FUJI EDS10-15F

FC SERIES
SELF-BALANCING RECORDER
DATA SHEET
PFA
The FC SERIES self-balancing recorder is capable of
continuously recording up to three types of inputs like
process signal, DC voltage, current, thermocouple signal,
resistance bulb signal, etc. Alarm units for the individual
pens, external chart speed selector convenient for plant
instrumentation, marking pen and many other optional
accessories are prepared inside the self-balancing recorder.
It is also usable as a trend recorder for 18 input points when
combined with input selector (Type: PFC).
FEATURES
1. Compact design measuring 96 mm wide by 144 mm high
(front panel) by 400 mm deep (casing).
2. The recorder uses a folding type chart, of which one stack
allows continuous recording for a month at a standard
chart speed of 20 mm/h.
3. Data are indicated in bargraphs with color ribbon.
4. The servo-mechanism consists of a contactless induction
potentiometer and a powerful coreless-motor, thereby
assuring high reliability.
5. Chart speed is set accurately and can be switched easily
by a combination of a clock circuit comprising a crystal
oscillator and a pulse-motor.
6. The recorder can operate within a wide DC voltage range
of 20 to 30V, or commonly at 50 and 60 Hz with an AC
power supply.
7. The recording pen is a cartridge type felt-tip pen requiring
a minimum of maintenance.
SPECIFICATIONS
Input signal:
Process signal;
1 to 5V DC, 4 to 20mA DC
DC voltage; 4mV span or more
(30V max.)
DC current; 100µA span or more
(200mA max.)
Thermocouple; 4mV span or more
(Cold junction compensation, linearizer
and burnout circuit built
in.)
Resistance bulb; Pt100
50°C span or more, 3wire system
(linearizer built in)
JPt100 in accordance
with JIS C 1604-1981,
50°C span or more, 3wire system (linearizer
built in)
Slide rheostat; 10–100–10Ω,
3-wire system
Input resistance and allowable signal source resistance:
See page 3
Allowance:
± 0.5% of input span or ± 40 µV, whichever is larger
Dead band:
0.2% of input span or 16 µV, whichever
is larger
Response time: Approx. 5 sec (variable within a range of
approx. 2 to 20 sec)
Number of recording points:
1, 2 or 3 pens
Recording pens: Cartridge type felt-tip pen
Pen No. 1 ... red, pen No. 2 ... green,
pen No. 3 ... blue
Scale length:
100mm (recording width)
Chart length:
15m (continuous recording for 31 days
at 20mm/h)
Chart feed system:
Pulse-motor type (driving pulse generator circuit built in)
Chart storage system:
Folding system
Chart speed:
20mm/h basic
(10, 30, 40, 60 and 120mm/h also
selectable)
Chart speed accuracy:
± 0.1% as measured on time axis on the
chart
EDS10-15f
Date
Aug. 31, 1994
PFA
Power supply:
24V (20 to 30V) DC or
100V ± 10%, 50/60Hz AC
Power indicator lamp:
Rectangular green LED
Power consumption:
Approx. 5.5W (24V DC) or approx.
8VA (100V AC) for 1-pen type
Approx. 8W (24V DC) or approx.
12VA (100V AC) for 2-pen type
Approx. 10W (24V DC) or approx.
15VA ( 100V AC) for 3-pen type
Ambient temperature:
Note: Temperature [°C]
0 to 45°C
x humidity [% RH]
Ambient humidity:
3000
30 to 90% RH
Housing:
Steel case
External dimensions (HxWxD):
144x96x400mm (casing)
+ terminal board
Mass{weight}(approx):
1-pen type;
5 kg
2-pen type;
5.5 kg
3-pen type;
6 kg
Finish color:
Munsell 7Y 7.3/1.4 (Case, front frame)
Mounting:
Panel flush-mounting
Marking unit:
}
External selecting signal;
Terminals F—F
High speed selected by
short circuited
(Contact capacity; 5V,
10mA)
Time marker; Recording of impulselike
spike on lower end of
chart at definite time
intervals
(2 min basic)
Externally controlled marker;
Operating only while terminals M—M are short
circuited in external sequence.
Contact capacity:
24V, 50mA
Marking pen; Cartridge type felt-tip pen
(blue)
2min
2min
0%
Low
speed
High
speed
Time marker
α
α=90° to 45°
Scope of delivery: Recorder, mounting bracket and standard
accessories (see page 3)
Specifications for optional units
Alarm unit:
Type; Comparator circuit type
Upper limit + lower limit, two
upper limits or two lower limits
(for each pen)
Setting accuracy;
± 1% of input span
Hysteresis width;
Approx. 0.4% of input span
Output contacts;
N.O (1a) contacts for upper limit
and lower limit (excited at alarm
condition)
Contact capacity;
Maximum voltage 125V AC/30V
DC
Current (breaking)
Resistance load: 0.3A or less
Relay load: 0.2A or less
Note: Alarm output stabilized several
seconds after turning ON power switch.
