MEANWELL QP

QP-1000
1000W Quad Output Power Supply
Features :
ry
Universal AC input / Full range
AC input active surge current limiting
Built-in active PFC function, PF>0.95
na
Protections: Short circuit / Overload / Over voltage/Over temperature
Forced air cooling by built-in DC Fan
Built-in remote ON-OFF function for CH3,CH4 and the whole unit
Isolate output
Built-in remote sense function(CH3,CH4)
Built-in external voltage control function(CH3,CH4)
Built-in output current monitor signal(CH3,CH4)
SPECIFICATION
MODEL
QP-1000
OUTPUT NUMBER
CH1
CH2
CH3
DC VOLTAGE
12V
5V
24V
24V
RATED CURRENT
8.4A
6A
12.5A
25A
CURRENT RANGE
0 ~ 8.4A
0 ~ 6A
0 ~ 12.5A
0 ~ 25A
300W
600W
80mVp-p
100mVp-p
200mVp-p
4.5 ~ 5.5V
21.5 ~ 26.5V
21.5 ~ 26.5V
RATED POWER (convection)
1000W(max.)
RIPPLE & NOISE (max.) Note.2 120mVp-p
10.8 ~ 13.2V
VOLTAGE ADJ. RANGE
mi
OUTPUT
130.8W(max.)
CH4
REMOTE PROGRAMMING (PV) CH3,CH4 10% ~ 120% adjustable by 0.5 ~ 6VDC external control
VOLTAGE TOLERANCE Note.3
2.0%
2.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
1.0%
1500ms, 50ms/230VAC
SETUP, RISE TIME
16ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
16ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
EFFICIENCY(Typ.)
PF 0.95/230VAC
86%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
12A/115VAC
6A/230VAC
COLD START 25A/115VAC
LEAKAGE CURRENT
<2mA / 240VAC
PF 0.97/115VAC at full load
40A/230VAC
eli
INPUT
Note.5 90 ~ 264VAC
1500ms, 50ms/115VAC at full load
OVERLOAD
105 ~ 135% rated output power
CH1, CH2 : Protection type : Shut down o/p voltage, re-power on to recover
CH3, CH4 : Protection type : Constant current limiting, unit will shut down after 3 sec., re-power on to recover
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
REMOTE CONTROL
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
EMC
(Note 4)
OTHERS
NOTE
30 ~ 34.8V
30~ 34.8V
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Turn ON/OFF CH3,CH4 and the whole power supply
RC+/RC-: Short , Power ON ; RC+/RC-: Open , Power OFF
Signal provides an output of 0 ~ 5V which applies over 10 ~ 100% of rated load.
CURRENT MONITOR
OUTPUT VOLTAGE EXTERNAL CONTROL Please see the Function Manual
-20 ~ +70 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
SAFETY &
5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
75
5 detect on heatsink of power transistors
Pr
FUNCTION
13.8 ~ 16.2V
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45 )
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL60950-1,TUV EN60950-1
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2, EN61204-3
MTBF
K hrs min. MIL-HDBK-217F (25
278*177.8*63.5mm (L*W*H)
Kg
DIMENSION
PACKING
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:QP-1000-SPEC 2008-12-05
QP-1000
1000W Quad Output Power Supply
Mechanical Specification
Unit:mm
ry
Case No.
278
245
8-M4(Both Sides) L=8mm
63.5
38
12.5
18
18
Pin No.
1
2
3
1
2
3
8 ADJ LED
4
5
6
ADJ2 ADJ1 LED LED
+
1 7
2 8
ADJ LED
2
3
TB1
1
CN1
10
9
8
7
24
+
+
13
13
mi
AC Input Terminal Pin
No. Assignment (TB1)
7
TB2
CN2
1
2
+
CN3
10
Air flow
direction
13max.
9
162
4-M4 L=5mm
11
7.9
na
245
16max.
DC Output Terminal Pin No. Assignment (TB2)
Assignment
FG
AC/N
AC/L
Pin No.
1,2
3,4
5
6
Assignment
+V4
-V4
+V1
-V1
Pin No.
