HDP-190 190W Dual Output with PFC Function Features : Universal AC input / Full range Built-in active PFC function, PF 0.94 High efficiency up to 86% Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection 1U low profile 36mm Conformal coated ZVS technology to reduce power dissipation LED indicator for power on 3 years warranty SPECIFICATION MODEL HDP-190 OUTPUT NUMBER V1 DC VOLTAGE +3.8V +2.8V RATED CURRENT 33A 20A CURRENT RANGE (max.) 0 ~ 40A RATED POWER 181.4W (typ.) OUTPUT POWER (max.) OUTPUT V2 0 ~ 22A 192W (max.) 192W continue. V1 total power output shall not exceed 160W (max. 40A) ; V2 total power output shall not exceed 66W (max. 22A) (The V1 & V2 combine total power output shall not exceed 192W) RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p VOLTAGE ADJ. RANGE Note.6 3.6 ~ 4V VOLTAGE TOLERANCE Note.3 2.0% 2.5 ~ 3V 2.0% LINE REGULATION 0.5% LOAD REGULATION 2.0% 0.5% 2.0% SETUP, RISE TIME 1000ms, 50ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz INPUT 2500ms, 50ms/115VAC at full load 127 ~ 370VDC POWER FACTOR (Typ.) PF 0.94/230VAC EFFICIENCY (Typ.) AC CURRENT (Typ.) 86% 2.7A/115VAC 1.1A/230VAC INRUSH CURRENT (Typ.) 30A/115VAC 45A/230VAC LEAKAGE CURRENT <2mA / 240VAC V1+V2: 105 ~ 150% max. output power ; or V2: 125 ~ 170% rated current OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. PF 0.98/115VAC at full load Protection type: Hiccup mode, recovers automatically after fault condition is removed V2: 3.22 ~ 3.78V V1: 4.37 ~ 5.13V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) detect on heatsink of power transistor Protection type : Shut down o/p voltage, re-power on to recovery -30 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY OTHERS I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A MTBF 111.3K hrs min. DIMENSION 215*115*36mm (L*W*H) 0.95Kg; 15pcs/15.3Kg/0.7CUFT PACKING NOTE UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Output voltage between V1 and V2 should be higher than 0.8V(V1-V2 0.8V). File Name:HDP-190-SPEC 2011-12-28 HDP-190 190W Dual Output with PFC Function Mechanical Specification Case No.206A Unit:mm 215 204.5 97.5 150 32.5 24 15.85 SVR1 Terminal Pin No. Assignment : SVR1: V1(+3.8V)ADJ. SVR2: V2(+2.8V)ADJ. 115 108 Assignment V2(+2.8V) V1(+3.8V) COM 44.75 34.4 95 Assignment Pin No. AC/L 4,5 AC/N 6,7 8,9,10,11 FG 10 32.5 50 Pin No. 1 2 3 16 3.5 9.5 135 8.3 11 10 LED 9 8 7 4-M4 L=5mm 6 SVR2 5 4 3 2 5-M3 L=3mm 1 15 215 150 32.5 12.5 36 16max. 4-M4 L=5mm Block Diagram ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P PFC fosc : 65KHz PWM fosc : 80KHz RECTIFIERS & PFC POWER SWITCHING O.T.P. O.L.P. RECTIFIERS & FILTER RECTIFIERS & FILTER DETECTION CIRCUIT FG PFC CONTROL +V1 COM PWM CONTROL O.V.P. +V2 O.L.P. PWM CONTROL DETECTION CIRCUIT O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 50 LOAD(%) LOAD (%) 60 40 20 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 95 100 115 130 145 165 185 205 225 245 264 INPUT VOLTAGE (V) 60Hz File Name:HDP-190-SPEC 2011-12-28