If necessary, the user is to provide an
external sequence such as a timer for
cutting off output at start time.
Chart speed selector:
Selector; Internal switch or external
sequence for selecting a preset low or high speed
Low speed; 10, 20, 30, 40, 60,
120 mm/h
High speed; 120, 300, 600, 1200,
3000, 6000,12000mm/h
2
ON
OFF
ON
OFF
Driven by external sequence
Indication pause: Indicator (recorder pen) is paused by short
circuited terminals PS — PS via external
sequence.
(Contact capacity; 20V, 50mA)
Note: Alarm device continues monitoring even
while the indication is paused.
Input resistance and allowable signal source
resistance
List of chart Nos.
(standard charts)
Es (Is) indicates input span (unit: mV or mA)
Voltage input
Input
resistance
Input
4 Es 200mV
0.2<Es 1V
Type
Current input
Allowable
signal
source
resistance
100kΩ
or more
100Ω
Approx.
100kΩ
100Ω
1<Es<4V
Approx.
470kΩ
470Ω
4 Es 30V
1 MΩ
1 kΩ
Process
signal
1 to 5V
1 MΩ
1 kΩ
Input
0.1 Is 10mA
Input
resistance
50/Is Ω
—
—
10<Is 200mA
—
Process
signal
4 to 20mA
5Ω
—
250 Ω
4 Es 40mV
with burnout
circuit
Es/4
x 104Ω
Es/0.4Ω
10 to 50mA
100 Ω
40<Es 80mV
with burnout
circuit
Es/8
x 104Ω
Es/0.8Ω
—
—
Note: Wiring resistance: 6 Ω or less per wire (each wire resistance should be equal
value)
Standard accessories
PFA1
PFA2
PFA3
3
3
3
Red
2
2
2
Green
—
2
2
Blue
—
—
2
1
1
1
Chart
Recording
pen
Oil
Equal
graduations
(without
graduation
numerals)
Equal
graduations
(with
graduation
numerals)
Graduation
numeral
Number
of
Chart No.
sections
—
40
FL-4000-S
—
50
FL-5000-S
—
60
FL-6000-S
—
70
FL-7000-S
—
75
FL-7500-S
—
80
FL-8000-S
0 to 40, 0 to 200
200 to 400
40
FL-4001-S
0 to 25, 50, 100
50
FL-5001-S
0 to 30, 60, 120
60
FL-6001-S
0 to 14, 0 to 70
700 to 1400
70
FL-7001-S
0 to 150, 50 to 200
100 to 250
75
FL-7501-S
0 to 80, 0 to 1600
800 to 1600
80
FL-8001-S
Remarks: (1) Standard chart speed 20mm/h. Different chart
speeds available for non-standard specifications.
(2) The symbol added to the end of chart Nos.
Denotes chart speed.
S: 20mm/h (basic)
L: 10mm/h, X: 60mm/h, Y: 120mm/h
Z: Graduation in length (same graduations are
repeated at every 1m rg.).
(3) The non-standard chart should be ordered as
a set of 24.
Marker pen 3 (only when marker equipped)
Remarks: Chart to be supplied as standard accessory should
in principle be selected from among the standard
charts)
3
PFA
CODE SYMBOLS
1 2 3 4 5 6 7 8
PFA
9 10 11 12 13
Description
1 -
Number of recording points
1-pen
2-pen
3-pen
1
2
3
Input signal (*4)
Pen No, 1, pen No.2, pen No.3
1 to 5V DC
4 to 20mA DC
4mV DC span or more, max. voltage 30V
100µA DC span or more, max. current 200mA
Thermocouple input, 4mV span or more
(*1) (*2)
Same as above, for connecting zener barrier
Resistance bulb JPt 100, 3-wire type, 50 °C span or more
Same as above, for connecting zener barrier
Resistance bulb Pt 100, 3-wire type, 50 °C span or more
Same as above, for connecting zener barrier
Slide rheostat, 3-wire type
None
A
B
E
D
F
T
H
M
W
N
J
Y
Entries of input codes (
5th digit
(*7)
to be filled with input code) (*6)
6th digit
7th digit
Y
Y
1-pen
2-pen
Y
3-pen
Power supply
24V DC
100V AC
1
2
*
*
*
*
*
*
Y
A
B
C
D
E
F
G
Common optional units
Without optional units
With time marker
With externally controlled marker
Same as above, for one-shot operation
Low/high chart speed selection
A+D
B+D (*5)
C+D
Y
K
*H
* L
D
E
1st pen, optional units
Without optional units
Upper limit + lower limit alarm
Two upper limits alarm
(*3)
Two lower limits alarm
Indication pause
Unusable for thermocouple input
K+D
Y
K
*H
* L
D
E
Y
K
*H
* L
D
E
2nd pen, optional units
Without optional units
Upper limit + lower limit alarm
Two upper limits alarm
(*3)
Two lower limits alarm
Indication pause
Unusable for thermocouple input
K+D
3rd pen, optional units
Without optional units
Upper limit + lower limit alarm
Two upper limits alarm
(*3)
Two lower limits alarm
Indication pause
Unusable for thermocouple input
K+D
Notes: * (1) Cold junction compensation and burnout circuit
(upscale) are provided with recorder for thermocouple input.
