FC SERIES RATIO SETTER DATA SHEET PNG1 The FC series ratio setter is used to set ratio for ratio control, and its set point signal is transmitted to a controller. This instrument uses a solid state indicator and a pushbutton operation system to provide reliable monitoring and operating functions. It also accepts a thermocouple, a resistance bulb and a 4 to 20mA DC input optionally. FEATURES 1. High reliability This instrument is designed with few mechanical parts. It is mainly composed of electronic parts such as a solid state indicator which was formerly consisted of mechanical parts. 2. International standards This instrument is compact in size, conforming to international standards IEC. It operates on 24V DC power to deliver 1 to 5V DC signals as recommended by IEC standards. 100 and 200V AC power are also available for convenience of operation. 3. Front panel operation Process values and set points can be read accurately with digital indications on panel front. Various parameter settings and setting operations are also possible from the front panel of the instrument. FUNCTIONAL DIAGRAM PV Linearize Square-root extraction SV SO Local mode output (LS) Remote reques (R-REQ) Filter Compensated process value signal (KPV) Process value input (PV) Limiter R B1 B2 B3 SO = R X (SV+B3) X (PV–B1) + B2 H Set point output (SO) L Squared set point output (SO2) SO2 External set point input (CAS or PI) (1 to 5V DC, pulse width, or pulse number) Remote acknowledge signal (R-ACK) Limiter H R L Ratio output signal (SV) L SV KPV ALM High alarm output (H) Low alarm output (L) EDS11-106e Date Jul. 1, 1994 PNG1 SPECIFICATIONS 1. Ratio computing function (2) Digital output signal: 5 points Computing formula Fault output SO=R(SV+B3)(PV–B1)+B2 Computation output Ratio factor FLT High alarm output H Low alarm output L Local mode output Remote request LS Open-collector output (photocoupler insulation) Output rating, 30V x 0.1A DC max. R-REQ Ratio set point Bias 3 4. Indication, setting, operating functions Process value (1) Bargraph indication Bias 1 Bias 2 Ratio factor and ratio bias: Setting range; –327.6 to 327.67% Computation cycle: 0.1 sec. 2. Input signal (1) Process value input signal: One input selectable from the following Voltage input signal 1 to 5V DC Input resistance, 1MΩ or more Current input signal 4 to 20mA DC 24V ± 2V DC can be Allow. error supplied to transmitter ± 0.2%/FS* in case of AC power supply approx. 35mA I+ Thermocou- I 0 Type I – J: 0 to 600°C ple input K: 0 to 1200°C E: 0 to 800°C R: 0 to 1600°C Resistance bulb input JPt100/Pt100 –50 to 500°C Allow. error ± 0.2%/FS* Allow. error 10mV DC span or more ± 0.5%/FS* cold junction compensation comprised 50°C span or more Allow. error ± 0.5%/FS* Note: *FS: Full scale (2) Analog input signal: 1 point External set point CAS 1 to 5V DC Input resistance, 1MΩ or more Allow. error ± 0.2%/FS (3) Digital input signal: 1 point Remote acknowledge signal R-ACK Contact input (photo-coupler insulation) ON 0V, OFF 24V ( input current, approx. 11mA/24V DC) (4) Pulse width or pulse number input signal: 1 set (eithre one) Pulse width input signal Pulse number input signal Contact input (photo-coupler insulation) Pl+ Pl– ON 0V, OFF 24V ( input current, approx. 11mA/24V DC) ON 0V, OFF 24V ( approx. 11mA/24V DC), max. input frequency 500Hz 3. Output signal (1) Analog output signal: 4 points 2 Compensated process value signal KPV Ratio output signal SV Set point output SO Squared set point output SO2 1 to 5V DC Output resistance, 1Ω or less Allow. error ± 0.2%/FS PV indicator SV indicator SO indicator Indication method LED (red) LED (green) LED (red) No. of segments 101 + 2 Range 0 to 100%, linear Resolution 1 %/FS 2%/FS Scale length 100mm 50mm Indicating mode 0 to 100% bargraph indication, 0 to 100% reverse bargraph indication, dot indication, –50 to +50% deviation indication 51 + 2 (2) Operation mode indication Indicating method: LED (green) Green: L, R (3) Numerical value indication, setting Indication method: LED (red), name in 3 digits + numerical value in 5 digits (negative sign included) Contents of indication: Process value (industrial value), set point (industrial value), high/low alarm, etc. Indication contents are selectable by F/S , , keys on front panel. Setting method: By using F/S , , , , ST keys on front panel (4) Setting functions Fixed value setting method: By using of , pushbuttons on front panel. Setting speed, approx. 40 sec/FS Remote setting method: By use of external set point signal (voltage or pulse input) Tracking speed setting range; 0 to 900 sec/FS (5) Operation mode changeover By using of R/L pushbutton on front panel. R R L changeover L changeover Balanceless bumpless Voltage signal* Balance bumpless Pulse width signal Balanceless bumpless Note: * Balanceless bumpless by setting tracking speed 5. Power failure processing function Power failure detection: Setting output held at power failure detection. During power failure: Operating parameters backed up by capacitor up to 5 minutes. Initial value of set point is stored in non-volatile memory (lasts 10 years expected at ambient temperature of 50° C or less). Power failure recovery: Initial or continuous start mode can be set within 5 minutes of power failure. Recovery from power failure lasting longer than 5 minutes is done by initial. Note: ** Control mode at initialzation can be registered L: Local mode or R: Remote mode 6. Self-diagnosis functions Computing circuit abnormality: FLT lamp lights, FLT contact output "ON". Manual operation output possible Input/output signal abnormality: FLT lamp lights, FLT contact output "ON", computation stops, operating output held Fault contents indication: Cause of fault is indicated numerically on numerical indicator on front panel Dielectric strength: 1500V AC, 1 min. Insulation resistance: 500V DC, 100MΩ or more Ambient temperature: 0 to 50°C Ambient humidity: 90% RH or less Enclosure: Steel case Rating plate (Name plate): 100 (H) x 70 (W) mm, white acryl Dimensions: 144 (H) x 72 (W) x 391 (D) mm, IEC (DIN) standard Mass {weight}: Approx. 2.9kg Mounting method: Flush with indoor mounting; vertical mounting. Mountable on tilted surface, angle "α" 7. Transmission functions (1) Transmission items Supervisory items: PNG host Process value, set point, control output, operation mode, alarm information, fault information, various limiter values, constants, etc. Setting operation items: Host PNG Set point, control output, operation mode, various limiter values, constants, etc. (2) Transmission setting inhibit: Parameter setting enable/inhibit can be designated by transmission from the host. Designation is done by keys on the front panel. (3) Communication interface (a) T-link: Private interface Transmission speed: 500Kbps No. of units connectable: 32 max. Transmission distance: 1km max. Transmission form: Multi-drop Control method: I/O transmission and message (b) RS-422A/485: Universal interface Transmission speed: 2400, 4800, 9600 or 19200bps configurable No. of units connectable: 31 max. Transmission distance: 1km max. Transmission form: Multi-drop Control method: Polling/selecting (c) CC data line: Private interface Transmission speed: 19.2Kbps (fixed) No. of units connectable: 15 max. Transmission distance: 500m max. Transmission form: Multi-drop Control method: Polling/selecting 8. Other functions Data protective function by pass code α=0° to 90° Finish color: Munsell N 1.5 for both front panel and case Scope of delivery: Setter and mounting bracket Item to be ordered separately: Communication cable (type PNZ) CODE SYMBOLS 1 2 3 4 5 6 7 8 9 10 5 - 0 PNG1 Description Process value input signal 1 to 5V DC 4 to 20mA DC J thermocouple 10mV DC span or K thermocouple more, with cold E thermocouple junction compenR thermocouple sation Resistance bulb, JPt 100, 3-wire, 50 °C span or more Resitance bulb, Pt100, 3-wire, 50 °C span or more A B C D E F G W Setting method L type R-L type A B Power supply 24V DC (20 to 30V DC) 100V AC (85 to 132V/47 to 63Hz AC) 200V AC (187 to 264V/47 to 63Hz AC) 1 2 3 Y T R S C Transmission function None T-link RS-422A RS-485 CC data line Note: Symbols for resistance bulb are as follows. JPt100.....JIS C 1604-1981 Pt100.....IEC Pub 751-1983 (Selection of JPt100/Pt100 possible by front key operation) 9. Operating conditions Power supply: Select from 3 types 24V DC (20 to 30V DC) 100V AC (85 to 132/47 to 63Hz AC) 200V AC (187 to 264V/47 to 63Hz AC) Power consumption: Approx. 11W (DC) Approx. 20VA (AC) 3 PNG1 OUTLINE DIAGRAM (Unit:mm) Panel thickness 8mm or less 16 144 Terminal Terminal cover 140 Support bracket 36 200min. Mounting bracket 72 355 Panel cutout +1 0 250min. +1 0 When mounting "n" units 68 4 +0.7 0 138 138 200min. When mounting 1 unit (72.2n – 4) +10 No. of units n 2 CONNECTION DIAGRAM Block terminals (M4 screw) Process value input I+ (PV) I– (SC) 11 12 13 DO (Local mode) LS 14 15 AC 16 31 Io 32 PI+ 33 PI– 34 FLT 35 AC (Pulse width input or pulse number input) AO (Compensated process value signal) AO (Set ratio output signal) AO (Set point output) AO (Squared set point output) AI, AO Common bus KPV 51 71 SV 52 72 SO 53 73 SO2 54 74 SC 55 75 56 76 SC 57 77 R-REQ H 58 78 R-ACK L 59 79 PC* 60 80 PCD 61 81 VP* G 62 82 VPD DO (FLT output) DO (High alarm) DO (Low alarm) Instrument power (24V DC, AC power) 24V power for DI, DO Instrument power (AC) Earth – – AI (External set point) CAS AI, AO common bus DO (Remote request) DI (Remote acknowledge) + Instrument power (24V DC power, AC power) + 24V power for DI, DO Note: * Symbols for AC instrument power are VPO, PCO, approx. 24V DC (0.1A max.) output. Connections for process value input terminal block 1 to 5V DC + 31 The 5th digit of code symbols A 4 to 20mA DC The 5th digit of code symbols B 4 to 20mA DC with inner DC power supply of CC-S The 5th digit of code symbols B Thermocouple 11 + – 12 + 11 The 5th digit of code symbols C,D,E,F – 12 + 11 – 12 + 11 – – 12 + 11 – 12 31 Resistance bulb 31 – + The 5th digit of code symbols G,W 31 + – 31 PC 60 5 PNG1 COMMUNICATION CONNECTOR 1 SIG GND 6 2 SHLD(SD) 7 8 RXD + 9 RXD – 3 INH 4 TXD+(T1) 1 SIG GND 6 2 SHLD(SD) Black 7 White 8 RXD + 9 RXD – 5 TXD–(T2) Green 3 INH 4 TXD+(T1) 5 TXD–(T2) Yellow Note:Symbol in ( ): T-link terminal symbol Brown Red 6 7 8 RXD + 9 RXD – 1 SIG GND 1 SIG GND 6 2 SHLD(SD) 7 3 INH 8 RXD + 4 TXD+(T1) 9 RXD – 5 TXD–(T2) LINE TERMINATION REGISTOR 2 SHLD(SD) Black 3 INH White 4 TXD+(T1) 5 TXD–(T2) Green Yellow Red Brown End station HOST MASTER CONTROLLER First station Host Termination Resistor Communication cable PNG1 PNG1 PNG1 PNG1 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office 6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan http://www.fesys.co.jp/eng Sales Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http: //www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan