MEANWELL IPC-250

IPC-250
250W Industrial 1U ATX 12V/P4 PC Power Supply
Features :
Meet 1U rack mount system
Universal AC input / Full range
Active power factor 94%
Protections:Short circuit/Overload/Over voltage
Forced air cooling by built-in DC fan
With power good and fail signal output
Built-in remote ON-OFF control
Remote DC sense +5V and +3.3V
With +5VSB:0 ~ 2.0A max.
100% full load burn-in test
High efficiency
2 years warranty
SPECIFICATION
MODEL
IPC-250
OUTPUT NUMBER
CH1
CH2
CH3
CH4
CH5
STANDBY
DC VOLTAGE
3.3V
5V
12V
-5V
-12V
5VSB
RATED CURRENT
20A
25A
15A
0.5A
1A
2A
CURRENT RANGE
0 ~ 20A
1 ~ 25A
1 ~ 15A
0 ~ 0.5A
0.1 ~ 1A
0 ~ 2A
RATED POWER
OUTPUT
(The -5 & -12Volt combine total output shall not exceed 12W)
RIPPLE & NOISE (max.) Note.2 50mVp-p
VOLTAGE ADJ. RANGE
50mVp-p
120mVp-p
120mVp-p
50mVp-p
5.0%
5.0%
7.0%
8.0%
10%
5.0%
LINE REGULATION
1.0%
1.0%
1.0%
2.0%
2.0%
1.0%
LOAD REGULATION
5.0%
5.0%
7.0%
8.0%
10%
5.0%
800ms, 20ms/230VAC
HOLD TIME (Typ.)
16ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
75%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
4A/115VAC
LEAKAGE CURRENT(max.)
OVER LOAD
40A/115VAC
3mA/240VAC
2500ms, 20ms/115VAC at full load
16ms/115VAC at full load
2A/230VAC
80A/230VAC
105 ~ 150% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
+3.3V, +5V: 110% ~ 140% of rated voltage ; +12V:13.2V ~ 16V
Protection type : Shut down o/p voltage, re-power on to recover
SHORT CIRCUIT
All output equipped with short circuit
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION
100mVp-p
CH2 : 5.05 ~ 5.5V
VOLTAGE TOLERANCE Note.3
SETUP, RISE TIME
INPUT
250W continue. +5V,+3.3V,+12V combine total power output shall not exceed 230W. (The +5 & +3.3Volt combine total output shall not exceed 150W)
POWER GOOD SIGNAL
POWER FAIL SIGNAL
PS-ON INPUT SIGNAL
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
The TTL compatible signal out with 100ms to 500ms delay after power set up
The TTL compatible signal will go down at least 1ms before +5V below 4.75V
Power off: PS-ON = "Hi" or ">2V" ; Power on: PS-ON = "Low" or "<0.5V"
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 10 ~ 95% RH
0.05% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:50M Ohms / 500VDC / 25 / 70% RH
SAFETY & ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B, Design refer to FCC part 15 Class B
(Note 4)
Compliance to EN61000-3-2,-3
HARMONIC CURRENT
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
EMS IMMUNITY
MTBF
CONNECTOR
OTHERS
COOLING
DIMENSION
PACKING
NOTE
94.1K hrs min.
MIL-HDBK-217F (25
)
ATX main power connector * 1ea; +12V power connector * 1ea
Peripheral power connector * 3ea; Floppy drive power connector * 1ea
Forced air ventilation by 4cm DC fan
240*83*40mm (L*W*H)
1.44Kg; 10pcs/15.4Kg/0.89CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Load regulation is measured from 20% to 100% max. Load.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name: IPC-250-SPEC 2010-10-18
IPC-250
250W Industrial 1U ATX 12V/P4 PC Power Supply
Mechanical Specification
Case No. IPC-250
Unit:mm
4.75
40
19.5
SVR
83
72.7
Air flow
direction
7
M3
4
2-M3
240
PIN1
(A)
PIN11
+3.3V(ORANGE)
+3.3V(ORANGE)
GND(BLACK)
+5V(RED)
GND(BLACK)
+5V(RED)
GND(BLACK)
PG(GRAY)
+5VSB(PURPLE)
+12V(YELLOW)
+3.3V(ORANGE)
-12V(BLUE)
GND(BLACK)
PS-ON(GREEN)
GND(BLACK)
GND(BLACK)
GND(BLACK)
-5V(WHITE)
+5V(RED)
+5V(RED)
(WIRE OUTPUT OF PCB, 18AWG)
L=450mm 10mm
PIN10 PIN20
(B)
+5VDC(RED)
GND(BLACK)
GND(BLACK)
+12V(YELLOW)
4
3
2
1
(B)
+5VDC(RED)
GND(BLACK)
GND(BLACK)
+12V(YELLOW)
4
3
2
1
(B)
+5VDC(RED)
GND(BLACK)
GND(BLACK)
+12V(YELLOW)
4
3
2
1
L=150mm
L=150mm 10mm
(A)MOLEX 39-01-2200 or equivalent
L=150mm
(C)
+5VDC(RED)
GND(BLACK)
GND(BLACK)
+12V(YELLOW)
+12V(YELLOW)
3
4
+12V(YELLOW)
(D)
GND(BLACK)
1
2
GND(BLACK)
(B)MOLEX 8981-04P or equivalent
(C)AMP 171822-4 or equivalent
L=150mm
(D)MOLEX 39-01-2040 or equivalent
1
2
3
4
L=440mm 10mm
File Name: IPC-250-SPEC 2010-10-18
IPC-250
250W Industrial 1U ATX 12V/P4 PC Power Supply
Block Diagram
fosc : 100KHz
+5VSB
DETERCTION
CIRCUIT
RECTIFIERS
&
FILTER
POWER SWITCHING
PWM CONTROL
+5VSB
RECTIFIERS
&
FILTER
MA &
CONTROL
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
RECTIFIERS
&
P.F.C.
POWER
SWITCHING
+3.3V
RECTIFIERS
&
FILTER
+5V,+12V,-5V,-12V
COM
P.G. DETECTION
CIRCUIT
FG
O.L.P.
PWM
CONTROL
PG
DETECTION &
O.V.P. CIRCUIT
PS/ON
CONTROL
Derating Curve
PS/ON
Output Derating VS Input Voltage
100
100
90
80
80
70
LOAD(%)
LOAD (%)
60
40
20
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
60
50
40
90
100
115
135
155
230
264
INPUT VOLTAGE (V) 60Hz
File Name: IPC-250-SPEC 2010-10-18