(2) Minimum temperature range (span) of thermocouple:
K: 150°C
J: 100°C
T: 150°C
E: 100°C
R: 500°C
(3) Alarm units are to be added consecutively from pen
No. 1 to pen No. 3.
(4) Linearizer is to be provided for direct inputs from thermocouple and resistance bulb.
(5) When all three pens are recorded thermocouple inputs and
are equipped with alarm devices, E, F or G cannot be
specified in 10th digit (due to number of terminals).
(6) Example of instrument code specifications:
PFA2ABY1-1YKYY
(7) JPt 100…JIS C 1604-1981
Pt100…IEC Pub 751-1983
• Asterisked (*) items; Nonstandard.
4
PRINCIPLE OF OPERATION
Amplifier cards (1 to 3)
Range card
Input
signal
I+
Ei
Linearizer
Bridge
circuit
I-
Filter
Servo
amplifire
Balancing motor
(DC motor)
IP
amplifire
Induction
potentiometer
Ea
Rcu
Pulley
Eb
Rmn
Ea
Wire rope
Alarm
settre
circuit
Recording
pen
Alarm output card
Ei
Relay
Alarm
output
Ea
Power
supply
circuit
Power
supply
Making pen
Clock circuit
+VP
Maker circuit
Switching regulator
Pulse-motor
PC
Solenoid
OUTLINE DIAGRAM
(Unit:mm)
Terminal cover
Lock screw for
transportation
(remove after
receipt the recorder)
Panel thickness
8mm or less
137
144
Mounting
bracket
96
16
165
Terminal
rating plate
Min. 200
Support
400
15
90
38
Panel cutout
For mounting "n"
units recorders
For combination of recorder
and input selector PFC
138
+1
0
Min. 200
For mounting
single recorder
92 ± 0.8
(96.2n–4) ± 1
140 ± 0.8
5
PFA
EXTERNAL CONNECTION DIAGRAM
Indication
pause signal
1PS
1
11
I1 0
I1 +
21
I1 –
22
I2 +
23
I2 –
24
I3 +
25
I3 –
26
1H
27
1H
28
2H
29
2H
30
3H
31
3H
32
1st Pen
1PS
2
12
2PS
I2 0
3
13
2PS
3PS
4
14
I3 0
3PS
5
2nd Pen
3rd Pen
15
Aux signal
6
16
1L
17
1L
1st Pen
2L
7
2nd Pen
2L
8
18
VP
3L
9
19
PC
20
G
3L
10
3rd Pen
Power
supply
Lower limit
alarm output
1st Pen
(Red)
2nd Pen
(Green)
Input signal
3rd Pen
(Blue)
1st Pen
(Red)
2nd Pen
(Green)
Upper limit alarm outputs
3rd Pen
(Blue)
(A) Connections for various input signals
(a)
Thermocouple input, voltage input
In+
In-
(b) Resistance input
Slide rheostat
Resistance bulb
In+
100%
In0
In+
Ino
In–
In–
0%
(B) Connections for auxiliary signals
(b) Marker drive
(a) Fast chart feed
or
F
F
M
M
3PS
M
3PS
M
( According to specifications, 3PS teminals )
will be used as M terminals.
RELATED DEVICES
Input selector PFC
ORDERING INFORMATION
1. Name of instrument
2. Type
3. Inputs
4. Scale graduation
5. Optional devices required
6. Power requirements
7. Other remarks
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan
http://www.fesys.co.jp/eng
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http: //www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan