PID-250 250W Isolated Dual Output with PFC Function Features : Universal AC input / Full range Optional L-Bracket and cover Isolated output & GND for CH1,CH2 Built-in active PFC function, PF>0.92 Protections:Short circuit / Overload / Over voltage / Over temperature Remote control for CH1 Peak load 170% for CH1 within 10 sec. Cooling by free air convection 100% full load burn-in test 3 years warranty SPECIFICATION MODEL PID-250A PID-250D CH1 CH2 CH1 CH2 CH1 CH2 CH1 CH2 DC VOLTAGE 12V 5V 24V 5V 36V 5V 48V 5V RATED CURRENT 15A(Peak 20A) 5A 9.4A(Peak 16.7A) 5A 6.3A(Peak 11.1A) 5A 4.7A(Peak 8.4A) 5A 0 ~ 15A 0 ~ 9.4A (Peak 16.7A) 0 ~ 5A 0 ~ 6.3A (Peak 11.1A) 0 ~ 4.7A (Peak 8.4A) 0 ~ 5A Note.6 (Peak 20A) 205W RATED POWER 250.6W 0 ~ 5A 251.8W 0 ~ 5A 250.6W RIPPLE & NOISE (max.) Note.2 120mVp-p 50mVp-p 150mVp-p 50mVp-p 200mVp-p 50mVp-p 200mVp-p 50mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.25V 2.0% 21.6 ~ 26.4V 2.0% 4.75 ~ 5.25V 2.0% 32.4 ~ 39.6V 2.0% 4.75 ~ 5.25V 2.0% 43.2 ~ 52.8V 2.0% 4.75 ~ 5.25V 2.0% 10.8 ~ 13.2V VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 2.0% 1.0% 2.0% 1.0% 2.0% 1.0% 2.0% 2500ms, 60ms/115VAC SETUP, RISE TIME 1200ms, 60ms/230VAC 30ms at full load HOLD UP TIME (Typ.) VOLTAGE RANGE INPUT PID-250C OUTPUT NUMBER CURRENT RANGE OUTPUT PID-250B Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR PF 0.92/230VAC EFFICIENCY(Typ.) 83% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 3A/115VAC LEAKAGE CURRENT PF 0.97/115VAC at full load 86% 86% 86% 1.5A/230VAC COLD START 58A/230VAC <3.5mA / 240VAC CH1: 105 ~ 170% rated output power Normally work within 10 sec and then shut down, re-power on to recover Over 180% rated power or short circuit, constant current limiting within 10 sec and then shut down, re-power on to recover OVERLOAD CH2: 101 ~ 150% rated output power PROTECTION OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed 40 ~ 48V 5.5~ 6.75V 54 ~ 64.8V 5.5 ~ 6.75V 13.8 ~ 16.2V 5.5 ~ 6.75V 27.6 ~ 32.4V 5.5 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover for CH1 ; Hiccup mode, recovers automatically afer fault condition is removed for CH2(by zener diode clamp) OVER TEMPERATURE FUNCTION REMOTE CONTROL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE 105 5 detect on heatsink of power transistors Protection type : Shut down o/p voltage(CH1), recovers automatically after temperature goes down CN52 : Open=CH1 & CH2 power on ; Short = CH1 power off, CH2 power on; when CH2 is malfunction, CH1 will be shut down -20 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2, heavy industry level, criteria A 150.4Khrs min. MIL-HDBK-217F (25 ) PCB:222*95*40mm (L*W*H) ; with optional CASE:250*105.4*53mm (L*W*H) PCB:0.74Kg; 18pcs/14.3Kg/0.88CUFT ; with optional CASE:1.6Kg; 9pcs/15.4Kg/0.61CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltage. Please check the derating curve for more details. 6. Peak current should reduce to 150% of rated value if the input voltage <110VAC. 7. Heat Sink HS1,HS2,HS3 can not be shorted. File Name:PID-250-SPEC 2011-08-18 PID-250 250W Isolated Dual Output with PFC Function(Open Frame Type) Mechanical Specification Unit:mm 222 212 5 CN1 CN51 FS1 15cm HS3 Assignment COM1 V1 COM2 V2 Pin No. 1,2,3 4,5,6 7,8 9,10 SVR2 CN52 130 Assignment FG No Pin AC/N AC/L Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent DC Output Connector (CN51) : JST B10P-VH or equivalent 2 1 5 3.5 6 95 1 2 3 4 5 6 7 8 9 10 SVR1 85 FAN T6.3A/250V 4- Pin No. 1 2,4 3 5 HS2 1 2 3 4 5 AC FUSE 18CFM min. AC Input Connector (CN1) : JST B5P-VH or equivalent 5 HS1 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 3max. 40 Remote ON/OFF Connector(CN52):JST B2B-XH or equivalent Pin No. Status PIN1,2 (Short) V1: OFF V2: ON PIN1,2 (Open) V1: ON V2: ON SVR1 SVR2 For CH1 For CH2 Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent HS1,HS2,HS3 can not be shorted PFC fosc : 100KHz PWM fosc : 100KHz Block Diagram I/P EMI FILTER & RECTIFIERS PFC CIRCUIT RECTIFIERS & FILTER POWER SWITCHING O.L.P. FG CH1 GND1 COSTANT CURRENT LIMITING & DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. R.C. (CN52) RECTIFIERS & FILTER POWER SWITCHING CH2 GND2 DETECTION CIRCUIT Derating Curve Output Derating VS Input Voltage With 18CFM FAN 100 100 90 80 80 70 Convection 50 LOAD (%) LOAD (%) 60 40 20 -20 -10 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 110 115 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:PID-250-SPEC 2011-08-18 250W Isolated Dual Output with PFC Function(Open Frame Type) Mechanical Specification 7.5 Case No.965A 25.5 AC Input Connector (CN1) : JST B5P-VH or equivalent Pin No. 1 2,4 3 5 53 2-M4 15 R2 .25 4.5 23 235 FAN 52 1 2 3 4 5 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent SVR1 5cm 2 1 CN52 .25 SVR2 R2 1 2 3 4 5 6 7 8 9 10 Pin No. 1,2,3 4,5,6 7,8 9,10 Assignment COM1 V1 COM2 V2 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Remote ON/OFF Connector(CN52):JST B2B-XH or equivalent CN51 10 105.4 10 CN1 2- 4.5 Assignment FG No Pin AC/N AC/L DC Output Connector (CN51) : JST B10P-VH or equivalent 250 45 Unit:mm 235 7.5 18CFM min. PID-250 Pin No. Status PIN1,2 (Short) V1: OFF V2: ON PIN1,2 (Open) V1: ON V2: ON SVR1 SVR2 For CH1 For CH2 Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent 4-M4 File Name:PID-250-SPEC 2011-08-18 PID-250 250W Isolated Dual Output with PFC Function(Enclosed Type) Block Diagram I/P PFC fosc : 100KHz EMI FILTER & RECTIFIERS PFC CIRCUIT O.L.P. FG RECTIFIERS & FILTER POWER SWITCHING CH1 GND1 COSTANT CURRENT LIMITING & DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. R.C. (CN52) RECTIFIERS & FILTER POWER SWITCHING CH2 GND2 DETECTION CIRCUIT Derating Curve Output Derating VS Input Voltage Ta=25 100 100 With 18CFM FAN 90 80 80 70 40 LOAD (%) LOAD (%) 60 Convection 30 20 -20 -10 0 10 20 25 30 40 50 AMBIENT TEMPERATURE ( ) 60 65 70 (HORIZONTAL) 60 50 40 90 100 110 115 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:PID-250-SPEC 2011-08-18