thermocouple input K+D 3rd pen, optional units Without optional units Upper limit + lower limit alarm Two upper limits alarm (*3) Two lower limits alarm Indication pause Unusable for thermocouple input K+D Notes: * (1) Cold junction compensation and burnout circuit (upscale) are provided with recorder for thermocouple input. (2) Minimum temperature range (span) of thermocouple: K: 150°C J: 100°C T: 150°C E: 100°C R: 500°C (3) Alarm units are to be added consecutively from pen No. 1 to pen No. 3. (4) Linearizer is to be provided for direct inputs from thermocouple and resistance bulb. (5) When all three pens are recorded thermocouple inputs and are equipped with alarm devices, E, F or G cannot be specified in 10th digit (due to number of terminals). (6) Example of instrument code specifications: PFA2ABY1-1YKYY (7) JPt 100…JIS C 1604-1981 Pt100…IEC Pub 751-1983 • Asterisked (*) items; Nonstandard. 4 PRINCIPLE OF OPERATION Amplifier cards (1 to 3) Range card Input signal I+ Ei Linearizer Bridge circuit I- Filter Servo amplifire Balancing motor (DC motor) IP amplifire Induction potentiometer Ea Rcu Pulley Eb Rmn Ea Wire rope Alarm settre circuit Recording pen Alarm output card Ei Relay Alarm output Ea Power supply circuit Power supply Making pen Clock circuit +VP Maker circuit Switching regulator Pulse-motor PC Solenoid OUTLINE DIAGRAM (Unit:mm) Terminal cover Lock screw for transportation (remove after receipt the recorder) Panel thickness 8mm or less 137 144 Mounting bracket 96 16 165 Terminal rating plate Min. 200 Support 400 15 90 38 Panel cutout For mounting "n" units recorders For combination of recorder and input selector PFC 138 +1 0 Min. 200 For mounting single recorder 92 ± 0.8 (96.2n–4) ± 1 140 ± 0.8 5 PFA EXTERNAL CONNECTION DIAGRAM Indication pause signal 1PS 1 11 I1 0 I1 + 21 I1 – 22 I2 + 23 I2 – 24 I3 + 25 I3 – 26 1H 27 1H 28 2H 29 2H 30 3H 31 3H 32 1st Pen 1PS 2 12 2PS I2 0 3 13 2PS 3PS 4 14 I3 0 3PS 5 2nd Pen 3rd Pen 15 Aux signal 6 16 1L 17 1L 1st Pen 2L 7 2nd Pen 2L 8 18 VP 3L 9 19 PC 20 G 3L 10 3rd Pen Power supply Lower limit alarm output 1st Pen (Red) 2nd Pen (Green) Input signal 3rd Pen (Blue) 1st Pen (Red) 2nd Pen (Green) Upper limit alarm outputs 3rd Pen (Blue) (A) Connections for various input signals (a) Thermocouple input, voltage input In+ In- (b) Resistance input Slide rheostat Resistance bulb In+ 100% In0 In+ Ino In– In– 0% (B) Connections for auxiliary signals (b) Marker drive (a) Fast chart feed or F F M M 3PS M 3PS M ( According to specifications, 3PS teminals ) will be used as M terminals. RELATED DEVICES Input selector PFC ORDERING INFORMATION 1. Name of instrument 2. Type 3. Inputs 4. Scale graduation 5. Optional devices required 6. Power requirements 7. Other remarks Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan