LINKCOM LAL0392-51

LAL0392-51
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
Electrical Specifications @25℃
OCL:
PIN 1-4= 100uH ±10% @ 10KHz/0.1V/Ser.
Leakage
Inductance:
IInterwinding
Capacitance
T.H.D
PIN 1-4= 1.0uH Max.
@ 100KHz/0.1V
PIN 1-8= 40uH Max. @ 100KHz/0.1V
PIN 1-4 to PIN 7-5= -80dB Max. @ 100KHz/3V
D.C.R:
PIN 1-4 = 1.5 ohm Max.
PIN 7-5 = 0.5 mohm Max.
PIN 1-4 to 7-5 = 44dB Min. @ 12MHz
PIN 1-4 to 7-5 = 42dB Min. @ 17MHz
LCL
PIN 1-4 to 7-5 = 30dB Min. @ 30MHz
Surge Test
PIN 1-2= 1500V @ 10/700us
Hi-POT :
Pri.-Sec.=2500V @ 2/10us
PRI. – SEC. =1500VAC/60Hz/2Seconds/1mA
Turn Ratio:
PIN1-4 : PIN 7-5 = 2.5±1% :1
Dimensions (Units: mm)
Schematic
X DATE CODE G
8.0Max
A
4.1
8.8
LAL****
LinkCom
8.5Max
1.90
B
PIN1
0.80
SUGGESTED PAD LAYOUT
Mark
10.0Max
1.LAL****----LAL0392
2. X----PRODUCT LINE
C
3. DATE CODE----YYWW
4. G----RoHS
1.9±0.5 E
SQ0.4±0.2 F
Form Ver. A
5.1Ref
7.8±0.5
D