HAND-HELD COMMUNICATOR < HHC > DATA SHEET FXW This instrument is a handy type communicator with builtin battery, being designed to perform facilitated communication with operater through use of "smart" type FCX series transmitter. FEATURES 1. Simple operation Adoption of large LCD display (16 digits × 4 lines) as well as menu assisted software design provides easy-touse communication interface. 2.Application to every type of device The communicator can be used with any "smart" type of FCX transmitter, FCX-A/C transmitter, FCX-AX transmitter and FCX-AII/CII, AIII transmitter. 3. On-line operation The communicator can be operated without interrupting 4 to 20mA DC signal. 4. Full variety of protective functions The communicator incorporates transmitter diagnostic function, data-write protection key, battery voltage drop alarm function, automatic power standby function, etc. 5. Optional printer Set data can be printed on an optional printer. SPECIFICATIONS Standard specifications Applicable device:"Smart" type FCX series transmitter FCX transmitter FCX-A/C transmitter FCX-AX transmitter FCX-AII/CII transmitter FCX-AIII transmitter Transmission line requirement: Line length; max 2km (0.75 to 1.25mm2 cable. For 1km and above, twist paircable is recommended.) Load resistance; 250 to 578Ω in case of FCX-1 transmitter 250 to 600Ω in case of FCX-A/C, FCX-AX, FCX-AII/CII transmitter (including cable resistance at 24V DC In case of FCX-AIII transmitter; Refer to “Load limitations“. Load capacitance; 0.22µF max. Load inductance; 3.3mH max. Separation from power line; 15cm or more (avoid parallel wiring.) Display unit: LCD, 16 digits × 4 lines Operating unit: Flat keys (32 keys), power switch, set value protection key switch Power source: Built-in nickel-cadmium battery Battery life: 24 hours (without option under standard conditions after full charge) Charger power source: 100, 115, 230V ±10% AC, 50/60Hz (as specified) Charging time: 5 hours Printer (option): Printing of 24 digits of each remote item Ambient temperature: -10 to +50°C Storage temperature: -20 to +60°C Ambient humidity: 90% RH or less Hazardous locations: Designed to meet international intrinsic safety standards. Applications have been submitted for the following. (In case of without printer only) Authorities ATEX EEx ia IIC T3 EMC Comformity: EN61326 Functional specifications Remote function:See the next page. Power alarm function: Battery voltage drop is detected and indicated by lamp flickering on display unit (Batt ALM). Set value protective function: Set value can be changed by using key switch Automatic power standby function: HHC automatically enters into standby mode when key is not accessed for more than 10 minutes (data measurement only). EDS8-47n Date Apr. 1, 2011 FXW Physical specifications Material: Polycarbonate Color: Gray Dimensions (H x W x D): 55 x 98 x 223mm (without printer) Mass: Approx. 500g (without printer) Remote functions Items Display Set Tag No. v v Model No. v v Serial No. & Software Version v — Engineering unit v v Range limit v — Measuring range v v Damping v v Output mode v — Burnout direction v v Calibration v v Output adjust — v Data v — Self diagnoses v — — Printer (In case of FXW with printer option) v External switch lock v v Transmitter display v v Linearize v v Rerange v v Saturate current v v Write protect v v History – Calibration history – Ambient temperature history v v v — Note:HHC’s version must be higher than 7.1 1− 4), for FCX–AIII. (or FXW Load limitations R [Ω] Load resistance 2000 1500 1000 When Imax is 22.5mA 1474Ω E-10.5 R= (Imax+0.9)x10-3 577Ω Communicable range with Hand-Held Communicator Operating area 500 250 0 10 16.35 10.5V 50 24V E [V] 45V Power supplay voltage E (DC) Note:Imax is the bigger one, either upper saturation current [mA] or upper burnout current [mA]. When Imax is from 20mA to 21.6mA, calculate load resistance using Imax of 21.6mA. And when Imax is from 21.7mA to 22.5mA, calculate load resistance using the formula in the figure. 2 CODE SYMBOLS 1 2 3 4 5 6 7 8 F XW 9 10 1 - A4 Description Printer Without With (explosion-proof structure is not applicable) 1 2 Charger Without 100V AC 50/60Hz 115V AC 50/60Hz 230V AC 50/60Hz 0 1 2 3 Explosion-proof structure for hazardous locations Without Intrinsic safety explosion-proof (ATEX) A K Carrying case Without With Y A Application General A 4 Use FCX, FCX-A/C, FCX-AX, FCX-AII/CII, FCX-AIII transmitter (HHC software version 7.1 or upper) Remarks The FCX-AII/CII, AIII series cannot be operated with the HHC whose software is older than version 6.0. The version of the HHC software can be upgraded by exchanging the built-in ROM. Contact the nearest Fuji Electric representative when it needs to be upgraded. (The software version can be checked on the screen display which appears when turning on HHC power supply.) OUTLINE DIAGRAM (Unit:mm) (55) (53) 98 Printer (option) 2 127 66 Battery charger connector (350) ø8 Transmission signal connector Key switch 215 power supply 42 8 8 89 CONNECTION (For example FCX-AIII transmitter) To junction terminal or instrument room Field device HHC (Connect to transmitter "+" and "–" terminals) Instrument room Junctoin terminal Terminal blok DC power source For the power supply voltage, Load resistor refer to the specification 250Ω or more "Operation area between power supply voltage and load resistance" of each field equipments. HHC HHC HHC 3 FXW The product conforms to the requirements of the Electromagnetic compatibility Directive 2004/108/EC. The applicable standards used to demonstrate compliance are :EMI (Emission) EN61326-1 : 2006 Group 1 Class 1 Frequency range MHz Limits 30 to 230 40dB (V/m) quasi peak, measured at 10m distance 230 to 1000 47dB (V/m) quasi peak, measured at 10m distance EMS (Immunity) EN55011 HHC, special cable (with clips), keys (2) OPTION Charger, carrying case, printer (based on Code symbols) EN61326-1: 2006 Table 2 (for Industrial Location) Phenomenon Electrostatic discharge Reference standard SCOPE OF DELIVERY Test value 4kV (Contact) 8kV (Air) Basic standard Performance criteria EN61000-4-2 B 80 to 1000MHz : 10V/m Electromagnetic 1.4 to 2.0GHz : 3V/m EN61000-4-3 2.0 to 2.7GHz : 1V/m field 80%AM (1kHz) A Rated power frequency magnetic field A 30A/m 50Hz EN61000-4-8 Note) Definition of performance criteria A: During testing, normal performance within the specification limits. B: During testing, temporary degradation, or loss of function or performance which is self-recovering. Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan