MEANWELL HLN-40H-30

HLN-40H
40W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potentiometer
IP64 design for indoor or outdoor installations
Class 2 power unit
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp locations or outdoor application
3 years warranty
F
HLN-40H-12 A
110
M
M
IP64
SELV
( for 48V,54V only)
( except for 48V,54V )
A : IP64 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP64 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
SPECIFICATION
MODEL
DC VOLTAGE
HLN-40H-12
HLN-40H-15
HLN-40H-20
HLN-40H-24
HLN-40H-30
HLN-40H-36
HLN-40H-42
HLN-40H-48
HLN-40H-54
12V
15V
20V
24V
30V
36V
42V
48V
54V
9 ~ 15V
12 ~ 20V
14.4 ~ 24V
21.6 ~ 36V
25.2 ~ 42V
28.8 ~ 48V
32.4 ~ 54V
1.12A
0.96A
0.84A
0.75A
CONSTANT CURRENT REGION Note.4 7.2 ~12V
RATED CURRENT
3.33A
2.67A
2A
1.67A
18 ~ 30V
1.34A
RATED POWER
40W
40W
40W
40.1W
40.2W
40.3W
40.3W
40.3W
40.5W
150mVp-p
150mVp-p
150mVp-p
200mVp-p
200mVp-p
300mVp-p
300mVp-p
300mVp-p
17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
40 ~ 46V
44 ~ 53V
49 ~ 58V
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V
OUTPUT
Can be adjusted by internal potentiometer or through output cable
CURRENT ADJ. RANGE
2 ~ 3.33A
1 ~ 1.67A
0.8 ~ 1.34A
0.67 ~ 1.12A 0.58 ~ 0.96A 0.5 ~ 0.84A
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.5%
1.0%
2.0%
Note.7 1500ms, 80ms / 115VAC at full load
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
16ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5 90 ~ 305VAC
1000ms, 80ms / 230VAC at full load
16ms/115VAC at full load
127 ~ 431VDC
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
86.5%
87.5%
86.5%
0.43A / 115VAC
0.24A / 230VAC
COLD START 70A/230VAC
OVER CURRENT
88.5%
88%
0.23A / 277VAC
88.5%
Note.4
SHORT CIRCUIT
OVER VOLTAGE
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
41 ~ 49V
15 ~ 21V
18 ~ 24V
23 ~ 30V
35 ~ 43V
48 ~ 58V
28 ~ 35V
WORKING TEMP.
-40 ~ +50
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
59 ~ 68V
(Refer to "Derating Curve")
-40 ~ +80 , 10 ~ 95% RH
0.03%/
(0 ~ 40 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 independent , IP64, J61347-1, J61347-2-13
approved ; design refer to UL60950-1, TUV EN60950-1, EN60335-1
I/P-O/P:3.75KVAC
EMC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
ISOLATION RESISTANCE
PACKING
54 ~ 63V
20 ~ 95% RH non-condensing
SAFETY & WITHSTAND VOLTAGE
DIMENSION
89%
Protection type : Shut down o/p voltage, re-power on to recover
70
10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
EMC IMMUNITY
MTBF
89%
95 ~ 108%
OVER TEMPERATURE
EMC EMISSION
88.5%
<0.75mA / 277VAC
LEAKAGE CURRENT
NOTE
1.0%
FREQUENCY RANGE
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
OTHERS
0.45 ~ 0.75A
2.0%
SETUP, RISE TIME
PROTECTION
1.2 ~ 2A
2.5%
LOAD REGULATION
INPUT
1.6 ~ 2.67A
VOLTAGE TOLERANCE Note.3
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
336.5Khrs min. MIL-HDBK-217F (25 )
161*61.5*35mm (L*W*H)
0.35Kg;32pcs/12.2Kg/1.10CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:HLN-40H-SPEC 2012-03-01
HLN-40H
40W Single Output Switching Power Supply
Mechanical Specification
Case No.HLN-60A
series
Unit:mm
A Type:(HLN-40H-_A)
161
2-R2.5
35
+V(Red)
-V(Black)
21.25
SVT 18AWG 2C
SVT 18AWG 3C
6.26
35
T case: Max. Case Temperature.
