LINKCOM LAL0660-50

LAL0660-50
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
PIN 16-9= 700uH ±6% @ 10KHz/0.1V/Ser.
PIN 1-4= 1.2uH ±0.2
Leakage
Inductance:
@ 100KHz/0.1V
PIN 5-8= 4.0uH ±1.0
PIN 16-9= 15uH ±2.0
PIN 1-16= 20 pF ±5.0 @ 100KHz/0.1V
PIN 5-16= 20 pF ±5.0
PIN 1-8= 15 pF ±3.0
IInterwinding
Capacitance
PIN 1-4 to PIN 9-16= -90dB Max. @ 100KHz/7.5V
T.H.D
PIN 5-8 to PIN 9-16= -90dB Max. @ 100KHz/7.5V
PIN 1-4 = 1.15 ohm ±15%
D.C.R
PIN 5-8 = 2.0 ohm ±15%
Hi-POT :
PIN 16-9 = 4.1 ohm ±15%
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
PIN16-9 : PIN 1-4 = 4±3% :1
Turn Ratio:
PIN16-9 : PIN 5-8 = 2±3% :1
Dimensions (Units: mm)
Schematic
1.00
X DATE CODE G
B
16.6
Tx
11.4
LinkCom
SEC
PIN1
8
12.5±0.5
Mark
1.LAL****----LAL0660
2. X----PRODUCT LINE
C
3. DATE CODE----YYWW
0.5TYP.
1.7±0.3
E
Form Ver. A
12.5REF.
15.6±0.5
D
11
14
7
6
11.90
SUGGESTED PADS LAYOUT
16
3
2
4
5
Rx
13.5±0.5
A
PRI
1
2.5
LAL****
15.14±0.5
3.4±0.3
G
F
5.1±0.3
4. G----RoHS
9
LINE