LINKCOM LAL0648-50

LAL0648-50
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
PIN 16-9= 1.4mH ±10% @ 10KHz/0.1V/Ser.
Leakage
Inductance:
PIN 16-9= 9.0uH ±3.0
@ 100KHz/0.1V
IInterwinding
Capacitance
PIN 1-16= 56.5 pF±18 @ 100KHz/0.1V
PIN 16-9= 16.5uH ±6.0 @ 100KHz/0.1V
PIN 5-16= 30 pF ±10
PIN 1-8= 31.5 pF ±10
PIN 1-4 to PIN 9-16= -95dB Max. @ 30KHz/2V
T.H.D
PIN 5-8 to PIN 9-16= -95dB Max. @ 30KHz/2V
PIN 1-4 = 390 mohm ±15%
D.C.R
PIN 5-8 = 2.4 ohm ±15%
PIN 16-9 = 4.6 ohm ±15%
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
Hi-POT :
PIN1-4 : PIN 16-9 = 4.21±3% :1
PIN5-8 : PIN 16-9 = 1.96±3% :1
Turn Ratio:
Dimensions Units: mm
Schematic
SEC
1.00
3.4±0.3
G
F
5.1±0.3
X DATE CODE G
B
16.6
2.5
11.4
LinkCom
15.14±0.5
Tx
LAL****
PIN1
11.90
8
Mark
12.5±0.5
1.LAL****----LAL0648
0.5TYP.
1.7±0.3
E
Form Ver. A
2. X----PRODUCT LINE
3. DATE CODE----YYWW
12.5REF.
15.6±0.5
D
11
14
7
6
SUGGESTED PADS LAYOUT
C
16
3
2
4
5
Rx
13.5±0.5
A
PRI
1
4. G----RoHS
9
LINE