2.3
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
T
case
61.5
300 20
300 20
20
21.25
6.26
IP64 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
(can access by removing the rubber stopper on the case).
B Type:(HLN-40H-_B)
161
2-R2.5
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
35
SVT 18AWG 4C
21.25
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
T
case
61.5
300 20
300 20
20
21.25
6.26
SVT 18AWG 3C
6.26
35
T case: Max. Case Temperature.
Block Diagram
fosc : 100KHz
I/P
EMI FILTER
&
RECTIFIERS
POWER
SWITCHING
PFC
CIRCUIT
RECTIFIERS
&
FILTER
+V
-V
DIM+
DIM(B Type)
O.L.P.
FG
O.T.P.
O.L.P.
PWM & PFC
CONTROL
DETECTION
CIRCUIT
O.V.P.
File Name:HLN-40H-SPEC 2012-03-01
HLN-40H
40W Single Output Switching Power Supply
Derating Curve
series
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
LOAD (%)
LOAD (%)
60
40
20
-40
-25
-10
0
15
30
40
50
60
(HORIZONTAL)
AMBIENT TEMPERATURE ( )
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
Power Factor Characteristic
Constant Current Mode
1
0 .9 9
0 .9 8
0 .9 7
0 .9 6
0 .9 5
PF
0 .9 4
0 .9 3
277VAC
0 .9 2
230VAC
0 .9 1
115VAC
0 .9
0 .8 9
0 .8 8
0 .8 7
0 .8 6
0 .8 5
50%
60%
70%
80%
90%
100%
(40W)
LOAD
EFFICIENCY vs LOAD (48V Model)
HLN-40H series possess superior working efficiency that up to 89% can be reached in field applications.
92
90
EFFICIENCY (%)
88
86
84
82
277VAC
80
230VAC
78
115VAC
76
74
72
70
10%
20%
30%
40%
50%
60% 70%
80%
90% 100%
LOAD
File Name:HLN-40H-SPEC 2012-03-01
HLN-40H
40W Single Output Switching Power Supply
series
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
(B)
Constant
Current area
100
Vo(%)
(A) Constant
Voltage area
60
(max.)
(C)
Hiccup
Protection
50
Io (%)
95
Typical LED power supply I-V curve
DIMMING OPERATION(for B-type only)
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
HLN-40H
B Type
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
Vo and Io can not be adjusted (B type)
Built-in 3 in 1 dimming function, IP64 rated. Output constant current level can be adjusted through output cable by connecting a resistance or
1 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-.
Please DO NOT connect "DIM-" to "-V".
Reference resistance value for output current adjustment (Typical)
10K
30K
40K
50K
70K
80K
90K
Single driver
100K
20K
60K
Resistance
Multiple
drivers
value
(N=driver quantity for synchronized 10K
/N 20K /N 30K /N 40K /N 50K /N 60K /N 70K /N 80K /N 90K /N 100K /N
dimming operation)
Percentage of rated current
10%
20%
30%
40%
OPEN
-----
50%
60%
70%
80%
90%
100%
95%~105%
1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
OPEN
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95%~105%
10V PWM signal for output current adjustment (Typical): Frequency range:100Hz ~ 3KHz
Duty value
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
OPEN
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95%~105%
File Name:HLN-40H-SPEC 2012-03-01
HLN-40H
40W Single Output Switching Power Supply
series
Using the built-in dimming function on B-type model can't turn the lighting fixture totally dark. Please refer to the connection method below to
achieve 0% brightness of the lighting fixture connecting to the LED power supply unit.
Dimming connection diagram for turning the lighting fixture ON/OFF :
N
FG
L
Switch
Relay
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Green/
Yellow
Brown
Blue
AC/L
HLN-40H
B Type
AC/N
DIM+
DIMV(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.
1.Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.
2.The LED lighting fixture can be turned ON/OFF by the switch.
File Name:HLN-40H-SPEC 2012-03-01