7
8
9
10
Assignment
-V2
+V2
+V3
-V3
Control Pin No. Assignment(CN1) for CH3: HRS DF11-8DP-2DS or equivalent
1
2
3
4
Assignment
+S
-S
+RC
PS
Pin No.
5
6
7,8
Assignment
PV
Im
G
Mating Housing
Terminal
HRS DF11-8DS
or equivalent
HRS DF11-**SC
or equivalent
eli
Pin No.
+S : +Remote Sensing
PV : Voltage Control
-S : -Remote Sensing
Im : Output Current Monitor
+RC : +Remote OF/OFF
G : GND
PS : Reference Voltage Terminal
Control Pin No. Assignment(CN2): HRS DF11-4DP-2DS or equivalent
Pin No.
1
2
3,4
Assignment
VCC
+RC
COM
Mating Housing
Terminal
HRS DF11-4DS
or equivalent
HRS DF11-**SC
or equivalent
Pr
+RC : +Remote OF/OFF
VCC : 12V/0.1A auxiliary output for remote control
Control Pin No. Assignment(CN3) for CH4: HRS DF11-8DP-2DS or equivalent
Pin No.
1
2
3
4
Assignment
+S
-S
+RC
PS
Pin No.
5
6
7,8
Assignment
PV
Im
G
Mating Housing
Terminal
HRS DF11-8DS
or equivalent
HRS DF11-**SC
or equivalent
+S : +Remote Sensing
PV : Voltage Control
-S : -Remote Sensing
Im : Output Current Monitor
+RC : +Remote OF/OFF
G : GND
PS : Reference Voltage Terminal
File Name:QP-1000-SPEC 2008-12-05
QP-1000
1000W Quad Output Power Supply
ry
Block Diagram
REMOTE
CONTROL
FAN
AUX
POWER
RECTIFIERS
&
FILTER
RECTIFIERS
&
PFC
I/P
REMOTE
CONTROL
RECTIFIERS
&
FILTER
POWER
SWITCHING
O.T.P
Aux Power
12V/0.1A
+S
+V3
-V3
-S
DETECTION
CIRCUIT
PWM
CONTROL
PFC
CONTROL
FG
RECTIFIERS
&
FILTER
POWER
SWITCHING
na
EMI
FILTER
RC
RC(V3)
+S
O.V.P.
O.L.P.
PWM
CONTROL
mi
DETECTION
CIRCUIT
eli
100
80
50
40
20
-20
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
O.L.P.
RECTIFIERS
&
FILTER
+V1
RECTIFIERS
&
FILTER
+V2
-V1
-V2
O.V.P.
O.V.P.
Output Derating VS Input Voltage
Ta=25
100
90
80
70
LOAD (%)
LOAD (%)
Pr
60
RC(V4)
O.V.P.
MA
&
CONTROL
PWM
CONTROL
Derating Curve
-S
REMOTE
CONTROL
MA
&
CONTROL
POWER
SWITCHING
O.L.P.
+V4
-V4
60
50
40
90
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-1000-SPEC 2008-12-05
QP-1000
Quad Output Power Supply
ry
Function Manual
1.Remote ON/OFF
The PSU by using the "Remote ON/OFF" function
A. For CH3 (CN1) or CH4 (CN3)
SW
+RC
G
Output Status
SW ON (Short)
ON
SW OFF (Open)
OFF
na
Between +RC(pin3) and G(pin7,8)
B. For CH1 ~ CH4 (CN2)
SW
+RC
COM
Between +RC(pin1) and COM(pin2,4)
ON
SW OFF (Open)
mi
SW ON (Short)
Output Status
OFF
2.External Voltage Control by CH3,CH4
Vout
120
+S
LOAD
80
Non-Linear
-S
PV
1~6V
Pr
-S
60
40
20
1
2
3
4
5
EXTERNAL VOLTAGE (DC)
6
V
OUTPUT CURRENT (%)
-V
eli
-V
100
100
+V
OUTPUT VOLTAGE (%)
+V
80
60
40
20
20
40
60
80
100
120
V
OUTPUT VOLTAGE (%)
File Name:QP-1000-SPEC 2008-12-05